60W Multiple-Stage Constant Current Mode LED Driver
LCM-60DA
series
SPECIFICATION
MODEL
LCM-60DA-
DC VOLTAGE RANGE
RATED POWER
OUTPUT
SETUP TIME
Note.3
VOLTAGE RANGE Note.2
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
Note.4
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
DALI STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
60.3W
95V
73V
500ms / 230VAC
180 ~ 295VAC 254 ~ 417VDC
47 ~ 63Hz
92%
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
4. Efficiency is measured at 900mA/67V output set by DIP switch.
5. Current ripple is measured 60%~100% of maximum voltage under rated power delivery.
6. Standby power consumption is measured at 180 230VAC.
~
7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft)℃℃ .
OPEN CIRCUIT VOLTAGE (max.)
ENVIRONMENT
SAFETY &
FUNCTION
EMC
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
Comply with IEC62386-101, 102, 207
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH℃
CURRENT LEVEL
CURRENT TOLERANCE
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
TEMP. COMPENSATION
SYNCHRONIZATION
Constant current limiting, recovers automatically after fault condition is removed
Shutdown o/p voltage,re-power on to recover
Please refer to "SYNCHRONIZATION OPERATION” section
DIMMING
Please refer to "DIMMING OPERATION" section
Shutdown o/p voltage, re-power on to recover
105 ~ 125V
By external NTC, please refer to “TEMPERATURE COMPENSATION OPERATION”section
TOTAL HARMONIC DISTORTION
<0.5mA / 240VAC
PF 0.975/230VAC, PF 0.96/277VAC≧≧@
full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
COLD START 20A(t =270 s measured at 50% I ) at 230VAC
width peakμ ; Per NEMA 410
±5%
±0.03%/ (0 ~ 50 )℃℃
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
25 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
File Name:LCM-60DA-SPEC 2018-05-02
(Please refer to "STATIC CHARACTERISTIC" section)
WORKING TEMP.
MAX. CASE TEMP.
Tcase=+90℃
Tcase=-30 ~ +90 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)℃
AUXILIARY DC OUTPUT
Nominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type only
CURRENT RIPPLE
Note.5
5.0% max. @rated current
Current level selectable via DIP switch, please refer to”DIP SWITCH TABLE” section
THD< 20%(@load 75%)≧
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
Compliance to EN55015, EN61000-3-2 Class C(@load 40%) ; EN61000-3-3;≧ GB17625.1,GB17743, EAC TP TC 020
EMC IMMUNITY
193.6K hrs min. MIL-HDBK-217F (25 )℃
123.5*81.5*23mm (L*W*H)
0.24Kg ; 54pcs/15Kg/1.12CUFT
<0.5W for Blank-Type, <1.2W for AUX-Type
STANDBY POWER
CONSUMPTION
Note.6
EMC EMISSION Note.7
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level surge immunity Line-Line 2KV , EAC TP TC 020()
500mA 700mA(default)600mA 900mA 1050mA 1400mA
2 ~ 90V 2 ~ 86V2 ~ 90V 2 ~ 67V 2 ~ 57V 2 ~ 42V
0.32A/230VAC 0.27A/277VAC
UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 independent,GB19510.14,GB19510.1,
CSA C22.2 No.250.13-12,
BIS IS15885, EAC TP TC 004 approved