TS2007 Absolute maximum ratings and operating conditions
Doc ID 13123 Rev 4 3/29
1 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol Parameter Value Unit
V
CC
Supply voltage
(1)
1. All voltage values are measured with respect to the ground pin.
6V
V
i
Input voltage
(2)
2. The magnitude of the input signal must never exceed V
CC
+ 0.3 V / GND - 0.3 V.
GND to V
CC
V
T
oper
Operating free air temperature range -40 to + 85 °C
T
stg
Storage temperature -65 to +150 °C
T
j
Maximum junction temperature 150 °C
R
thja
Thermal resistance junction to ambient
(3)
3. The device is protected in case of over temperature by a thermal shutdown active @ 150 °C.
200 °C/W
Pd Power dissipation Internally limited
(4)
4. Exceeding the power derating curves during a long period will cause abnormal operation.
ESD HBM: human body model 2 kV
ESD MM: machine model 200 V
Latch-up Latch-up immunity Class A
Lead temperature (soldering, 10 sec) 260 °C
R
L
Minimum load resistor 3.2 Ω
Table 2. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage 2.4 to 5.5 V
V
I
Input voltage range GND to V
CC
V
V
ic
Input common mode voltage
(1)
1. I V
oo
I ≤ 35 mV max with both differential gains.
GND+0.15 V to V
CC
-0.7 V V
V
STBY
Standby voltage input
(2)
Device ON
Device OFF
2. Without any signal on V
STBY
, the device is in standby (internal 300 kΩ pull down resistor).
1.4 ≤ V
STBY
≤ V
CC
GND
≤ V
STBY
≤ 0.4
(3)
3. Minimum current consumption is obtained when V
STBY
= GND.
V
GS
Gain select input:
Gain =12dB
Gain = 6dB
GND
≤ V
GS
≤ 0.4
1.4 ≤ V
GS
≤ V
CC
V
R
L
Load resistor ≥ 4 Ω
R
thja
Thermal resistance junction to ambient
(4)
4. When mounted on 4-layer PCB.
40 °C/W