TS33010
Final
Rev
June 2
,
2016
4of
Absolute Maximum
R
a
ting
Over operating free–air temperature range unless otherwise noted
(1, 2)
Parameter
Value
Unit
V
CC
-0.3
to
6.0
V
VSW
-1
to
6.0
V
EN, PG,FB, nLP, TEST
OUT, V
OUT
S
ense
-0.3
to
6.0
V
Electrostatic Discharge – Human Body
Model
±2k
V
Electrostatic Discharge – Charge Device
Model
±500
V
Lead Temperature
(solder
ing
,
10
seconds)
260
°C
Notes:
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating con-
ditions” is not implied. Exposure to
absolute–maximum–rated
conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to network ground terminal.
Thermal
C
har
ac
t
eristics
S
ymbol
P
arameter
Value
Unit
ș
JA
Thermal Resistance Junction
to
Air (Note
1)
50
°C/W
ș
JC
Thermal Resistance Junction to Case (Note 1)
3.9
°C/W
Note 1: Assumes QFN16 1 in
2
area of 2 oz copper and 25°C ambient temperature.
Recommended Operating
C
onditions
S
ymbol
P
arameter
Min Typ Max Unit
V
CC
Input
Operating
V
oltage
2.0 3.6 5.5 V
T
S
TG
S
t
or
age Temperature
R
ange
-65 150 °C
T
J
MAX
Maximum Junction
T
emper
a
tur
e
150 °C
T
J
Operating Junction Temperature
R
ange
-40 125 °C
L
OUT
Output
Filter
Inductor
Typical Value (Note
1,3)
1.5 μH
C
OUT
Output
Filter Capacitor Typical Value (Note
2,3)
3.3 10 13 μF
C
OUT
-ESR
Output
Filter Capacitor ESR
0520Pȍ
C
BY
PAS S
Input
Supply Bypass Capacitor Typical Value (Note
2)
22 μF
Note 1: For best performance, an inductor with a saturation current rating higher than the maximum V
out
load requirement plus the inductor
current ripple. See the inductor current ripple calculations in inductor calculations sections.
Note 2: For best performance, a low ESR ceramic capacitor– X7R or X5R types should be used. Y5V should be avoided.
Note 3: Min and max listed are to account for +/-20% variation of the typical value. Typical values of 10μF and 1.5μH are recommended.