■ LIGHT AXIS ADJUSTMENT WITH FLASHING FUNCTION
E3X-A❏❏/-F❏❏/-VG❏❏
Stable Operation Indicator
(Green Indicator)
With this function, the E3X checks changes in environment
conditions (especially a change in the ambient temperature) and
self-diagnoses the resistance against the changes. The result is
shown by the indicators or an output signal.
Improper Light Axis
2. Adjust the light axis by moving the fiber with
the light flashing.
Proper Light Axis
3. Set the mode selector to L-ON or D-ON after the
light axis is adjusted.
Mode Selector
Flashing
Light axis
adjusted
Light ON with
no flashing
■ SELF-DIAGNOSTIC FUNCTION
Light Reception Indicator
(Red Indicator)
Displays
● Stable Operation Indicator: Changes in environmental
conditions (changes in the ambient temperature, the
operating voltage, or the volume of dust) are checked and
the resistance against them are self-diagnosed. The result
is shown via the indicator.
● Light Reception Indicator: The amount of light received is
shown by this indicator.
Output:
● The resistance against changes in environmental
conditions is shown by the indicator and the result is
output.
1. Set the mode selector to SET.
*If the self-diagnostic output is ON when the sensing object is
moving at low speed, use the E3X with an ON-delay timer circuit.
Tip of the fiber connected
to the light source side in
the SET mode
Flashing
Flashing
0.3 s min.
0.3 s min.
ON
OFF
ON
OFF
Control output
(L, ON)
Self-diagnostic
output*
Indicator
Operating level x 1.2
Operating level
Operating level x 0.8
Amount of
light
1.2
1
0.8
Red
Green
Green
light ON
Green