LCM-60DA

File Name:LCM-60DA-SPEC 2018-05-02
60W Multiple-Stage Constant Current Mode LED Driver
LCM-60DA
DA-
Push Button
AC/N
AC/L
DA+
PUSH
AC/N
AC/L
DIMMING OPERATION
PUSH dimming(primary side)
The factory default dimming level is at 100%.
If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver.
Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button.
DALI protocol comprises 16 groups and 64 addresses.
First step is fixed at 6% of output.
DALI interface(primary side)
Action FunctionAction duration
Short push 0.1~1 sec. Turn ON-OFF the driver
Long push 1.5~10 sec. Every Long Push changes the dimming direction, dimming up or down
Reset >11 sec. Set up the dimming level to 100%
The maximum length of the cable from the push button to the last driver is 20 meters.
LCM-60DA
series
The additive push button can be connected only between the PUSH terminal, as displayed in the diagram,
and AC/L (in brown or black); it will lead to short circuit if it is connected to AC/N.
Apply DALI signal between DA+ and DA-
65
70
75
80
85
90
95
100
105
55 60 65 70 75 80 85 90 95
220KO
330KO
470KO
NTC derating curve
220KΩ
330KΩ
470KΩ
Sensed Temperature( )
Output Current (%)
TEMPERATURE COMPENSATION OPERATION
LCM-60DA have the built-in temperature compensation function ; by connecting a temperature sensor (NTC resistor) between the +NTC / -NTC
terminal of LCM-60DA and the detecting point on the lighting system or the surrounding environment, output current of LCM-60DA could be
correspondingly changed, based on the sensed temperature, to ensure the long life of LED.
NTC resistance
220K
330K
470K
Output Current
< 60 , 100% of the rated current (corresponds to the setting current level)
< 70 , 100% of the rated current (corresponds to the setting current level)
< 80 , 100% of the rated current (corresponds to the setting current level)
> 60 , output current begins to reduce, please refer to the curve for details.
> 70 , output current begins to reduce, please refer to the curve for details.
> 80 , output current begins to reduce, please refer to the curve for details.
Dimming and synchronization function of the driver will be invalid when the "temperature compensation" function is in use.
Notes: 1. MEAN WELL does not offer the NTC resistor and all the data above are measured by using THINKING TTC03 series.
2. If other brands of NTC resistor is applied,please check the temperature curve first.
LCM-60DA can still be operated normally when the NTC resistor is not connected and the value of output current will be the current level selected
through the DIP switch.
File Name:LCM-60DA-SPEC 2018-05-02
NTC reference:
60W Multiple-Stage Constant Current Mode LED Driver
LCM-60DA
series
Synchronization up to 10 drivers (1 master + 9 slaves)
Dimming operating range : 10%~100%
Sync cable length : < 5m
Sync cable type : Flat cable
Sync cable cross section area : 22 – 24 AWG (0.2~0.3mm )
2
LCM-60DA
(Slave 2)
------
+
+
+
+
+
+
SYN. SYN. SYN.
LCM-60DA
(Master)
LCM-60DA
(Slave 1)
SYNCHRONIZATION OPERATION
5m 5m
NOTE 1. Please make sure all units are set to 100% dimming setting (factory default) before synchronizing.:
2. Min. Dimming operating range depends on dimmer setting.
File Name:LCM-60DA-SPEC 2018-05-02
60W Multiple-Stage Constant Current Mode LED Driver
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
AMBIENT TEMPERATURE,Ta ( )
LOAD (%)
INPUT VOLTAGE (V) 60Hz
LOAD (%)
(HORIZONTAL)
Tcase ( )
LOAD (%)
(HORIZONTAL)
De-rating is needed under low input voltage.
-30-250 204555657590
20
40
60
80
100
LCM-60DA
series
Others
20
40
60
80
100
-15 0 15 3004050-30 60 70
1050mA
180 190 200 210 220 230 240 260 270 280 295
100
90
80
70
60
50
40
250

LCM-60DA

Mfr. #:
Manufacturer:
MEAN WELL
Description:
LED Power Supplies 60.3W 180-295VinDALI 500-1400mA slct curr
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union