NMUSB2022PMC
2 MOPP Powered Dual Port USB Data Isolator
KDC_NMUSB2022PMC.A03 Page 2 of 8
www.murata-ps.com/support
DC-DC CHARACTERISTICS
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range Continuous operation 4.5 5 5.5 V
Current (hub inactive) 5V input 70 mA
Current (hub active) 0% load 5V input 110 mA
Current 100% load 5V input 1.3 A
Input reflected ripple current 5V input 26 mA
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Downstream voltages 5V output 4.75 5 5.25 V
Transient response
Peak deviation (0-50-0% & 50-100-50% swing) -5 +3 %V
out
Settling time 40 400 µs
MODULE CHARACTERISTICS
TEMPERATURE CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Operation See derating curve -40 85
°C
Storage -55 125
Product temperature rise above ambient 100% Load, Nom V
IN, Still Air (measured on transformer core) 30 32
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation test voltage
Production tested for 1 second 4000
VAC
Qualification tested for 1 minute 4000
Resistance Viso = 1kVDC 1 GΩ
GENERAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Leakage current 250 VAC 50Hz 1.3
µA
Common mode transient immunity 25 kV/ s
MTTF
Calculated using MIL-HDBK-217 FN2 calculation model with nominal input
voltage at full load, 25°C ambient temperature
600 kHrs
Calculated using Telecordia SR-332 calculation model with nominal input
voltage at full load, 25°C ambient temperature
3300 kHrs
ABSOLUTE MAXIMUM RATINGS
Parameter Conditions Value
Short-circuit protection Downstream USB 5V Continuous
Input voltage Upstream USB 5V supply 5.5V