General Description
The DS75LV low-voltage (1.7V to 3.7V) digital thermometer
and thermostat provides 9, 10, 11, or 12-bit digital temperature
readings over a -55°C to +125°C range with ±2°C accuracy
over a -25°C to +100°C range. At power-up, the DS75LV
defaults to 9-bit resolution for software compatibility with the
LM75. Communication with the DS75LV is achieved through
a simple 2-wire serial interface.
The DS75LV thermostat has a dedicated open-drain output
(OS) and programmable fault tolerance, which allows the
user to define the number of consecutive error conditions that
must occur before OS is activated. There are two thermostatic
operating modes that control thermostat operation based on
user-defined trip-points (T
OS
and T
HYST
).
Applications
Personal Computers
Cellular Base Stations
Ofce Equipment
Any Thermally Sensitive System
Benets and Features
Extend Performance Range with Low-Voltage,
1.7V to 3.7V Operating Range
Maximize System Accuracy in Broad Range of
Thermal Management Applications
Measures Temperature from -55°C to +125°C
(-67°F to +257°F)
±2°C Accuracy over a -25°C to 100°C Range
User-Congurable Resolution from 9 Bits (Default)
to 12 Bits (0.5°C to 0.0625°C)
Easy Upgrade to LM75: Pin and Software Compatible
Simplify Distributed Temperature-Sensing
Applications with Multidrop Capability
Up to Eight DS75LVs Can Operate on 2-Wire Bus
Increase Reliability and System Robustness
Internally Filtered Data Lines for Noise Immunity
(50ns Deglitch)
Bus Timeout Feature Prevents Lockup on 2-Wire
Interface
Minimize Power Consumption with Built-In Shutdown
Mode
Flexible User-Defined Thermostatic Modes with
Programmable Fault Tolerance
Ordering Information appears at end of data sheet.
19-7469; Rev 4; 3/16
DS75LV Digital Thermometer and Thermostat
Functional Block Diagram
TOS AND THYST
REGISTERS
CONFIGURATION
REGISTER
TEMPERATURE
REGISTER
OVERSAMPLING
MODULATOR
PRECISION
REFERENCE
DIGITAL
DECIMATOR
ADDRESS
AND
I/O CONTROL
A1
A2
A0
SCL
SDA
V
DD
GND
THERMOSTAT
COMPARATOR
R
P
OS
DS75LV
Voltage on V
DD
, Relative to Ground ....................-0.3V to +4.0V
Voltage on Any Other Pin, Relative to Ground ....-0.3V to +6.0V
Operating Temperature Range ......................... -55°C to +125°C
Storage Temperature Range ............................ -55°C to +125°C
Lead Temperature (soldering, 10s) .................................+260°C
(1.7V ≤ V
DD
3.7V, T
A
= -55°C to +125°C, unless otherwise noted.)
(1.7V ≤ V
DD
3.7V, T
A
= -55°C to +125°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN MAX UNITS
Supply Voltage V
DD
1.7 3.7 V
Thermometer Error (Note 1) T
ERR
-25 to +100 ±2.0
°C
-55 to +125 ±3.0
Input Logic-High V
IH
(Note 2) 0.7 x V
DD
5.5 V
Input Logic-Low V
IL
(Note 2) -0.5 0.3 x V
DD
V
SDA Output Logic Low Voltage
(Note 2)
V
OL1
3mA sink current 0 0.4
V
V
OL2
6mA sink current 0 0.6
OS Saturation Voltage V
OL
4mA sink current (Notes 1, 2) 0.8 V
Input Current Each I/O Pin 0.4 < V
I/O
< 0.9 x V
DD
-10 +10 µA
I/O Capacitance C
I/O
10 pF
Standby Current I
DD1
(Notes 3, 4) 2 µA
Active Current (Notes 3, 4) I
DD
Active temp conversions 1000
µA
Communication only 100
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Resolution 9 12 Bits
Temperature Conversion Time t
CONVT
9-bit conversions 25
ms
10-bit conversions 50
11-bit conversions 100
12-bit conversions 200
SCL Frequency f
SCL
400 kHz
Bus Free Time Between a
STOP and START Condition
t
BUF
(Note 5) 1.3 µs
START and Repeated START
Hold Time from Falling SCL
t
HD:STA
(Notes 5, 6) 600 ns
DS75LV Digital Thermometer and Thermostat
www.maximintegrated.com
Maxim Integrated
2
Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
DC Electrical Characteristics
AC Electrical Characteristics
(1.7V ≤ V
DD
3.7V, T
A
= -55°C to +125°C, unless otherwise noted.)
Note 1: Internal heating caused by OS loading causes the DS75LV to read approximately 0.5°C higher if OS is sinking the max
rated current.
Note 2: All voltages are referenced to ground.
Note 3: I
DD
specified with V
DD
at 3.0V and SDA, SCL = 3.0V, 0°C to +70°C.
Note 4: I
DD
specified with OS pin open.
Note 5: See Figure 2 for timing diagram. All timing is referenced to 0.9 x V
DD
and 0.1 x V
DD
.
Note 6: After this period, the first clock pulse is generated.
Note 7: The DS75LV provides an internal hold time of at least 75ns on the SDA signal to bridge the undefined region of SCL’s
falling edge.
Note 8: This timeout applies only when the DS75LV is holding SDA low. Other devices can hold SDA low indefinitely and the
DS75LV does not reset.
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Low Period of SCL t
LOW
(Note 5) 1.3 µs
High Period of SCL t
HIGH
(Note 5) 0.6 µs
Repeated START Condition
Setup Time to Rising SCL
t
SU:STA
(Note 5) 600 ns
Data-Out Hold Time from
Falling SCL
t
HD:DAT
(Notes 5, 7) 0 0.9 µs
Data-In Setup Time to Rising
SCL
t
SU:DAT
(Note 5) 100 ns
Rise Time of SDA and SCL
(Receive)
t
R
(Note 5) 1000 ns
Fall Time of SDA and SCL
(Receive)
t
F
(Note 5) 300 ns
Spike Suppression Filter Time
(Deglitch Filter)
t
SS
0 50 ns
STOP Setup Time to Rising
SCL
t
SU:STO
(Note 5) 600 ns
Capacitive Load for Each Bus
Line
C
B
400 pF
Input Capacitance C
I
5 pF
Serial Interface Reset Time t
TIMEOUT
SDA time low (Note 8) 75 325 ms
DS75LV Digital Thermometer and Thermostat
www.maximintegrated.com
Maxim Integrated
3
AC Electrical Characteristics (continued)

DS75LVS+

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Board Mount Temperature Sensors Low-Voltage Digital
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet