User Manual AS5x61/AS5x62 Programming
www.ams.com
Revision 1.0 / 10/31/12
page 6/14
16) For calibrating the T1 and T2 voltages of the OutputDac, turn on,
and start the calibration. This calibration has to be used after the point 5 to point 15.
17) Additional to calculate the programming data with the calibrated DAC
Values.
18) To program an AS5262 ( DualDie) Device, redo point 5 to point 17 on page
19) Click
20) Set to activate the internal filter. Default setting is no filter. For
further information please read AS5x62 Datasheet.
21) Set to choose between normal airgap range or extended airgap
range. For further information please read AS5x62 Datasheet.
22) To program an AS5262(DualDie) Device, redo point 20 and 21 for the Top Device.
23) Two actions can happen at this point.
a. You can confirm that the entered data operates as expected. Go to Step 23.
b. You can go straight to burning the configuration in to the AS5x62. Go to Step 31.
24) During this procedure, DO NOT click on
25) Click
26) Click
27) Check if write/read Chksum is green
28) To program an AS5262(DualDie) Device, redo point 20 and 21 for the Top Device.
29) Click to check with an oscilloscope if your trimming is what you
expected.
30) If satisfied with the results go to Step 31, otherwise, go to Step19.
31) Reset the device. You have to push the reset button on the UART Interface board by hand.
This will reset the programming configuration.
32) Go to Step 4 to repeat procedure to change unacceptable parameters.
User Manual AS5x61/AS5x62 Programming
www.ams.com
Revision 1.0 / 10/31/12
page 7/14
**** Permanent Programming of AS5x62 beyond this point ****
33) Reset the device.
34) Select
35) Click This transfers all data to “Programming Mode” screen.
36) For programming the A5262(DualDie), redo point 34 and 35 at
37) Click
38) Click This will cause the AS5x62 to permanently enter into Output Mode when
power is applied to it.
39) Click
40) Click
41) Check if write/read Chksum is green
42) To program an AS5262(DualDie) Device, redo step 38 to step 41 for the Top Device.
43) Click A message will appear.
44) Click yes to accept. CAUTION: Once this is done, the AS5x62 will permanently be
programmed.
45) Once the message disappears, the part is programmed.
46) Confirm proper operation by applying a scope or multimeter to VOUT.
User Manual AS5x61/AS5x62 Programming
www.ams.com
Revision 1.0 / 10/31/12
page 8/14
4. AS5x61 Programming
1) Connect AS5x61/AS5x62 to UART Interface board or to communication equipment.
Use VCC, GND and OUT for the communication. If the ams UART Interface board is
used, please connect an external 5V Powersupply to the board.
2) Start AS5x61/AS5x62 Evaluation Software
Figure 1 AS5x6y GUI
3) Choose the right device AS5162(singleDIE) or AS5262(dualDIE)
4) Click
5) Enter beginning angle, T1. Two methods are possible:
a. Manually enter an initial position value into “T1 Cordic” field or “T1 (°),or

AS5X6X-EK-ST

Mfr. #:
Manufacturer:
ams
Description:
Magnetic Sensor Development Tools AS5x6x Eval Kit 4 Adapter Boards USB
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet