PMC-05V015W1AA

TECHNICAL DATASHEET
PMC Panel Mount Power Supply
5V 15W 1
Phase
/ PMC-05V015W1AA
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (March 2013, Rev. 00)
7
De-rating VS AC input voltage
Assembly & Installation
Mounting
Mounting holes for power supply assembly onto the mounting surface. Power supply shall be mounted on minimum 2 mounting
holes using M3 screw minimum 5 mm length.
The power supply shall be mounted on minimum 2 mounting holes using M3 screw only. The screw penetration into the chassis
must be 2 mm.
Connector.
This surface belongs to customer’s end system or panel where the power supply is mounted.
Installation
No output power de-rating across the entire
input voltage range
keep a safe distance between the screw and internal components.
Recommended mounting tightening torque : 4~8Kgf.cm
Fig. 2 Mounting Orientation
TECHNICAL DATASHEET
PMC Panel Mount Power Supply
5V 15W 1
Phase
/ PMC-05V015W1AA
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (March 2013, Rev. 00)
8
Safety Instructions
Functions
Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
Start-up Time
The time required for the output voltage to reach 90% of its set value, after the input voltage is applied.
Rise Time
The time required for the output voltage to change from 10% to 90% of its set value.
Hold-up Time
Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time
required for the output to reach 95% of its set value, after the input voltage is removed.
To ensure sufficient convection cooling, always maintain a safety distance of >20mm from all ventilated surfaces while the
device is in operation.
The device is not recommended to be placed on low thermal conductive surface, for example, plastics.
Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power
supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!
Do not touch the terminals while power is being supplied. Risk of electric shock.
Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause: -
- Electric shock; Safety Hazard; Fire; Product failure
Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device,
remove L and N connections before removing the Earth connection.
TECHNICAL DATASHEET
PMC Panel Mount Power Supply
5V 15W 1
Phase
/ PMC-05V015W1AA
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (March 2013, Rev. 00)
9
Inrush Current
Inrush Current is the first surge current seen on the input side
when AC input is applied to the power supply. It is the first pulse
captured; see a typical picture for the inrush current as seen in
the power supply.
Dynamic Response
The power supply output voltage will remains within ±5% of its
steady state value, when subjected to a dynamic load from 0 to
100% of its rated current.
Overvoltage Protection
The power supply’s overvoltage circuit will be activated when its
internal feedback circuit fails. The output voltage shall not exceed
its specifications defined on Page 3 under “Protections”.
Overload & Overcurrent Protections
The power supply’s Overload (OLP) and Over current (OCP)
Protections will be activated when output current exceeds 120%
of I
O
(Max load). In such occurrence, the V
O
will start to droop and
once the power supply has reached its maximum power limit, the
protection is activated and the power supply will go into “Hiccup
mode” (Auto-Recovery). The power supply will recover once the
fault condition of the OLP and OCP is removed and I
O
is back
within the specifications.
Additionally, if the I
O
is < 120% but > 100% for a prolong period of
time (depending on the load), the Over Temperature Protection
(OTP) will be activated due to high temperature on critical
components. The power supply will then go into “Hiccup mode
until power supply cool down.
Over Temperature Protection
As mentioned above, the power supply also has Over
Temperature Protection (OTP). This is activated when the
overload condition persists for an extended duration and the
output current is below the overload trigger point but >100% load.
In the event of a higher operating condition at 100% load, the
power supply will run into OTP when the surrounding air
temperature is >80°C. When activated, the output voltage will go
into bouncing mode until the operating surrounding temperature
drops to 6C or output capacity is reduced as recommended in
the de-rating graph.
Short Circuit Protection
The power supply’s output OLP/OCP function also provides
protection against short circuits. When a short circuit is applied,
the output current will operate in “Hiccup mode”, as shown in the
illustration in the OLP/OCP section on this page. The power
supply will return to normal operation after the short circuit is
removed.
.

PMC-05V015W1AA

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies 5V, 15W, Panel Mount Enclosed/Term. Block
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet