MC10ELT22, MC100ELT22
www.onsemi.com
3
Table 3. MAXIMUM RATINGS
Symbol Parameter Condition 1 Condition 2 Rating Units
V
CC
Positive Power Supply GND = 0 V 7 V
V
IN
Input Voltage GND = 0 V GND + 0.025 v V
I
v V
CC
− 0.025
V
I
out
Output Current Continuous
Surge
50
100
mA
mA
T
A
Operating Temperature Range −40 to +85 °C
T
stg
Storage Temperature Range −65 to +150 °C
q
JA
Thermal Resistance (Junction−to−Ambient) 0 lfpm
500 lfpm
8 SOIC
8 SOIC
190
130
°C/W
°C/W
q
JC
Thermal Resistance (Junction−to−Case) Standard Board 8 SOIC 41 to 44 °C/W
q
JA
Thermal Resistance (Junction−to−Ambient) 0 lfpm
500 lfpm
8 TSSOP
8 TSSOP
185
140
°C/W
°C/W
q
JC
Thermal Resistance (Junction−to−Case) Standard Board 8 TSSOP 41 to 44 ± 5% °C/W
T
sol
Wave Solder <2 to 3 sec @ 248°C 265 °C
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
Table 4. 10ELT SERIES PECL DC CHARACTERISTICS V
CC
= 5.0 V; GND = 0.0 V (Note 2)
Symbol
Characteristic
−40°C 25°C 85°C
Unit
Min Typ Max Min Typ Max Min Typ Max
I
CC
Power Supply Current 22 22 22 mA
V
OH
Output HIGH Voltage (Note 3) 3920 4010 4110 4020 4105 4190 4090 4185 4280 mV
V
OL
Output LOW Voltage (Note 3) 3050 3200 3350 3050 3210 3370 3050 3227 3405 mV
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm.
2. Output parameters vary 1:1 with V
CC
. V
CC
can vary ± 0.25 V.
3. Outputs are terminated through a 50 W resistor to V
CC
− 2.0 V.
Table 5. 100ELT SERIES PECL DC CHARACTERISTICS V
CC
= 5.0 V; GND = 0.0 V (Note 4)
Symbol
Characteristic
−40°C 25°C 85°C
Unit
Min Typ Max Min Typ Max Min Typ Max
I
CC
Power Supply Current 22 22 22 mA
V
OH
Output HIGH Voltage (Note 5) 3915 3995 4120 3975 4045 4120 3975 4050 4120 mV
V
OL
Output LOW Voltage (Note 5) 3170 3305 3445 3190 3295 3380 3190 3295 3380 mV
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm.
4. Output parameters vary 1:1 with V
CC
. V
CC
can vary ± 0.25 V.
5. Outputs are terminated through a 50 W resistor to V
CC
− 2.0 V.