ADuM260N/ADuM261N/ADuM262N/ADuM263N Data Sheet
Rev. 0 | Page 10 of 23
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Undervoltage Lockout UVLO
Positive V
DDx
Threshold V
DDxUV+
1.6 V
Negative V
DDx
Threshold V
DDxUV−
1.5 V
V
DDx
Hysteresis V
DDxUVH
0.1 V
AC SPECIFICATIONS
Output Rise/Fall Time t
R
/t
F
2.5 ns 10% to 90%
Common-Mode Transient Immunity
7
|CM
H
| 75 100 kV/µs
V
Ix
= V
DDx
, V
CM
= 1000 V,
transient magnitude = 800 V
|CM
L
| 75 100 kV/µs
V
Ix
= 0 V, V
CM
= 1000 V,
transient magnitude = 800 V
1
150 Mbps is the highest data rate that can be guaranteed, although higher data rates are possible.
2
I
Ox
is the Channel x output current, where x = A, B, C, D, E, or F.
3
V
IxH
is the input side logic high.
4
V
IxL
is the input side logic low.
5
V
I
is the voltage input.
6
N0 refers to the ADuM260N0/ADuM261N0/ADuM262N0/ADuM263N0 models. N1 refers to the ADuM260N1/ADuM261N1/ADuM262N1/ADuM263N1 models. See the
Ordering Guide section.
7
|CM
H
| is the maximum common-mode voltage slew rate that can be sustained while maintaining the voltage output (V
O
) > 0.8 V
DDx
. |CM
L
| is the maximum common-
mode voltage slew rate that can be sustained while maintaining V
O
> 0.8 V. The common-mode voltage slew rates apply to both rising and falling common-mode
voltage edges.
Table 8. Total Supply Current vs. Data Throughput
1 Mbps 25 Mbps 100 Mbps
Parameter Symbol Min Typ Max Min Typ Max Min Typ Max Unit
SUPPLY CURRENT
ADuM260N
Supply Current Side 1 I
DD1
10.2 15.2 11.3 18.2 15.9 23.9 mA
Supply Current Side 2 I
DD2
3.3 5.3 4.8 7.2 9.8 17.9 mA
ADuM261N
Supply Current Side 1 I
DD1
8.7 13.9 10 16.2 14.6 23.4 mA
Supply Current Side 2 I
DD2
4.9 8.6 6.4 11 11.4 20.1 mA
ADuM262N
Supply Current Side 1 I
DD1
8.0 12.5 9.2 14.2 13.9 23 mA
Supply Current Side 2 I
DD2
6.4 10.1 7.7 12 12.4 20.1 mA
ADuM263N
Supply Current Side 1 I
DD1
7.0 11.8 8.3 13.7 13.3 20.7 mA
Supply Current Side 2 I
DD2
8.2 13.3 9.5 15 14.5 21 mA
Data Sheet ADuM260N/ADuM261N/ADuM262N/ADuM263N
Rev. 0 | Page 11 of 23
INSULATION AND SAFETY RELATED SPECIFICATIONS
For additional information, see http://www.analog.com/icouplersafety.
Table 9.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (Clearance) L (I01) 8.3 mm min
Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L (I02) 8.3 mm min
Measured from input terminals to output terminals,
shortest distance path along body
Minimum Clearance in the Plane of the Printed
Circuit Board (PCB Clearance)
L (PCB) 8.3 mm min
Measured from input terminals to output terminals,
shortest distance through air, line of sight, in the PCB
mounting plane
Minimum Internal Gap (Internal Clearance) 25.5 m min Minimum distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303 Part 1
Material Group II Material Group (DIN VDE 0110, 1/89, Table 1)
PACKAGE CHARACTERISTICS
Table 10.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)
1
R
I-O
10
13
Capacitance (Input to Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction to Ambient Thermal Resistance θ
JA
45 °C/W Thermocouple located at center of package underside
1
The device is considered a 2-terminal device: Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
See Table 15 and the Insulation Lifetime section for details regarding recommended maximum working voltages for specific cross-
isolation waveforms and insulation levels.
Table 11.
UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending)
Recognized Under UL 1577
Component Recognition Program
1
Approved under CSA Component
Acceptance Notice 5A
Certified according to
DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
Certified under
CQC11-471543-2012,
GB4943.1-2011:
Single Protection, 5000 V rms Isolation
Voltage
CSA 60950-1-07+A1+A2 and IEC
60950-1, second edition, +A1 + A2:
Reinforced insulation, V
IORM
=
849 V peak, V
IOSM
= 10 kV peak
Basic insulation at
830 V rms (1174 V peak)
Basic insulation at 830 V rms
(1174 V peak)
Basic insulation, V
IORM
=
849 V peak, V
IOSM
= 16 kV peak
Reinforced insulation at
415 V rms (587 V peak)
Reinforced insulation at 415 V rms
(587 V peak)
Tropical climate, altitude
≤5000 meters
IEC 60601-1 Edition 3 + A1 two means
of patient protection (2 MOPP),
261 V rms (369 V peak)
CSA 61010-1-12 and IEC 61010-1 third
edition:
Basic insulation at 300 V rms mains,
830 V rms secondary (1174 V peak)
File E214100 File 205078 File 2471900-4880-0001 File (pending)
1
In accordance with UL 1577, each ADuM260N/ADuM261N/ADuM262N/ADuM263N in the RI-16 wide body (SOIC_IC) package is proof tested by applying an insulation
test voltage ≥ 6000 V rms for 1 sec.
2
In accordance with DIN V VDE V 0884-10, each ADuM260N/ADuM261N/ADuM262N/ADuM263N in the RI-16 wide body (SOIC_IC) package is proof tested by applying an
insulation test voltage ≥ 1592 V peak for 1 sec (partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10
approval.
ADuM260N/ADuM261N/ADuM262N/ADuM263N Data Sheet
Rev. 0 | Page 12 of 23
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Protective circuits ensure the maintenance
of the safety data. The * marking on packages denotes DIN V VDE V 0884-10 approval.
Table 12.
Description Test Conditions/Comments Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to IV
For Rated Mains Voltage ≤ 600 V rms I to III
Climatic Classification 40/125/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
849 V peak
Input to Output Test Voltage, Method B1
V
IORM
× 1.875 = V
pd (m)
, 100% production test,
t
ini
= t
m
= 1 sec, partial discharge < 5 pC
V
pd (m)
1592 V peak
Input to Output Test Voltage, Method A V
pd (m)
After Environmental Tests Subgroup 1
V
IORM
× 1.5 = V
pd (m)
, t
ini
= 60 sec, t
m
= 10 sec,
partial discharge < 5 pC
1274 V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
pd (m)
, t
ini
= 60 sec, t
m
= 10 sec,
partial discharge < 5 pC
1019 V peak
Highest Allowable Overvoltage V
IOTM
8000 V peak
Surge Isolation Voltage Basic
V
PEAK
= 10 kV, 1.2 µs rise time, 50 µs,
50% fall time
V
IOSM
16,000 V peak
Surge Isolation Voltage Reinforced
V
PEAK
= 10 kV, 1.2 µs rise time, 50 µs,
50% fall time
V
IOSM
10,000 V peak
Safety Limiting Values
Maximum value allowed in the event of a
failure (see Figure 5)
Maximum Junction Temperature T
S
150 °C
Total Power Dissipation at 25°C P
S
2.78 W
Insulation Resistance at T
S
R
S
>10
9
3.0
2.5
2.0
1.5
0.5
1.0
0
020015010050
SAFE LIMITING POWER (W)
AMBIENT TEMPERATUREC)
14998-005
Figure 5. Thermal Derating Curve, Dependence of Safety Limiting Values
with Ambient Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 13.
Parameter Symbol Rating
Operating Temperature T
A
−40°C to +125°C
Supply Voltages V
DD1
, V
DD2
1.7 V to 5.5 V
Input Signal Rise and Fall Times 1.0 ms

ADUM262N1BRIZ-RL

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Digital Isolators Robust 5kV 6 CH Digital ISO 4/2
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union