VN750PS-E Electrical specifications
Doc ID 16782 Rev 3 9/27
I
IH
High level input current V
IN
=3.25V 10 µA
V
hyst
Input hysteresis voltage 0.5 V
V
ICL
Input clamp voltage
I
IN
=1mA 6 6.8 8 V
I
IN
=-1mA -0.7 V
V
CC
output diode
V
F
Forward on voltage -I
OUT
= 1.3 A; T
j
= 150 °C 0.6 V
Status pin
V
STAT
Status low output voltage I
STAT
=1.6mA 0.5 V
I
LSTAT
Status leakage current Normal operation; V
STAT
=5V 10 µA
C
STAT
Status pin input capacitance Normal operation; V
STAT
= 5 V 100 pF
V
SCL
Status clamp voltage
I
STAT
=1mA 6 6.8 8 V
I
STAT
=-1mA -0.7 V
Protections
(1)
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature 135 °C
T
hyst
Thermal hysteresis 7 15 °C
t
SDL
Status delay in overload
condition
T
j
>T
jsh
20 ms
I
lim
Current limitation
9V<V
CC
<36 V 6 9 15 A
5V<V
CC
<36 V 15 A
V
demag
Turn-off output clamp
voltage
I
OUT
= 2 A; V
IN
=0V;
L=6mH
V
CC
-41 V
CC
-48 V
CC
-55 V
Open-load detection
I
OL
Open-load on-state
detection threshold
V
IN
= 5 V 50 200 mA
t
DOL(on)
Open-load on-state
detection delay
I
OUT
= 0 A 200 µs
V
OL
Open-load off-state voltage
detection threshold
V
IN
=0V 1.5 3.5 V
t
DOL(off)
Open-load detection delay at
turn-off
1000 µs
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related diagnostic signals
must be used together with a proper software strategy. If the device operates under abnormal conditions this software must
limit the duration and number of activation cycles.
Table 5. Electrical characteristics (continued)
Symbol Parameter Test conditions Min. Typ. Max. Unit