Characteristics STTH1R06
2/9 Doc ID 10203 Rev 5
1 Characteristics
To evaluate the conduction losses use the following equation: P = 1.03 x I
F(AV)
+ 0.27 I
F
2
(RMS)
Table 2. Absolute ratings (limiting values)
Symbol Parameter Value Unit
V
RRM
Repetitive peak reverse voltage 600 V
I
F(RMS)
Forward rms current
DO-41 10
A
SMA / SMB 7
I
F(AV)
Average forward current
DO-41 T
c
= 100 °C δ = 0.5
1ASMA T
c
= 125 °C δ = 0.5
SMB T
c
= 135 °C δ = 0.5
I
FSM
Surge non repetitive forward current
DO-41
t
p
= 10ms sinusoidal
25
A
SMA / SMB 20
T
stg
Storage temperature range -65 to + 175 °C
T
j
Maximum operating junction temperature 175 °C
Table 3. Thermal resistance
Symbol Parameter Value (max) Unit
R
th(j-l)
Junction to lead
L = 10 mm DO-41 45
°C/WSMA 30
SMB 25
R
th(j-a)
Junction to ambient
(1)
L = 10 mm DO-41 70 °C/W
1. R
th(j-a)
is measured with a copper area S = Scm2 (see Figure 14).
Table 4. Static electrical characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
R
Reverse leakage current
T
j
= 25 °C
V
R
= V
RRM
1
µA
T
j
= 150 °C 10 75
V
F
Forward voltage drop
T
j
= 25 °C
I
F
= 1A
1.7
V
T
j
= 150 °C 1.0 1.25