Data Sheet 10 Rev. 1.2, 2004-01-01
TLE 4473 GV55
Inhibit Input INH2
Turn-on Voltage V
INH2 ON
––2.3 V V
Q2
on
Turn-off Voltage
V
INH2 OFF
0.65 ––V V
Q2
off
H-input current
I
INH2 ON
-1 3.2 6 µA V
INH2
= 5.0 V (see
Page 13)
L-input current
I
INH2 OFF
-1 0.1 1 µA0 V < V
INH2
< 0.8 V
Watchdog and Reset Timing D2
Charge current
I
DC2
6.5 9.0 12.5 µA V
D2
= 1 V
Discharge current
I
DD2
2.0 3.5 5.0 µA V
D2
= 1 V
Upper timing
threshold
V
DU2
1.5 1.85 2.4 V
Lower timing
threshold
V
DL2
0.30.40.5V
Saturation Voltage
V
D2,SAT
––100 mV V
Q2
< V
RT2
Watchdog trigger
time
T
WI,tr
34 42 51 ms C
D2
= 100 nF
Reset delay time
T
RD2
15 20 25 ms C
D2
= 100 nF
Reset reaction time
T
rr
––5.0 µs C
D2
= 100 nF
Reset Output RO2
Reset switching
threshold
V
RT2
4.5 4.65 4.8 V
V
RT2
/V
Q2
90 93 96 %
Reset threshold
headroom
V
R2HEAD
200 350 500 mV V
Q2
- V
RT2
Reset output current I
RO2
––1.6 mA V
Q2
= 5 V, V
D2
= 0 V;
V
RO2
= 0.3 V
Reset output low
voltage
V
RO2L
0.15 0.3 V V
Q2
1 V
Reset high voltage
V
RO2H
4.5 ––V R
RO2,ext
= 4.7 k
Table 4 Electrical Characteristics (contd)
V
I1
= 13.5 V; V
INH1
= V
INH2
= 5 V; -40 °C < T
j
< 150 °C; unless otherwise specified
Parameter Symbol Limit Values Unit Test Condition
Min. Typ. Max.
TLE 4473 GV55
Data Sheet 11 Rev. 1.2, 2004-01-01
Main (Tracked) Regulator
Output Q1
Output voltage
V
Q1
4.875 5.0 5.125 V 1 mA < I
Q1
< 200 mA;
6 V <
V
I
< 28 V
Output voltage
tracking accuracy
V
Q
=
V
Q2
- V
Q1
-25 5 25 mV 1 mA < I
Q1
< 200 mA;
6 V <
V
I
< 28 V
Output voltage
tracking accuracy
V
Q
=
V
Q2
- V
Q1
-25 5 25 mV 1 mA < I
Q1
< 300 mA;
8 V <
V
I
< 28 V
Output current
limitation
I
Q1
350 500 mA V
Q1
= 4.5 V
Output drop voltage
V
DRQ1
= V
I
- V
Q1
V
DRQ1
300 600 mV I
Q1
= 200 mA
1)
Load regulation V
Q1,Lo
550mV5 mA < I
Q1
< 300 mA
Line regulation
V
Q1,Li
525mVI
Q1
= 5 mA;
6 V <
V
I
< 28 V
Power Supply Ripple
Rejection
PSRR 65 dB f
r
= 100 Hz;
V
r
= 1 Vpp
Current Consumption
Quiescent current;
I
q
= I
I
- I
Q1
- I
Q2
I
q
10 20 mA I
Q1
= 300 mA;
I
Q2
= 500 µA;
V
Q1
and V
Q2
on
Quiescent current;
I
q
= I
I
- I
Q1
- I
Q2
I
q
250 500 µA I
Q2
= I
Q1
= 500 µA;
V
Q1
and V
Q2
on
Inhibit Input INH1
Turn-on Voltage V
INH1 ON
––2.3 V V
Q1
on
Turn-off Voltage
V
INH1 OFF
0.7 ––V V
Q1
off
H-input current
I
INH1 ON
-1 3.5 5 µA 3.0 V < V
INH1
< 5 V;
(see Page 14)
L-input current
I
INH1 OFF
-1 0.1 1 µA0 V < V
INH1
< 0.8 V
Table 4 Electrical Characteristics (contd)
V
I1
= 13.5 V; V
INH1
= V
INH2
= 5 V; -40 °C < T
j
< 150 °C; unless otherwise specified
Parameter Symbol Limit Values Unit Test Condition
Min. Typ. Max.
Data Sheet 12 Rev. 1.2, 2004-01-01
TLE 4473 GV55
Reset Timing D1
Charge current
I
DC1
4.0 8.0 12.0 µA V
D1
= 1 V
Upper timing
threshold
V
DU1
1.61.82.2V
Lower timing
threshold
V
DL2
0.30.40.6V
Saturation Voltage
V
D1,SAT
––100 mV V
Q1
< V
RT1
Reset delay time T
RD1
14 20 30 ms C
D1
= 100 nF
Reset reaction time
T
rr
––10 µs C
D1
= 100 nF
Reset Output RO1
Reset switching
threshold
V
RT1
4.5 4.65 4.8 V
V
RT1
/V
Q1
90 93 96 %
Reset threshold
headroom
V
R1HEAD
200 350 500 mV V
Q1
- V
RT1
Reset output current I
RO1
––1.6 mA V
Q1
= 5.0 V; V
Q2
= 5.0 V;
V
D1
= 0 V; V
RO1
= 0.3 V
Reset output low
voltage
V
RO1L
0.15 0.3 V V
Q1
1 V
Reset output high
voltage
V
RO1H
4.5 ––V R
RO1,ext
= 4.7 k
1) Drop voltage = V
I
- V
Q
(measured when the output voltage has dropped 100 mV from the nominal value
obtained at 13.5 V input)
Table 4 Electrical Characteristics (contd)
V
I1
= 13.5 V; V
INH1
= V
INH2
= 5 V; -40 °C < T
j
< 150 °C; unless otherwise specified
Parameter Symbol Limit Values Unit Test Condition
Min. Typ. Max.

TLE4473GV55AUMA1

Mfr. #:
Manufacturer:
Infineon Technologies
Description:
LDO Voltage Regulators LINEAR VOLTAGE REGULATOR
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet