product specification 9283118301
page 4 of 7
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).
In the intake and outlet area should not be any solid obstruction within 0,5 m.
p = 0: corresp. to free air flow (see section 3.4)
I: corresp. to RMS line current
Features
Condition
Symbol
Values
Frequency p = 0 f 50 Hz 60 Hz
Nominal voltage
p = 0 U
N
230,0 V 230,0 V
Tolerance + 6,0 % - 10,0 % + 6,0 % - 10,0 %
Power consumption
p = 0 P
18,0 W 17,0 W
Tolerance
+ 5,0 % - 10,0 % + 5,0 % - 10,0 %
Current consumption
p = 0 I
105 mA *) 95 mA *)
Tolerance
+ 5,0 % - 10,0 % + 5,0 % - 10,0 %
Speed
p = 0 n
2.750 1/min *) 3.100 1/min *)
Tolerance
+- 5,0 % +- 5,0 %
*) Attention: Marked values are "FK" features
3.2 Operating Data - Electrical Interface -Output
Tacho type None
product specification 9283118301
page 5 of 7
3.3 Electrical Features
Locked rotor protection Impedance
A
Locked rotor current at Un
3.4 Aerodynamic
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m.
a.) Operation condition:
2.750 1/min at free air flow Frequency: 50 Hz
Max. free-air flow (p = 0 /
= max.) 178,0 m3/h
FK
Max. static pressure (p = max. /
=0) 80 Pa
FK
b.) Operation condition:
3.100 1/min at free air flow Frequency: 60 Hz
Max. free-air flow (p = 0 /
= max.) 200,0 m3/h
FK
Max. static pressure (p = max. /
=0) 65 Pa
FK
product specification 9283118301
page 6 of 7
3.5 Sound Data
Measurement
conditions:
Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.4
a.) Operation condition:
2.750 1/min at free air flow Frequency: 50 Hz
Optimal operating point 150,0 m3/h @ 21 Pa
Sound power level at the optimal operating
point
5,4 bel(A)
Sound pressure level at free air flow,
measured in rubber bands
42,0 dB(A)
b.) Operation condition:
3.100 1/min at free air flow Frequency: 60 Hz
Optimal operating point 162,0 m3/h @ 25 Pa
Sound power level at the optimal operating
point
5,7 bel(A)
Sound pressure level at free air flow,
measured in rubber bands
46,0 dB(A)
4 Environment
4.1 General
Min. permitted ambient temperature TU min.
-30 °C / 50 Hz
-30 °C / 60 Hz
Max. permitted ambient temperature TU max.
60 °C / 50 Hz
75 °C / 60 Hz
Min. permitted storage temperature TL min. -40 °C
Max. permitted storage temperature TL max. 80 °C
4.2 Climatic requirements*)
Humidity requirements humid heat, constant; according to DIN EN 60068-2-
78, 14 days
Water exposure None
Radiation exposure None
Dust requirements None
Salt fog requirements None
Harmful gas requirements None
*) Permittet application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly
exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.

5958W

Mfr. #:
Manufacturer:
ebm-papst
Description:
AC Fans AC Tubeaxial Fan, 127x38mm, 230VAC, 106CFM, 18W, Leadwires