74HC_HCT4051_Q100 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet Rev. 2 — 8 October 2012 18 of 31
NXP Semiconductors
74HC4051-Q100; 74HCT4051-Q100
8-channel analog multiplexer/demultiplexer
t
off
turn-off time E to V
os
; R
L
=1 k; see Figure 14
[3]
V
CC
= 4.5 V; V
EE
= 0 V - 19 45 ns
V
CC
= 5.0 V; V
EE
=0 V; C
L
= 15 pF - 16 - ns
V
CC
= 4.5 V; V
EE
= 4.5 V - 16 32 ns
Sn to V
os
; R
L
=1 k; see Figure 14
[3]
V
CC
= 4.5 V; V
EE
= 0 V - 23 45 ns
V
CC
= 5.0 V; V
EE
=0 V; C
L
= 15 pF - 20 - ns
V
CC
= 4.5 V; V
EE
= 4.5 V - 16 32 ns
C
PD
power dissipation
capacitance
per switch; V
I
= GND to V
CC
1.5 V
[4]
-25- pF
T
amb
= 40 Cto+85C
t
pd
propagation delay V
is
to V
os
; R
L
= ; see Figure 13
[1]
V
CC
= 4.5 V; V
EE
=0 V --15ns
V
CC
= 4.5 V; V
EE
= 4.5 V - - 10 ns
t
on
turn-on time E to V
os
; R
L
=1 k; see Figure 14
[2]
V
CC
= 4.5 V; V
EE
=0 V --69ns
V
CC
= 4.5 V; V
EE
= 4.5 V - - 49 ns
Sn to V
os
; R
L
=1 k; see Figure 14
[2]
V
CC
= 4.5 V; V
EE
=0 V --69ns
V
CC
= 4.5 V; V
EE
= 4.5 V - - 49 ns
t
off
turn-off time E to V
os
; R
L
=1 k; see Figure 14
[3]
V
CC
= 4.5 V; V
EE
=0 V --56ns
V
CC
= 4.5 V; V
EE
= 4.5 V - - 40 ns
Sn to V
os
; R
L
=1 k; see Figure 14
[3]
V
CC
= 4.5 V; V
EE
=0 V --56ns
V
CC
= 4.5 V; V
EE
= 4.5 V - - 40 ns
T
amb
= 40 C to +125 C
t
pd
propagation delay V
is
to V
os
; R
L
= ; see Figure 13
[1]
V
CC
= 4.5 V; V
EE
=0 V --18ns
V
CC
= 4.5 V; V
EE
= 4.5 V - - 12 ns
t
on
turn-on time E to V
os
; R
L
=1 k; see Figure 14
[2]
V
CC
= 4.5 V; V
EE
=0 V --83ns
V
CC
= 4.5 V; V
EE
= 4.5 V - - 59 ns
Sn to V
os
; R
L
=1 k; see Figure 14
[2]
V
CC
= 4.5 V; V
EE
=0 V --83ns
V
CC
= 4.5 V; V
EE
= 4.5 V - - 59 ns
Table 10. Dynamic characteristics for 74HCT4051-Q100
…continued
GND = 0 V; t
r
=t
f
=6ns; C
L
= 50 pF; for test circuit see Figure 15.
V
is
is the input voltage at a Yn or Z terminal, whichever is assigned as an input.
V
os
is the output voltage at a Yn or Z terminal, whichever is assigned as an output.
Symbol Parameter Conditions Min Typ Max Unit
74HC_HCT4051_Q100 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet Rev. 2 — 8 October 2012 19 of 31
NXP Semiconductors
74HC4051-Q100; 74HCT4051-Q100
8-channel analog multiplexer/demultiplexer
[1] t
pd
is the same as t
PHL
and t
PLH
.
[2] t
on
is the same as t
PZH and
t
PZL
.
[3] t
off
is the same as t
PHZ
and t
PLZ
.
[4] C
PD
is used to determine the dynamic power dissipation (P
D
in W).
P
D
= C
PD
V
CC
2
f
i
N + {(C
L
+C
sw
) V
CC
2
f
o
} where:
f
i
= input frequency in MHz;
f
o
= output frequency in MHz;
N = number of inputs switching;
{(C
L
+C
sw
) V
CC
2
f
o
} = sum of outputs;
C
L
= output load capacitance in pF;
C
sw
= switch capacitance in pF;
V
CC
= supply voltage in V.
t
off
turn-off time E to V
os
; R
L
=1 k; see Figure 14
[3]
V
CC
= 4.5 V; V
EE
=0 V --68ns
V
CC
= 4.5 V; V
EE
= 4.5 V - - 48 ns
Sn to V
os
; R
L
=1 k; see Figure 14
[3]
V
CC
= 4.5 V; V
EE
=0 V --68ns
V
CC
= 4.5 V; V
EE
= 4.5 V - - 48 ns
Table 10. Dynamic characteristics for 74HCT4051-Q100
…continued
GND = 0 V; t
r
=t
f
=6ns; C
L
= 50 pF; for test circuit see Figure 15.
V
is
is the input voltage at a Yn or Z terminal, whichever is assigned as an input.
V
os
is the output voltage at a Yn or Z terminal, whichever is assigned as an output.
Symbol Parameter Conditions Min Typ Max Unit
Fig 13. Input (V
is
) to output (V
os
) propagation delays
001aad555
t
PLH
t
PHL
50 %
50 %
V
is
input
V
os
output
74HC_HCT4051_Q100 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet Rev. 2 — 8 October 2012 20 of 31
NXP Semiconductors
74HC4051-Q100; 74HCT4051-Q100
8-channel analog multiplexer/demultiplexer
For 74HC4051-Q100: V
M
=0.5 V
CC
.
For 74HCT4051-Q100: V
M
=1.3V.
Fig 14. Turn-on and turn-off times
001aad556
t
PLZ
t
PHZ
switch OFF
switch ON
switch ON
V
os
output
V
os
output
E, Sn inputs
V
M
V
I
0 V
90 %
10 %
t
PZL
t
PZH
50 %
50 %
Definitions for test circuit; see Table 11:
R
T
= termination resistance should be equal to the output impedance Z
o
of the pulse generator.
C
L
= load capacitance including jig and probe capacitance.
R
L
= load resistance.
S1 = Test selection switch.
Fig 15. Test circuit for measuring AC performance
V
M
V
M
t
W
t
W
10 %
90 %
0 V
V
I
V
I
negative
pulse
positive
pulse
0 V
V
M
V
M
90 %
10 %
t
f
t
r
t
r
t
f
001aae382
V
CC
V
CC
open
GND
V
EE
V
I
V
os
DUT
C
L
R
T
R
L
S1
PULSE
GENERATOR
V
is

74HCT4051D-Q100,11

Mfr. #:
Manufacturer:
Nexperia
Description:
Multiplexer Switch ICs 74HCT4051D-Q100/SO16/REEL 13
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS