Electrical characteristics STGIF7CH60TS-L
10/25 DocID026580 Rev 6
Note: Comparator remains enabled even if V
CC
is in the UVLO condition but higher than 4 V.
Temperature sensor output
V
TSO
Temperature sensor output
voltage
T
j
= 25 °C 1.4 V
I
TSO_SNK
Temperature sensor sink
current capability
0.1 mA
I
TSO_SRC
Temperature sensor source
current capability
4mA
1. Applied between HINx, LINx and GND for x = U, V, W
Table 9. Sense comparator (V
CC
= 15 V, unless otherwise is specified)
Symbol Parameter Test condition Min Typ Max Unit
I
CIN
CIN input bias current V
CIN
=1V -0.2 0.2 µA
V
ref
Internal reference voltage 460 510 560 mV
V
OD
Open drain low level output
voltage
I
od
= 5mA 500 mV
t
CIN_SD
C
IN
comparator delay to SD
SD
pulled to 5V through
R
SD
=10k; measured applying a
voltage step 0-1V to Pin CIN
50% CIN to 90% SD
150 230 320 ns
SR
SD
SD fall slew rate
SD
pulled to 5V through
R
SD
=10k; C
L
=1nF through SD
and ground;
90% SD
to 10% SD
25 V/µs
Table 8. Control / protection parts (continued)
Symbol Parameter Test condition Min Typ Max Unit
DocID026580 Rev 6 11/25
STGIF7CH60TS-L Fault management
25
4 Fault management
The device integrates an open-drain output connected to SD Pin. As soon as a fault occurs
the open-drain is activated and LVGx outputs are forced low. Two types of fault can be
detected:
Overcurrent (OC) sensed by the internal comparator (see more detail in Section 4.2:
Smart shutdown function);
Undervoltage on supply voltage (V
CC
);
Each fault enables the SD open drain for a different time; refer to the following Table 10:
Fault timing.
The device actually device remains in a fault condition (SD
at low logic level and LVGx
outputs disabled) for a time also depending on RC network connected to SD
pin. The
network generates a time contribution that is added to the internal value.
Figure 4. Overcurrent timing (without contribution of RC network on SD
)
Table 10. Fault timing
Symbol Parameter Event time
SD open-drain enable
time result
OC Over-current event
20 s 20 s
20µs OC time
UVLO
Under-voltage lock out
event
50 s 50 µs
50 µs
until the VCC_LS exceed the
VCC_LS UV turn ON threshold
UVLO time
*,3*)65
Fault management STGIF7CH60TS-L
12/25 DocID026580 Rev 6
Figure 5. UVLO timing (without contribution of RC network on SD)
4.1 TSO output
The device integrates temperature sensor. A voltage proportional to die temperature is
available on TSO pin. When this function is not used the Pin can be left floating.
4.2 Smart shutdown function
The device integrates a comparator committed to the fault sensing function. The comparator
input can be connected to an external shunt resistor in order to implement a simple
overcurrent detection function.
The output signal of the comparator is fed to an integrated MOSFET with the open drain
output available on SD
input. When the comparator triggers, the device is set to the
shutdown state and its outputs are all set to low.
*,3*)65

STGIF7CH60TS-L

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
IGBT Modules SLLIMM 2nd series IPM, 3-phase inverter, 10 A, 600 V short-circuit rugged IGBTs
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet