MAX13020/MAX13021
±60V Fault-Protected LIN Transceivers
4
Maxim Integrated
ELECTRICAL CHARACTERISTICS (continued)
(V
BAT
= +5V to +38V, T
A
= -40°C to +125°C, unless otherwise noted. Typical values are at V
BAT
= +12V and T
A
= +25°C. Positive
currents flow into the device.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
High-Level Leakage Current I
LH
V
LIN
= V
BAT
, V
TXD
= +5V -5 0 +5 µA
Device Leakage Current, V
BAT
Disconnected
I
L(BAT)
V
BAT
= V
GND
, V
LIN
= +18V -5 0 +5 µA
Device Leakage Current, GND
Disconnected
I
L(GND)
V
BAT
= V
GND
, V
LIN
= -18V -100 0 µA
LIN Current After Short Detection I
IL(FAULT)
Fault mode, disable mode (MAX13021)
V
LIN
= V
GND
-10 -2 µA
Short-Circuit Recovery Threshold
Voltage
V
th
RECOVERY
Fault mode, disable mode (MAX13021)
V
BAT
-
2.5
V
BAT
-
0.9
V
LIN Pullup Current I
IL
Sleep mode, V
LIN
= V
GND
, V
NSLP
= V
GND
-10 -2 µA
Slave Termination Resistance to
V
BAT
R
SLAVE
S tand b y, nor m al /l ow sl op e m od es, V
LIN
=
V
GND
, V
BAT
= + 12V
20 30 47 kΩ
V
LIN
= V
BAT
= +12V,
V
TXD
= V
GND
, t < t
DOM
27 40 60
V
LIN
= +12V, V
BAT
= +27V,
V
TXD
= V
GND
, t < t
DOM
(Note 1)
45 70 100
Short-Circuit Output Current I
O(SC)
V
BAT
= +12V, V
LIN
= +60V, V
TXD
= V
GND
,
t < t
DOM
45
mA
Receiver Dominant State V
th(DOM)
V
BAT
= +7V to +38V 0.4 x V
BAT
V
Receiver Recessive State V
th(REC)
V
BAT
= +7V to +38V 0.6 x V
BAT
V
Receiver-Threshold Center
Voltage
V
th
CENTER
V
BAT
= +7V to +38V
0.475 x
V
BAT
0.5 x
V
BAT
0.525 x
V
BAT
V
Receiver-Threshold Hysteresis
Voltage
V
th(HYS)
V
BAT
= +7V to +38V
0.145 x
V
BAT
0.16 x
V
BAT
0.175 x
V
BAT
V
Thermal-Shutdown Threshold T
SHDN
+165 °C
Thermal-Shutdown Hysteresis 10 °C
ESD PROTECTION
Human Body Model LIN ±12 kV
Contact Discharge
IEC61000-4-2
LIN, NWAKE, BAT
(tested to IBEE test setup)
C
1
= 100nF on V
BAT
,
C
2
= 220pF on LIN,
R = 33kΩ on NWAKE
±4 kV