D1U4-W-1600-12-Hx Series
AC/DC Front End Power Supply
CPS_D1U4-W-1600-12-Hx.B02 Page 1 of 6
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
FEATURES
1600W (220Vac), 1200W (110Vac)
Output Power
12V Main Output,
3.3V or 5V Standby Output
1U height: 4.0" x 14.0" x 1.6"
17.9 Watts per cubic inch density
N+1 redundancy capable,
including hot-docking
Active Current Sharing on main output
Overvoltage, Overcurrent,
Overtemperature protection
Internal cooling fans
I²C Bus Interface with Status Indicators
Optional 1U x 19" Power-Shelf
RoHS compliant
ORDERING GUIDE
Model Number
Power Output
High Line AC
Power Output
Low Line AC
Main
Output
Standby
Output
Airflow
D1U4-W-1600-12-HC2C 1600W 1200W 12V 3.3V Back to front
D1U4-W-1600-12-HA2C 1600W 1200W 12V 5V Back to front
D1U4-W-1600-12-HC1C 1600W 1200W 12V 3.3V Front to back
D1U4-W-1600-12-HA1C 1600W 1200W 12V 5V Front to back
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Input Voltage Operating Range 90 115/230 264 Vac
Input Frequency 47 55 63 Hz
Turn-on Input Voltage Ramp up 78.5 86.5
Vac
Turn-off Input Voltage Ramp down 70.5 78
Maximum Input Current
Low Line AC 90Vac 15
Arms
High Line AC 180Vac 10
Inrush Current Cold start between 0-1msec 100 Apk
Power Factor
Output load >90% 95%
Output load >50% 75%
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage
Parameter Conditions Min. Typ. Max. Units
12V
Voltage Set Point Accuracy 12.12
Vdc
Line and Load Regulation 11.75 12.48
Ripple Voltage & Noise 20MHz Bandwidth 120 mV p-p
Output Current 0 131.6 A
Load Capacitance 40000 µF
3.3Vsb
Voltage Set Point Accuracy 3.3
Vdc
Line and Load Regulation 3.2 3.4
Ripple Voltage & Noise 20MHz Bandwidth 33 mV p-p
Operating Range 0 6 A
Load Capacitance 1530 µF
5Vsb
Voltage Set Point Accuracy 5
Vdc
Line and Load Regulation 20MHz Bandwidth 4.85 5.15
Ripple Voltage & Noise 50 mV p-p
Operating Range 0 4 A
Load Capacitance 1530 µF
1
Ripple and noise are measured with 0.1 uF of ceramic capacitance and 2 x 270 uF of OSCON capacitance on each
of the power supply outputs. A short coaxial cable with 50ohm scope termination is used. See Ripple Test Setup
diagram.
PRODUCT OVERVIEW
The D1U4-W-1600-12-Hx is a 1600 Watt, power-factor-corrected (PFC) front-end power supply for hot-swapping
redundant systems. The main output is 12V with a standby output of either 5V or 3.3V. Packaged in a 1U low-profile
enclosure, it is designed to deliver reliable bulk power to servers, workstations, storage systems or any 12V distrib-
uted power architecture systems requiring high power density. The highly efficient electrical and thermal design with
internal cooling fans supports reliable operation conditions. The D1U4-W-1600-12-Hx is designed to autorecover
from overcurrent and overtemperature faults. Status information is provided with front panel LEDs, logic signals and
I
2
C management interface. Four units can be packaged into an optional 19" 1U power shelf to provide up to 6.4kW of
power.
CB
Test Certicate
and Test Report