THE INFORMATION CONTAINED IN THIS DRAWING IS CONFIDENTIAL AND MAY NOT BE
DISCLOSED WITHOUT WRITTEN CONSENT FROM SOURIAU USA, INC.
THIS DRAWING IS A CONTROLLED DOCUMENT FOR SOURIAU USA, INC.
IT IS SUBJECT TO CHANGE WITHOUT NOTIFICATION.
CONTACT THE DOCUMENT CONTROL CENTER FOR THE LATEST REVISION.
PRO-E
DWG. NO.
ANGLES#1$
#.010 [#0.25]
THREE PLACES
#.02 [#0.5]
TWO PLACES
#.1 [#3]
ONE PLACE
INCH [mm]
No. OF PLACES
TOLERANCES
UNLESS OTHERWISE SPECIFIED
THIRD ANGLE PROJECTION
LINEAR
MEASURE:
4 OF 6
www.souriau.com
INTERPRET THIS DRAWING IN ACCORDANCE
WITH ASME Y14.5M - 1994.
U
SA94843
REVDRAWING NO.
CUSTOMER
DRAWING SCALE: 1:1
11-15-10
QC : DK
APPROVAL
11-15-10
MFG : DH
10-13-92
DSGN : JDA
11-15-10
CHKD : SDH
11-15-10
DRAWN:
VKP
SIZE: ACAGE NO.: 09922
RBGT__ & RBMT__ (SEE TABLE, SHT. 2)
CAT NO.
TRACKS, GROUNDING & MOUNTING
DRAWING TITLE
---
ALL REV. RECORDED ON SHT. 1
--- ---
REV DESCRIPTION
BY
DATE
CHKD
DATE
SA94843
PERFORMANCE CHARACTERISTICS
MECHANICAL:
MAGNETIC PERMEABILITY: ALL MATERIALS DO NOT EXHIBIT A RELATIVE MAGNETIC
PERMEABILITY OF GREATER THAN 2 IN ACCORDANCE
WITH MIL-T-81714, PARA. 4.6.15.
REF: MIL-STD-1344, METHOD 3006.
MAINTENANCE AGING: IN ACCORDANCE WITH MIL-T-81714, PARA. 4.6.3.
CONTACT INSERTION/REMOVAL FORCE: 10 LBS [44,4N] MAX. IN ACCORDANCE WITH
MIL-T-81714, PARA.4.6.3
CONTACT RETENTION: 20 LBS [88,9N] MIN. IN ACCORDANCE WITH
MIL-T-81714, PARA. 4.6.4. AXIAL DISPLACEMENT DOES
NOT EXCEED .012 [0,30].
REF: MIL-STD-1344, METHOD 2007.
PROBE DAMAGE: IN ACCORDANCE WITH MIL-T-81714, PARA. 4.6.2.
RETENTION SYSTEM FLUID IMMERSION: IN ACCORDANCE WITH MIL-T-81714, PARA. 4.6.23.
INTERNAL CONTACT DURABILITY: 100 CYCLES OF MATING AND UNMATING TO DEPTH OF
MECHANICAL AND ELECTRICAL ENGAGEMENT
IN ACCORDANCE WITH MIL-T-81714, PARA. 4.6.19.
OVERSIZE PIN CONTACT PROTECTION: GROUNDING MODULE DESIGNED TO PREVENT ENTRANCE
OF AN OVERSIZE TEST PIN OF .070 [1,78]
IN ACCORDANCE WITH MIL-T-81714, PARA. 4.6.20.
CONTACT WALKOUT: IN ACCORDANCE WITH MIL-T-81714, PARA. 4.6.22.
REF: MIL-STD-1549.
SEE DRAWING SE94834 FOR
FEEDBACK MODULE
FEEDBACK MODULE INSTALLED IN
GROUNDING AND MOUNTING TRACKS
SCALE 1:1