0
15
10
5
20
25
30
35
40
45
50
021345
SINK CURRENT vs. TXD PULLDOWN
OUTPUT VOLTAGE
MAX13020 toc04
OUTPUT LOW VOLTAGE (V)
SINK CURRENT (mA)
T
A
= +125°C
T
A
= +25°C
T
A
= -40°C
STANDBY MODE
AFTER A LOCAL
0
10
5
25
20
15
30
35
45
40
50
-40 -10 5-25 203550658095110125
INH ON-RESISTANCE
vs. TEMPERATURE
MAX13020 toc05
TEMPERATURE (
°
C)
INH ON-RESISTANCE ()
I
SINK
= 15mA
V
BAT
= +38V
V
BAT
= +12V
0
20
10
50
40
30
60
70
90
80
100
-40 -10 5-25 203550658095110125
I
BAT
FAULT CURRENT
vs. TEMPERATURE
MAX13020 toc06
TEMPERATURE (
°
C)
I
BAT
FAULT CURRENT (µA)
MAX13020
V
BAT
= +12V
SLEEP MODE
V
LIN
= 0V
20µs/div
2.5MHz/div
LIN OUTPUT SPECTRUM
LIN
5V/div
FFT
20dB/div
MAX13020 toc08
R
L
= 660
C
L
= 6.8nF
LOW SCOPE MODE
10.4kbps
MAX13020/MAX13021
±60V Fault-Protected LIN Transceivers
7
Maxim Integrated
20µs/div
LIN TRANSMITTING NORMAL
SLOPE MODE
TX
5V/div
RX
5V/div
MAX13020 toc09
R
L
= 1k
C
L
= 1nF
NORMAL SCOPE MODE
20kbps
LIN
5V/div
Typical Operating Characteristics (continued)
(V
BAT
= +12V and T
A
= +25°C, unless otherwise noted.)
MAX13020/MAX13021
±60V Fault-Protected LIN Transceivers
8
Maxim Integrated
Typical Operating Characteristics (continued)
(V
BAT
= +12V and T
A
= +25°C, unless otherwise noted.)
10µs/div
LIN TRANSMITTING NORMAL
SLOPE MODE
TX
5V/div
RX
5V/div
MAX13020 toc10
R
L
= 660k
C
L
= 6.8nF
NORMAL SCOPE MODE
20kbps
LIN
5V/div
10µs/div
TX
5V/div
RX
5V/div
MAX13020 toc11
R
L
= 500k
C
L
= 10nF
NORMAL SCOPE MODE
20kbps
LIN
5V/div
LIN TRANSMITTING NORMAL
SLOPE MODE
20µs/div
TX
5V/div
RX
5V/div
MAX13020 toc12
R
L
= 1k
C
L
= 1nF
LOW SCOPE MODE
10.4kbps
LIN
5V/div
LIN TRANSMITTING LOW
SLOPE MODE
20µs/div
TX
5V/div
RX
5V/div
MAX13020 toc13
R
L
= 660k
C
L
= 6.8nF
LOW SCOPE MODE
10.4kbps
LIN
5V/div
LIN TRANSMITTING LOW
SLOPE MODE
20µs/div
TX
5V/div
RX
5V/div
MAX13020 toc14
R
L
= 500k
C
L
= 10nF
LOW SCOPE MODE
10.4kbps
LIN
5V/div
LIN TRANSMITTING LOW
SLOPE MODE
Detailed Description
The MAX13020/MAX13021 ±60V fault-protected low-
power local interconnect network (LIN) transceivers are
ideal for use in automotive network applications where
high reliability is required. The devices provide the
interface between the LIN master/slave protocol con-
troller and the physical bus described in the LIN 2.0
specification package and SAE J2602 specification.
The devices are intended for in-vehicle subnetworks
with a single master and multiple slaves.
The extended fault-protected voltage range of ±60V on
the LIN bus line allows for use in +12V, +24V, and
+42V automotive applications. The devices allow com-
munication up to 20kbaud, and include slew-rate limit-
ed transmitters for enhanced electromagnetic
emissions (EME) performance. The devices feature a
low-power 4µA sleep mode and provide wake-up
source detection.
The MAX13020 is a pin-to-pin replacement and is func-
tionally compatible with the Philips TJA1020. The
MAX13021 includes enhanced bus dominant clamping
fault-management for reduced quiescent current during
LIN bus shorts to GND.
Operating Modes
The MAX13020/MAX13021 provide two different trans-
mitting modes, an intermediate standby mode and a
low-power sleep mode. Normal slope mode allows full-
speed communication at 20kbaud with a slew-limited
transmitter to reduce EME. Low slope mode permits
communication up to 10.4kbaud, and provides addi-
tional slew-rate limiting to further reduce EME. The
transmitting operating mode is selected by the logic
state of NSLP and TXD (Table 1). To enter normal slope
mode or low slope mode, drive TXD logic-high or logic-
low, then drive NSLP logic-high for longer than
t
GOTONORM
. The MAX13021 features two additional
operating modes to reduce current consumption during
LIN bus shorts to GND.
On initial power-up, the device enters sleep mode.
MAX13020/MAX13021
±60V Fault-Protected LIN Transceivers
9
Maxim Integrated
Pin Description
PIN NAME FUNCTION
1 RXD
Data Receive Output, Open Drain. RXD is logic-low when the LIN bus is dominant. RXD is active low after
a wake-up event from sleep mode.
2 NSLP S l eep Inp ut. D r i ve N S LP l og i c- hi g h or l og i c- l ow to contr ol the op er ati ng m od e. ( S ee Tab l e 1 and Fi g ur es 1, 2)
3 NWAKE
Local Wake-Up Input. Present a falling edge on NWAKE to generate a local wake-up event. Connect
NWAKE to BAT with a 5k resistor if local wake-up is not required.
4 TXD
Data Transmit Input, CMOS Compatible. Drive TXD logic-low to force the LIN bus to a dominant state in
normal/low slope mode.
5 GND Ground
6 LIN
LIN Bus I/O. LIN is terminated with an internal 30k resistor in normal slope, low slope, and standby
modes.
7 BAT
Battery Voltage Input. Bypass BAT to ground with a 0.1µF ceramic capacitor as close to the device as
possible.
8 INH Inhibit Output. INH is active high in standby and normal/low slope modes. (See Table 1)
NORMAL SLOPE MODE
STANDBY MODE
LOW SLOPE MODE
SLEEP MODE
t
(NSLP = 1 AFTER 0 TO 1)
> t
GOTONORM
TXD = 1
t
(NSLP = 1 AFTER 0 TO 1)
> t
GOTONORM
TXD = 1
t
(NSLP = 1 AFTER 0 TO 1)
> t
GOTONORM
TXD = 0
(t
NWAKE
= 0 AFTER 1 TO 0) > t
NWAKE
OR
t
(LIN = 0 AFTER 1 TO 0)
>t
BUS
t
(NSLP = 0 AFTER 1 TO 0)
> t
GOTOSLEEP
t
(NSLP = 0 AFTER 1 TO 0)
> t
GOTOSLEEP
t
(NSLP = 1 AFTER 0 TO 1)
> t
GOTONORM
TXD = 0
INITIAL
POWER-ON STATE
Figure 1. MAX13020 Operating Modes

MAX13021ASA/V+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
LIN Transceivers 60V+/- Fault Prot LIN Transceiver
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union