ADuM1410/ADuM1411/ADuM1412 Data Sheet
Rev. M | Page 10 of 22
PACKAGE CHARACTERISTICS
Table 4.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)
1
R
I-O
10
12
Ω
Capacitance (Input to Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction to Case Thermal Resistance
Side 1 θ
JCI
33 °C/W Thermocouple located at center of package underside
Side 2 θ
JCO
28 °C/W
1
The device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM1410/ADuM1411/ADuM1412 have been approved by the organizations listed in Table 5. See Table 10 and the Insulation Lifetime
section for recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL CSA CQC VDE TÜV
Recognized Under
1577 Component
Recognition
Program
1
Approved under CSA
Component Acceptance
Notice 5A
Approved under
CQC11-471543-2012
Certified according to
DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12
2
Approved according to
IEC 60950-1:2005 and
EN 60950-1:2006
Single Protection,
3750 V rms
Isolation
Voltage
Basic insulation per
CSA 60950-1-03 and
IEC 60950-1, 800 V rms
(1131 V peak) maximum
working voltage
Basic insulation per
GB4943.1-2011, 600 V rms
(848 V peak) maximum
working voltage, tropical
climate, altitude ≤ 5000 m
Reinforced insulation,
560 V peak
3000 V rms reinforced isolation
at a 400 V rms working voltage,
3000 V rms basic isolation at a
600 V rms working voltage
Reinforced insulation
per CSA 60950-1-03 and
IEC 60950-1, 400 V rms
(566 V peak) maximum
working voltage
Reinforced insulation per
GB4943.1-2011, 380 V rms
(537 V peak) maximum
working voltage, tropical
climate, altitude ≤ 5000 m
File E214100 File 205078 File CQC14001108689 File 2471900-4880-0001 Certificate B 10 03 56232 006
1
In accordance with UL 1577, each ADuM1410/ADuM1411/ADuM1412 is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage
detection limit = 5 μA).
2
In accordance with DIN V VDE V 0884-10, each ADuM1410/ADuM1411/ADuM1412 is proof tested by applying an insulation test voltage ≥1050 V peak for 1 second
(partial discharge detection limit = 5 pC). The asterisk (*) marked on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 6.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 3750 V rms 1-minute duration
Minimum External Tracking (Creepage) L(I02) 7.7
1
mm min
Measured from input terminals to output terminals, shortest
distance path along package body
Minimum External Air Gap (Clearance) L(I01) 7.7 mm min
Measured from input terminals to output terminals, shortest
distance through air
Minimum Clearance in the Plane of the
Printed Circuit Board (PCB Clearance)
L(PCB) 8.1
2
mm min
Measured from input terminals to output terminals, shortest
distance through air, line of sight, in the PCB mounting plane
Minimum Internal Gap (Internal Clearance) 0.017 mm min Insulation distance through insulation
Tracking Resistance (Comparative Tracking
Index)
CTI >400 V DIN IEC 112/VDE 0303 Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1)
1
Clearance and creepage measured by VDE is >8 mm for SOIC wide packages.
2
This value is for information only, to aid in PCB design. Package clearance is identical to creepage as specified in L(I02).
Data Sheet ADuM1410/ADuM1411/ADuM1412
Rev. M | Page 11 of 22
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12 INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation within the safety limit data only. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marked on packages denotes DIN V VDE V 0884-10 approval.
Table 7.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
560 V peak
Input-to-Output Test Voltage, Method B1
V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1050 V peak
Input-to-Output Test Voltage, Method A V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
After Environmental Tests Subgroup 1 896 V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 672 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 seconds V
TR
4000 V peak
Safety Limiting Values
Maximum value allowed in the event of a failure;
see Figure 4
Case Temperature T
S
150 °C
Side 1 Current I
S1
265 mA
Side 2 Current I
S2
335 mA
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Ω
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
350
300
250
200
150
100
50
50 100 150 200
SIDE #1
SIDE #2
06580-007
Figure 4. Thermal Derating Curve, Dependence of Safety Limiting Values
with Case Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter Symbol Min Max Unit
Operating Temperature T
A
−40 +105 °C
Supply Voltages
1
V
DD1
, V
DD2
2.7 5.5 V
Input Signal Rise and Fall Times 1.0 ms
1
All voltages are relative to their respective ground. See the DC Correctness
and Magnetic Field Immunity section for information on immunity to external
magnetic fields.
ADuM1410/ADuM1411/ADuM1412 Data Sheet
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 9.
Parameter Rating
Storage Temperature (T
ST
) Range −65°C to +150°C
Ambient Operating Temperature
(T
A
) Range
−40°C to +105°C
Supply Voltages (V
DD1
, V
DD2
)
1
−0.5 V to +7.0 V
Input Voltages (V
IA
, V
IB
, V
IC
, V
ID
, V
CTRL1
,
V
CTRL2
, V
DISABLE
)
1, 2
−0.5 V to V
DDI
+ 0.5 V
Output Voltages (V
OA
, V
OB
, V
OC
, V
OD
)
1, 2
−0.5 V to V
DDO
+ 0.5 V
Average Output Current per Pin
3
Side 1 (I
O1
) −18 mA to +18 mA
Side 2 (I
O2
) −22 mA to +22 mA
Common-Mode Transients
4
−100 kV/μs to +100 kV/μs
1
All voltages are relative to their respective ground.
2
V
DDI
and V
DDO
refer to the supply voltages on the input and output sides of a
given channel, respectively. See the PC Board Layout section.
3
See Figure 4 for maximum rated current values for various temperatures.
4
Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the absolute maximum ratings may cause
latch-up or permanent damage.
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
ESD CAUTION
Table 10. Maximum Continuous Working Voltage
1
Parameter Max Unit Constraint
AC Voltage, Bipolar Waveform 565 V peak
50-year minimum lifetime
AC Voltage, Unipolar Waveform
Basic Insulation 1131 V peak
Maximum approved working voltage per IEC 60950-1
Reinforced Insulation 560 V peak Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
DC Voltage
Basic Insulation 1131 V peak
Maximum approved working voltage per IEC 60950-1
Reinforced Insulation 560 V peak Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1
Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.
Rev. M | Page 12 of 22

ADUM1412ARWZ

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Digital Isolators Digital Quad-CH
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union