APRIL 2013 - REVISED NOVEMBER 2013
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
TISP9110MDM Overvoltage Protector
APPLICATIONS INFORMATION
SLIC
-V
BAT
SLIC
PROTECTOR
TISP9110MDM
C1
220 nF
Tip
Ring
D1
C2
220 nF
+V
BAT
Overcurrent
Protection
Figure 4. Typical Application Diagram
GR-1089-CORE Intra Building
Overcurrent Protection 1
F1b
B0500T
F1a
B0500T
ITU-T K.20 (Basic)
Overcurrent Protection 2
MF-SM013-250
+ t°
MF-SM013-250
+ t°
ITU-T K.20 (Enhanced 10/700 μs 4 kV)
Overcurrent Protection 3
*55 Ω CPTC
*55 Ω CPTC
+ t°
+ t°
* Specific CPTC can withstand
10/700 4 kV without primary protector.
Figure 5. Typical Overcurrent Protection
“TISP” is a registered trademark of Bourns Ltd., a Bourns Company, in the United States and other countries, except that “TISP” is a registered trademark of Bourns, Inc. in China.