Test Test methods/conditions Requirement
Solderability IEC 60068-2-20, test Ta,
method 1 with modified conditions for
lead-free solder alloys: 245 °C, 3 s:
After dipping the terminals to a depth of
approximately 3 mm from the body in a
soldering bath of 245 °C for 3 s, the
terminals shall be visually examined.
The inspection shall be
carried out under adequate
light with normal eyesight or
with the assistance of a
magnifier capable of giving
a magnification of 4 to
10 times. The dipped
surface shall be covered
with a smooth and bright
solder coating with no more
than small amounts of
scattered imperfections
such as pinholes or
un-wetted or de-wetted
areas. These imperfections
shall not be concentrated in
one area.
Resistance to soldering
heat
IEC 60068-2-20, test Tb, method 1A,
260 °C, 10 s:
Each lead shall be dipped into a solder
bath having a temperature of 260 ±5 °C
to a point 2.0 to 2.5 mm from the body
of the specimen, be held there for
10 ±1 s and then be stored at room
temperature and normal humidity for
1 to 2 h.
The change of V
V
shall be measured
and the specimen shall be visually
examined.
|V/V (1 mA)| 5%
No visible damage
Tensile strength IEC 60068-2-21, test Ua1
After gradually applying the force
specified below and keeping the unit
fixed for 10 s, the terminal shall be
visually examined for any damage.
Force for wire diameter:
0.6 mm = 10 N
0.8 mm = 10 N
1.0 mm = 20 N
|V/V (1 mA)| 5%
No break of solder joint,
no wire break
Leaded varistors B722*
AdvanceD-MP, S10 series
Page 7 of 22Please read Cautions and warnings and
Important notes at the end of this document.
Test Test methods/conditions Requirement
Vibration IEC 60068-2-6, test Fc, method B4 |V/V (1 mA)| 5%
No visible damage
Frequency range:
Amplitude:
Duration:
Pulse:
10 … 55 Hz
0.75 mm or 98 m/s
2
6 h (3 · 2 h)
sine wave
After repeatedly applying a single
harmonic vibration according to the
table above.
The change of V
V
shall be measured
and the specimen shall be visually
examined.
Bump IEC 60068-2-29, test Eb |V/V (1 mA)| 5%
No visible damage
Pulse duration:
Max. acceleration:
Number of bumps:
Pulse:
6 ms
400 m/s
2
4000
half sine
Fire hazard IEC 60695-11-5 (needle flame test)
Severity: vertical 10 s
5 s max.
Note:
UCT = Upper category temperature
LCT = Lower category temperature
R
ins
= Insulation resistance
Leaded varistors B722*
AdvanceD-MP, S10 series
Page 8 of 22Please read Cautions and warnings and
Important notes at the end of this document.
v/i characteristics
v = f (i) - for explanation of the characteristics refer to "General technical information", 1.6.3
A = Leakage current, B = Protection level } for worst-case varistor tolerances
SIOV-S10 ... E2K1
Leaded varistors B722*
AdvanceD-MP, S10 series
Page 9 of 22Please read Cautions and warnings and
Important notes at the end of this document.

B72210P2171K101

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Varistors 10mm / 175v
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union