Data Sheet ADuM2250/ADuM2251
Rev. D | Page 5 of 16
PACKAGE CHARACTERISTICS
Table 3.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)
1
R
I-O
10
12
Ω
Capacitance (Input to Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance C
I
4.0 pF
IC Junction to Ambient Thermal Resistance θ
JA
45 °C/W
Thermocouple located at center of
package underside
1
The device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
REGULATORY INFORMATION
The ADuM2250/ADuM2251 are approved by the organizations listed in Table 4.
Table 4.
UL CSA CQC VDE
Recognized Under
UL 1577 Component
Recognition Program
1
Approved under CSA Component
Acceptance Notice 5A
Approved under CQC11-471543-2012
Certified according to
DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
Single Protection,
5000 V rms Isolation
Voltage
Basic insulation per CSA 60950-1-07
and IEC 60950-1, 600 V rms
(849 V peak) maximum
working voltage
Basic insulation per GB4943.1-2011,
600 V rms (848 V peak) maximum
working voltage, tropical climate,
altitude ≤ 5000 m
Reinforced insulation,
849 V peak
RW-16 package: reinforced
insulation per CSA 60950-1-07 and
IEC 60950-1, 380 V rms (537 V peak)
maximum working voltage
RW-16 package: reinforced insulation
per GB4943.1-2011, 380 V rms (537 V peak)
maximum working voltage,
tropical climate, altitude ≤ 5000 m
Reinforced insulation per
IEC 60601-1, 125 V rms (176 V peak)
maximum working voltage
RI-16-2 package: reinforced
insulation per CSA 60950-1-07 and
IEC 60950-1, 400 V rms (565 V peak)
maximum working voltage
RI-16 package: reinforced insulation
per 400 V rms (565 V peak) maximum
working voltage, tropical climate,
altitude ≤ 5000 m
Reinforced insulation per
IEC 60601-1, 250 V rms (353 V peak)
maximum working voltage
File E214100 File 205078 File CQC14001117251 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM2250/ADuM2251 is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec (current leakage detection limit = 10 μA).
2
In accordance with DIN V VDE V 0884-10 (VDE V 0884-10):2006-12, each ADuM2250/ADuM2251 is proof tested by applying an insulation test voltage ≥ 1590 V peak for 1 sec
(partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 5.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 8.0 min mm
Distance measured from input terminals to output
terminals, shortest distance through air along the
PCB mounting plane, as an aid to PC board layout
Minimum External Tracking (Creepage) L(I02)
Measured from input terminals to output
terminals, shortest distance path along body
RW-16 Package 7.7 min mm
RI-16-2 Package 8.3 min mm
Minimum Internal Distance (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303, Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1)