MINI MCR-SL-U-UI
101744_en_05 PHOENIX CONTACT 4
4 Technical data
Input
Configurable/programmable Yes, preconfigured
Voltage input signal 0 V ... 24 V
0 V ... 30 V
Max. voltage input signal 50 V DC
Input resistance of voltage input Approx. 125 k (0 ... 24 V)
Approx. 155 k (0 ... 30 V)
Output
Voltage output signal 0 V ... 10 V
0 V ... 5 V
1 V ... 5 V
2 V ... 10 V
Max. voltage output signal 12.5 V
Non-load voltage 12.5 V
Current output signal 0 mA ... 20 mA
4 mA ... 20 mA
Max. current output signal 28 mA
Configurable/programmable Yes, preconfigured
Short-circuit current 22 mA
Load/output load voltage output > 10 k
Ripple < 20 mV
PP
(at 500 )
Load/output load current output < 500 (at 20 mA)
Supply
Nominal supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC (to bridge the supply voltage, the DIN rail connector (ME
6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used. It can be
snapped onto a 35 mm DIN rail according to EN 60715)
Max. current consumption < 19 mA (at 24 V DC incl. load)
Power consumption < 450 mW
General data
Limit frequency (3 dB) Approx. 100 Hz
Measuring principle Signal isolator
Maximum transmission error < 0.1 % (of final value)
< 0.4 % (Without adjustment)
Temperature coefficient, typical < 0.002 %/K
Maximum temperature coefficient < 0.01 %/K
Step response (10-90%) Approx. 3.5 ms
Electrical isolation Basic insulation according to EN 61010
Surge voltage category II
Mounting position Any
Degree of protection IP20
Pollution degree 2
Rated insulation voltage 50 V AC/DC
Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
Dimensions W / H / D 6.2 mm / 93.1 mm / 102.5 mm
Type of housing PBT green
MINI MCR-SL-U-UI
101744_en_05 PHOENIX CONTACT 5
Connection data Screw connection Spring-cage conn.
Conductor cross section, solid 0.2 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm²
Conductor cross section, stranded 0.2 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm²
Stripping length 12 mm 8 mm
Ambient conditions
Ambient temperature (operation) -20 °C ... 65 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Conformance with EMC Directive 2004/108/EC
Noise immunity according to EN 61000-6-2
Noise emission according to EN 61000-6-4
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized
UL, USA / Canada Class I, Div. 2, Groups A, B, C, D T5
Shipbuilding GL EMC 2 D
MINI MCR-SL-U-UI
101744_en_05 PHOENIX CONTACT 6
5 Safety regulations and installation notes
5.1 Installation notes
The category 3 device is suitable for installation in the
zone 2 potentially explosive area. It fulfills the require-
ments of EN60079-0:2009 and EN60079-15:2010.
Installation, operation, and maintenance may only be car-
ried out by qualified electricians. Follow the installation in-
structions described. When installing and operating the
device, the applicable regulations and safety directives
(including national safety directives), as well as general
technical regulations, must be observed. The technical
data is provided in this package slip and on the certifi-
cates (conformity assessment, additional approvals
where applicable).
It is not permissible to open or modify the device. Do not
repair the device yourself but replace it with an equivalent
device. Repairs may only be carried out by the manufac-
turer. The manufacturer is not liable for damage resulting
from violation.
The IP20 degree of protection (IEC60529/EN60529) of
the device is intended for use in a clean and dry environ-
ment. Do not subject the device to any load that exceeds
the described limits.
The device is not designed for use in atmospheres with a
danger of dust explosions.
5.2 Installation in the Ex area (zone 2)
Observe the specified conditions for use in potentially ex-
plosive areas.
The device must be installed in a housing (control or dis-
tributor box) which meets the requirements of EN 60079-
15 and provides at least IP54 (EN 60529) degree of pro-
tection.
During installation and when connecting the supply and
signal circuits, observe the requirements of EN 60079-
14. Devices may only be connected to circuits in zone 2 if
they are suitable for operation in Ex zone 2 and for the
prevailing conditions at the place of use.
In potentially explosive areas, terminals may only be
snapped onto or off the DIN rail connector and wires may
only be connected or disconnected when the power is
switched off.
The device must be stopped and immediately removed
from the Ex area if it is damaged, has been subjected to
an impermissible load, has been stored incorrectly, or if it
malfunctions.
You can download the latest documents for these devic-
es from www.phoenixcontact.net/catalog.

2810078

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules MINI MCR-SL-U-UI- SP-NC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet