CAT810LSDI-T3

CAT803, CAT809, CAT810
http://onsemi.com
4
Table 4. ELECTRICAL CHARACTERISTICS
(V
CC
= Full range, T
A
= 40°C to +85°C, unless otherwise specified. Typical values at T
A
= +25°C and V
CC
= 5 V for the L/H/M/J
versions, V
CC
= 3.3 V for the T/S versions, V
CC
= 3 V for the R version and V
CC
= 2.5 V for the Z/V versions.)
Symbol Parameter Conditions Min
Typ
(Note 1)
Max Units
V
CC
Range
T
A
= 0°C to +70°C 1.0 5.5
V
T
A
= 40°C to +85°C 1.2 5.5
I
CC
Supply Current T
A
= 40°C
to +85°C
V
CC
< 5.5 V, J/L/M/H 8 20 mA
V
CC
< 3.6 V, R/S/T/Z/V 6 15
V
TH
Reset Threshold Voltage L Threshold
T
A
= +25°C 4.56 4.63 4.70
V
T
A
= 40°C to +85°C 4.50 4.75
H Threshold
T
A
= +25°C 4.48 4.55 4.62
T
A
= 40°C to +85°C 4.43 4.67
M Threshold
T
A
= +25°C 4.31 4.38 4.45
T
A
= 40°C to +85°C 4.25 4.50
J Threshold
T
A
= +25°C 3.93 4.00 4.06
T
A
= 40°C to +85°C 3.89 4.10
T Threshold
T
A
= +25°C 3.04 3.08 3.11
T
A
= 40°C to +85°C 3.00 3.15
S Threshold
T
A
= +25°C 2.89 2.93 2.96
T
A
= 40°C to +85°C 2.85 3.00
R Threshold
T
A
= +25°C 2.59 2.63 2.66
T
A
= 40°C to +85°C 2.55 2.70
Z Threshold
T
A
= +25°C 2.28 2.32 2.35
T
A
= 40°C to +85°C 2.25 2.38
V Threshold
T
A
= +25°C 1.58 1.60 1.62
T
A
= 40°C to +85°C 1.56 1.64
Reset Threshold Tempco 30 ppm/°C
T
D
V
CC
to Reset Delay (Note 2) V
CC
= V
TH
to (V
TH
100 mV) 20
ms
T
R
Reset Active Timeout Period T
A
= 40°C to +85°C 140 240 460 ms
V
OL
RESET Output Voltage Low
(Opendrain active LOW,
CAT803 and pushpull,
active LOW, CAT809)
V
CC
= V
TH
min, I
SINK
= 1.2 mA
CAT803R/S/T/Z, CAT809R/S/T/Z/V
0.3
V
V
CC
= V
TH
min, I
SINK
= 3.2 mA
CAT803J/L/M, CAT809J/L/M/H
0.4
V
CC
> 1.0 V, I
SINK
= 50 mA
0.3
V
OH
RESET Output Voltage High
(Pushpull, active LOW,
CAT809)
V
CC
= V
TH
max, I
SOURCE
= 500 mA
CAT809R/S/T/Z/V
0.8 V
CC
V
V
CC
= V
TH
max, I
SOURCE
= 800 mA
CAT809J/L/M/H
V
CC
1.5
V
OL
RESET Output Voltage Low
(Pushpull, active HIGH,
CAT810)
V
CC
> V
TH
max, I
SINK
= 1.2 mA
CAT810R/S/T/Z
0.3
V
V
CC
> V
TH
max, I
SINK
= 3.2 mA
CAT810J/L/M
0.4
V
OH
RESET Output Voltage High
(Pushpull, active HIGH,
CAT810)
1.8 V < V
CC
V
TH
min,
I
SOURCE
= 150 mA
0.8 V
CC
V
1. Production testing done at T
A
= +25°C; limits over temperature guaranteed by design only.
2. RESET output for the CAT809; RESET output for the CAT810.
CAT803, CAT809, CAT810
http://onsemi.com
5
TYPICAL OPERATING CHARACTERISTICS
(V
CC
= Full range, T
A
= 40°C to +85°C, unless otherwise specified. Typical values at T
A
= +25°C and V
CC
= 5 V for the
L/M/J versions, V
CC
= 3.3 V for the T/S versions, V
CC
= 3 V for the R version and V
CC
= 2.5 V for the Z version.)
Figure 2. Powerup Reset Timeout vs.
Temperature
Figure 3. Supply Current vs. Temperature
(No Load, CAT8xxR/S/T/Z)
TEMPERATURE (°C) TEMPERATURE (°C)
15010050050
160
180
200
220
240
260
10050050
0
4
6
8
10
12
Figure 4. Powerdown Reset Delay vs.
Temperature (CAT8xxR/S/T/Z)
Figure 5. Normalized Reset Threshold vs.
Temperature
TEMPERATURE (°C) TEMPERATURE (°C)
15010050050
0
4
10
14
120100806040200
0.9988
0.9990
0.9992
0.9998
1.0000
1.0002
POWERUP RESET TIMEOUT (mS)
SUPPLY CURRENT (mA)
POWERDOWN RESET DELAY (mS)
NORMALIZED THRESHOLD
150
0.9994
2
2
6
8
12
0.9996
V
CC
= 3.6 V
V
CC
= 5.5 V
V
CC
= 2.5 V
V
CC
= 5 V
CAT803, CAT809, CAT810
http://onsemi.com
6
Detailed Descriptions
Reset Timing
The reset signal is asserted LOW for the CAT803/CAT809 and HIGH for the CAT810 when the power supply voltage falls below
the threshold trip voltage and remains asserted for at least 140 ms after the power supply voltage has risen above the threshold.
0 V
CAT803, CAT809
5 V
0 V
5 V
RESET
(140 ms
minimum)
Reset Timeout Period
CAT810
0 V
5 V
Figure 6. Reset Timing Diagram
T
R
T
D
V
TH
V
CC
RESET
V
CC
Transient Response
The CAT803/CAT809/CAT810 protect mPs against
brownout failure. Short duration transients of 4 msec or less
and 100 mV amplitude typically do not cause a false RESET.
Figure 7 shows the maximum pulse duration of negative
going V
CC
transients that do not cause a reset condition.
As the amplitude of the transient goes further below the
threshold (increasing V
TH
V
CC
), the maximum pulse
duration decreases. In this test, the V
CC
starts from an initial
voltage of 0.5 V above the threshold and drops below it by
the amplitude of the overdrive voltage (V
TH
V
CC
).
Figure 7. Maximum Transient Duration without
Causing a Reset Pulse vs. Reset Comparator
Overdrive
RESET OVERDRIVE V
TH
V
CC
(mV)
1000100101
0
5
10
15
20
25
30
TRANSIENT DURATION (ms)
CAT809M
CAT809Z
T
AMB
= 25°C

CAT810LSDI-T3

Mfr. #:
Manufacturer:
ON Semiconductor
Description:
Supervisory Circuits 4.63V Push-Pull High
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union