3
Recommended Pb-Free IR Pro le
Recommended re ow condition as per JEDEC Standard, J-STD-020 (latest revision).
Note: Non-halide ux should be used
Regulatory Information
The ACPL-M46T is approved by the following organizations:
UL
Approved under UL 1577, component recognition pro-
gram up to V
ISO
= 4000 V
RMS
CSA
Approved under CSA Component Acceptance Notice
#5.
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:2007
EN 60747-5-2:2001 + A1
DIN EN 60747-5-2 (VDE 0884 Teil 2)
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
Description Symbol Characteristic Unit
Installation classi cation per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V
rms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 V
rms
I – IV
I – III
I – II
Climatic Classi cation 55/125/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
567 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875=V
PR
, 100% Production Test with t
m
=1 sec, Partial discharge < 5 pC
V
PR
1063 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6=V
PR
, Type and Sample Test, t
m
=10 sec, Partial discharge < 5 pC
V
PR
907 V
peak
Highest Allowable Overvoltage (Transient Overvoltage t
ini
= 60 sec) V
IOTM
6000 V
peak
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current
Output Power
T
S
I
S, INPUT
P
S, OUTPUT
175
230
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>109 W
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/
EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test pro les.