1
FN6617.2
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Copyright Intersil Americas Inc. 2007, 2008, 2011. All Rights Reserved
Intersil (and design) is a trademark owned by Intersil Corporation or one of its subsidiaries.
All other trademarks mentioned are the property of their respective owners.
ISL12030
Real Time Clock with 50/60 Hz Clock and Alarms
Low Power RTC with 50/60 Cycle AC
Input, Alarms and Daylight Savings
Correction
The ISL12030 device is a low power real time clock with
50/60 AC input for timing synchronization, clock/calendar
registers, single periodic or polled alarms. There are 128
bytes of user SRAM.
The oscillator uses a 50/60 cycle sine wave input. The real
time clock tracks time with separate registers for hours,
minutes, and seconds. The calendar registers contain the
date, month, year, and day of the week. The calendar is
accurate through year 2100, with automatic leap year
correction and auto daylight savings correction.
Pinout
ISL12030
(8 LD SOIC)
TOP VIEW
Features
50/60 Cycle AC as a Primary Clock Input for RTC Timing
Real Time Clock/Calendar
- Tracks Time in Hours, Minutes, Seconds and tenths of a
Second
- Day of the Week, Day, Month and Year
Auto Daylight Saving Time Correction
- Programmable Forward and Backward Dates
Dual Alarms with Hardware and Register Indicators
- Hardware Single Event or Pulse Interrupt Mode
128 Bytes of User SRAM
•I
2
C Interface
- 400kHz Data Transfer Rate
Pb-Free (RoHS Compliant)
Applications
Utility Meters
Control Applications
Vending Machines
White Goods
Consumer Electronics
NC
GND
AC
NC
1
2
3
4
8
7
6
5
V
DD
IRQ
SCL
SDA
Ordering Information
PART NUMBER
(Notes 1, 2, 3)
PART
MARKING V
DD
RANGE
TEMP RANGE
(°C)
PACKAGE
(Pb-Free)
PKG
DWG #
ISL12030IBZ 12030 IBZ 2.7V to 5.5V -40 to +85 8 Ld SOIC M8.15
NOTE:
1. Add “-T*” suffix for tape and reel. Please refer to TB347
for details on reel specifications.
2. These Intersil Pb-free plastic packaged products employ special Pb-free material sets, molding compounds/die attach materials, and 100% matte
tin plate plus anneal (e3 termination finish, which is RoHS compliant and compatible with both SnPb and Pb-free soldering operations). Intersil
Pb-free products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J STD-
020.
3. For Moisture Sensitivity Level (MSL), please see device information page for ISL12030
. For more information on MSL please see techbrief
TB363
.
Data Sheet May 5, 2011
N
O
T
RE
C
O
M
M
E
N
D
E
D
F
O
R
N
E
W
D
E
S
I
G
N
S
N
O
R
E
C
O
M
M
E
N
D
E
D RE
P
L
A
C
E
M
E
N
T
c
o
n
t
a
c
t
o
u
r
T
e
c
h
n
i
c
a
l
S
u
p
p
o
r
t
C
e
n
t
e
r
a
t
1
-
8
8
8
-
I
N
T
E
R
S
IL
o
r
w
w
w
.
i
n
t
e
r
s
i
l
.
c
o
m
/
t
s
c
2
FN6617.2
May 5, 2011
Block Diagram
I
2
C
INTERFACE
CONTROL
LOGIC
ALARM
RTC
DIVIDER
SDA
BUFFER
SCL
BUFFER
SDA
SCL
V
DD
IRQ
INTERNAL
SUPPLY
SECONDS
MINUTES
HOURS
DAY OF WEEK
DATE
MONTH
YEAR
USER
SRAM
CONTROL
REGISTERS
REGISTERS
GND
AC
AC INPUT
BUFFER
Functional Pin Descriptions
PIN
NUMBER SYMBOL DESCRIPTION
2GNDGround.
3ACAC Input. The AC input pin accepts either 50Hz of 60Hz AC 2.5V
P-P
sine wave signal.
5SDASerial Data. SDA is a bi-directional pin used to transfer serial data into and out of the device. It has an open drain
output and may be wire OR’ed with other open drain or open collector outputs.
6SCLSerial Clock. The SCL input is used to clock all serial data into and out of the device.
7IRQ
Interrupt Output. Open Drain active low output. Interrupt output pin to indicate alarm is triggered.
8V
DD
Power supply.
1, 4 NC No Connection. Do not connect to any electrical circuit, power or ground.
ISL12030
3
FN6617.2
May 5, 2011
Absolute Maximum Ratings Thermal Information
Voltage on V
DD
, SCL, SDA, AC, IRQ pins
(respect to ground) . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 6.0V
ESD Rating
Human Body Model (Per MIL-STD-883 Method 3014) . . . . .>2kV
Machine Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>200V
Recommended Operating Conditions
Temperature (T
A
) . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage (V
DD
) . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Thermal Resistance (Typical, Note 4)
JA
(°C/W)
8 Ld SOIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . -65°C to +150°C
Pb-free reflow profile . . . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTE:
4.
JA
is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
Operating Specifications Specifications apply for: V
DD
= 2.7V to 5.5V, T
A
= -40°C to +85°C, unless otherwise stated. Boldface limits
apply over the operating temperature range, -40°C to +85°C.
SYMBOL PARAMETER CONDITIONS
MIN
(Note 11)
TYP
(Note 6)
MAX
(Note 11) UNITS NOTES
V
DD
Main Power Supply 2.7 5.5 V
I
DD1
Supply Current V
DD
= 5V, SCL, SDA = V
DD
27 60 µA 7
V
DD
= 3V, SCL, SDA = V
DD
16 45 µA 7
I
DD2
Supply Current (I
2
C Communications
Active)
V
DD
= 5V 43 75 µA 5, 7
I
DD3
Supply Current for Timekeeping
at AC Input
V
DD
= 5.5V at T
A
= +25°C 9.0 18.0 µA 5, 7
I
LI
Input Leakage Current on SCL 1 µA
I
LO
I/O Leakage Current on SDA 1 µA
IRQ
(OPEN DRAIN OUTPUT)
V
OL
Output Low Voltage V
DD
= 5V, I
OL
= 3mA 0.4 V
V
DD
= 2.7V, I
OL
= 1mA 0.4 V
Power-Down Timing Specifications apply for: V
DD
= 2.7 to 5.5V, T
A
= -40°C to +85°C, unless otherwise stated. Boldface limits apply over
the operating temperature range, -40°C to +85°C.
SYMBOL PARAMETER CONDITIONS
MIN
(Note 11)
TYP
(Note 6)
MAX
(Note 11) UNITS NOTES
V
DD SR-
V
DD
Negative Slew Rate 10 V/ms 9
I
2
C Interface Specifications Specifications apply for: V
DD
= 2.7 to 5.5V, T
A
= -40°C to +85°C, unless otherwise stated. Boldface limits
apply over the operating temperature range, -40°C to +85°C.
SYMBOL PARAMETER TEST CONDITIONS
MIN
(Note 11)
TYP
(Note 6)
MAX
(Note 11) UNITS NOTES
V
IL
SDA and SCL Input Buffer LOW
Voltage
-0.3 0.3 x V
DD
V
V
IH
SDA and SCL Input Buffer HIGH
Voltage
0.7 x V
DD
V
DD
+ 0.3 V
Hysteresis SDA and SCL Input Buffer
Hysteresis
0.05 x V
DD
V
V
OL
SDA Output Buffer LOW Voltage,
Sinking 3mA
V
DD
= 5V, I
OL
= 3mA 0.4 V
ISL12030

ISL12030IBZ

Mfr. #:
Manufacturer:
Renesas / Intersil
Description:
Real Time Clock REAL TIME CLK W/ EEPROM 8LD
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet