QUINT POWER provides:
Preventive function monitoring
through
professional signaling
Global use
due to a wide range input
A high level of operational safety
even in complex
global networks
Reliable startup of heavy loads
due to POWER
BOOST
The reliability of a power supply determines the
availability of individual components in a system and
whether complex systems can function safely.
The globalization of markets increases the demands
placed on the power supply. A wide range input and a
high level of availability are required.
These requirements are met by Generation 2
QUINT POWER.
1. Brief Description
The QUINT POWER product range offers universal
DC power supplies from 60 - 960 W. Depending on the
type, regulated and adjustable output voltages of
12 V DC, 24 V DC or 48 V DC are available for output
currents of 2.5 A, 5 A, 10 A, 20 A, 30 A, and 40 A.
These devices, which are designed as primary
switched-mode regulators, operate with a high level of
efciency so that the heat loss is kept to a minimum.
The high level of operational safety is also ensured in
complex global networks. QUINT POWER also
operates in applications where static voltage dips,
transient power supply failures or phase failure are
common.
Large capacitors ensure mains buffering of more
than 20 ms at full load. All 3-phase QUINT POWER
units provide the complete output power even in the
event of a continuous phase failure.
Reliable startup of heavy loads is ensured by a
power reserve of up to 50% - the POWER BOOST.
Preventive function monitoring diagnoses an
impermissible operating state and minimizes
downtimes in your system. An active transistor output
and an electrically isolated relay contact are provided
for remote monitoring of this state.
This signal not only provides information on the
device function, but also indicates a system overload at
an early stage.
2. Area of Application
QUINT POWER can be used globally due to the
consistent provision of a wide range input.
In this way, your entire system can be tested at any
production location in the world and can be delivered to
any location in the world without faulty switching of the
input voltage. This reduces storage costs and logistical
effort.
An international approval package including CB
Scheme, UL 60950 for IT equipment, and UL 508 for
industrial control equipment enables the device to be
used globally.
Safe operation in adverse conditions is emphasized
by the approval of all QUINT POWER units with 24 V
output voltage by Germanischer Lloyd.
3-Phase Power Supply, Primary Switch Mode
for Universal Use
QUINT-PS-3x400-500AC/48DC/10
Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany
Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com
Local Contact: www.phoenixcontact.com/salesnetwork
PHOENIX CONTACT page 2 of 10
solid exible torque
[mm
2
]AWG [Nm] [Ib in.]
Input 0,2-6 0,2-4 24-10 0,5-0,6 4,4-5,3
Output 0,5-16 0,5-10 20-6 1,2-1,5 10,6-13,3
Signal 0,5-16 0,5-10 20-6 1,2-1,5 10,6-13,3
Description
Power Supply
,
Primary switch mode for universal use
Technical Data
Input Data
1
Nominal input voltage
Input voltage range
Frequency
Current consumption (for nominal values)
Inrush current limiting/I
2
t (+25°C [+77°F])
Mains buffering for a nominal load (typical)
Switch-on time after applying the mains voltage
Transient surge voltage protection
Input fuse, internal
Recommended fuse
Discharge current for PE
Output Data
2
Nominal output voltage U
N
/tolerance
Setting range for the output voltage
Output current (continuous) during convection cooling and nominal
values POWER BOOST I
BOOST
-25°C to +40°C (-13°F to +104°F)
Nominal output current I
N
-25°C to +60°C (-13°F to +140°F)
Derating
Short-circuit current limit
Startup of capacitive loads
System deviation on: Load change static 10 - 90%
Load change dynamic 10 - 90%
Input voltage change ±10%
Maximum power loss No load/nominal load
Efciency
Response time U
OUT
(10% - 90%)
Residual ripple/switching peaks (20 MHz)
Can be connected in parallel
Internal surge voltage protection
Resistance to return supply
Signal Output Data
DC OK (active)
3
(U
out
> 0.9 x U
N
=
high signal)
DC OK (electrically isolated)
4
(U
out
> 0.9 x U
N
=
contact closed)
LED
6
(U
out
< 0.9 x U
N
=
LED ashing)
QUINT 48 V DC/10 A
3 AC
U u B
Stripping Lengths
[mm]
8 mm (0.31 in.)
10 mm (0.39 in.)
10 mm (0.39 in.)
Type Order No.
Pcs
.
Pkt.
QUINT-PS-3x400-500AC/48DC/10 29 38 21 9
1
3 x 400 - 500 V AC (wide range input)
3 x 320 - 575 V AC 450 - 800 V DC
45 - 65 Hz 0 Hz
3 x 1.2 A (400 V AC)/3 x 1.0 A (480 V AC), approximately
15 A, approximately/1 A
2
s, approximately
> 20 ms (for 3 x 400 V AC)/> 30 ms (for 3 x 480 V AC)
< 1 s
Varistor
(Device protected by a circuit breaker)
3 x circuit breaker 6, 10 or 16 A
Characteristic B (EN 60 898)
< 3.5 mA
48 V DC ±1%
40 - 56 V DC
13 A (U
out
= 48 V DC)
10 A (U
out
= 48 V DC)
From +60°C (+140°F), 2.5% per Kelvin
I
BOOST
13 A, approximately
Unlimited
< 1%, typical
< 5%, typical
< 0.1%, typical
10 W/45 W, approximately
> 90% (for 400 V AC and nominal values)
< 10 ms, typical
< 200 mV
pp
(for nominal values)
To increase redundancy and power
Ye s, limited to 60 V DC, approximately
60 V DC
+24 V DC signal (with regard to the device weight)
20 mA, maximum
60 V AC/DC, maximum; 0.5 A, maximum
Green LED
CB
Schem
130 mm
(5.118 in.)
160 mm
(6.299 in.)
125 mm
(4.921 in.)
L2
PE
13
14
DC OK
L1 (+)
L3 (–)
3-Phase Power Supply, Primary Switch Mode for Universal Use – QUINT 48 V DC/10 A
3. Technical Data
PHOENIX CONTACT page 3 of 10
3-Phase Power Supply, Primary Switch Mode for Universal Use – QUINT 48 V DC/10 A
General Data
Insulation voltage: Input/output
Input/PE
Output/PE
Approval package
Electrical equipment of machines
Safety transformers for switched-mode power supply units
Electrical safety
(of IT equipment)
Industrial control equipment
Equipping high voltage installations
with electronic equipment
Safety extra-low voltage
Safe isolation
Protection against electric shock
Protection against dangerous shock currents,
basic requirements for safe isolation
in electrical equipment
Limitation of harmonic line currents
Mounting position
Degree of protection
Class of protection
MTBF
Housing version
Dimensions (W x H x D) + DIN rail
Weight
Climatic Data
Ambient temperature Operation
Storage
Humidity
Vibration according to IEC 68-2-6
Shock according to IEC 68-2-27
Degree of pollution
Climatic category
c
Conforms to the EMC Directive 89/336/EEC and the
Low Voltage Directive 73/23/EEC
EMC (Electromagnetic Compatibility)
Noise Immunity According to EN 61000-6-2:
Electrostatic discharge
(ESD)
EN 61000-4-2
3)
Housing
Contact discharge:
Air discharge:
Electromagnetic
HF eld
EN 61000-4-3
2)
Housing
Frequency:
Field strength:
Fast transients
(burst)
EN 61000-4-4
3)
Input:
Output:
Signal:
Surge current loads EN 61000-4-5
3)
Input:
Output:
Signal:
Conducted
interference
EN 61000-4-6
2)
I/O/S:
Frequency:
U
0
:
Voltage dips EN 61000-4-11
3)
Input:
Noise Emission According to EN 50081-2:
Radio interference EN 55011
Radio interference EN 55011
EN 55011 corresponds to CISPR11/EN 55022 corresponds to CISPR22
EN 61000 corresponds to IEC 1000
2)
Criterion A: Normal operating characteristics within the specied
limits.
3)
Criterion B: Temporary adverse effects on the operating
characteristics that the device corrects independently.
3 kV AC (type test)/1.5 kV AC (routine test)
1.5 kV AC (type test)/1.25 kV AC (routine test)
1.25 kV AC (type test)/1.25 kV AC (routine test)
BB
BB
EN 60 204 (Surge Voltage Category III)
EN 61 558-2-17
EN 60950/VDE 0805,
UL/C-UL Recognized UL 60 950
u
1)
UL/C-UL Listed UL 508
1)
EN 50 178 (VDE 0160)
PELV (EN 60 204)
SELV (EN 60 950)
VDE 0100-410
DIN 57100-410
DIN VDE 0106-101
According to EN 61000-3-2
On horizontal NS 35 DIN rail according to EN 50022
IP 20
Ι
, with PE connection
> 500 000 h according to IEC 1709 (SN 29 500)
AluNox (AlMg1), closed
Default upon delivery: Rotated 90°:
(160 x 130 x 125 mm [6.299 x 5.118 x 4.921 in.])(122 x 130 x 163
mm [4.803 x 5.118 x 6.417 in.])
-25°C to +70°C (-13°F to +158°F) (> +60°C [+140°F] derating)
-40°C to +85°C (-40°F to +185°F)
Up to 95% at +25°C (+77°F), no condensation
< 15 Hz, amplitude ±2.5 mm/15 Hz - 150 Hz, 2.3 g, 90 minutes
in resonant frequency
30 g all space directions
2 (according to EN 50 178)
3K3 (according to EN 60 721)
1)
UL approval for AC input voltage and ambient temperature up to
+70°C (+158°F)
Requirements
EN 61 000-6-2
QUINT-PS-3x400-500AC/48DC/
10
4 kV
8 kV
Level 4
8 kV
15 kV
80 - 1000 MHz
10 V/m
Level 3
80 - 1000 MHz
10 V/m
2 kV asymmetrical
5)
2 kV asymmetrical
5)
1 kV asymmetrical
5)
4 kV (Level 4)
2 kV (Level 3)
1 kV (Level 2)
2 kV asymmetrical
5)
1 kV symmetrical
4)
0.5 kV asymmetrical
5)
0.5 kV symmetrical
4)
1 kV asymmetrical
5)
4 kV (Level 4)
2 kV (Level 4)
0.5 kV (Level 1)
0.5 kV (Level 1)
1 kV (Level 2)
asymmetrical
5)
0.15 - 80 MHz
10 V
Level 3
0.15 - 80 MHz
10 V
30% reduction of the input
voltage for 0.5 periods
See input data:
Mains buffering
> 20 ms
Class A
6)
EN 55011 (EN 55022) Class B
7)
Class A
6)
EN 55011 (EN 55022) Class B
7)
4)
symmetrical: Cable to cable
5)
asymmetrical: Cable to ground
6)
Class A: Industrial application
7)
Class B: Industrial and domestic applications
CB
Schem
U
LISTED

2938219

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
DIN Rail Power Supplies QUINT 3PHS 48VDC 10A