Obsolete Product(s) - Obsolete Product(s)
M48T86 DC and AC parameters
25/36
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 12. AC testing load circuit (no IRQ
)
Table 10. Operating and AC measurement conditions
Parameter M48T86 Unit
Supply voltage (V
CC
) 4.5 to 5.5 V
Ambient operating temperature (T
A
) 0 to 70 °C
Load capacitance (C
L
)100pF
Input rise and fall times ≤ 5ns
Input pulse voltages 0 to 3 V
Input and output timing ref. voltages 1.5 V
AI01644
5V
50pF
960Ω
FOR ALL
OUTPUTS
EXCEPT IRQ
510Ω