product specification 9283118301
page 7 of 7
4.3 Mechanical requirements
Please require severity levels and specification parameters from the responsible development departmentsEMC
not specified
5 Safety
5.1 Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE
0700)
A.) Type test
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C.
No arcing or breakdown is allowed!
All connections together to ground.
1500 VAC / 1 Min.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
1500 VAC / 1 Sec.
A
Isolation resistance
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C measured with U=500 VDC for 1 min.
RI > 50 MOhm
Air and leakage distances 2,0 mm / 1,8 mm
Protection class I
5.2 Approval Tests
CE Yes
UL Yes / UL507, Electric Fans
VDE
Yes / Approval acc. to EN 60335 (VDE 0700) - Safety for
household and similar electrical appliances
CSA Yes / C22.2 No. 113-M1984 Fans and Ventilators
CCC Yes / GB 12350 Safety Requirements for small Power Motors
The approval tests are observed to:
U approval max.: 230 V / f: 60 Hz @ TU approval max.: 75 °C
6 Reliability
6.1 General
Life expectancy L10 at TU = 40 °C
40.000 h / 50 Hz
42.500 h / 60 Hz
Life expectancy L10 at TU max.
25.000 h / 50 Hz
20.000 h / 60 Hz
Life expectancy L10 acc. to IPC 9591 at TU = 40 °C
/ 50 Hz
/ 60 Hz