MAX6775XKB+T

General Description
The MAX6775–MAX6781 low-power, 1%-accurate bat-
tery monitors are available in the ultra-small µDFN
package (1.0mm x 1.5mm) and SC70 packages. These
low-power devices are ideal for monitoring single lithi-
um-ion (Li+) cells, or multicell alkaline/NiCd/NiMH
power sources. These devices offer single (MAX6775/
MAX6776/MAX6777/MAX6778) or dual (MAX6779/
MAX6780/MAX6781) low-battery outputs and feature
fixed or resistor-adjustable hysteresis. Hysteresis elimi-
nates the output chatter sometimes associated with bat-
tery voltage monitors, usually due to input-voltage noise
or battery terminal voltage recovery after load removal.
These devices are available in several versions: with
single- or dual-voltage monitors, and with fixed or
adjustable hysteresis. The MAX6775/MAX6776 offer a
single battery monitor and factory-set hysteresis of
0.5%, 5%, or 10%. The MAX6779/MAX6780/MAX6781
have two battery monitors in a single package and fac-
tory-set hysteresis of 0.5%, 5%, or 10%. The MAX6777/
MAX6778 offer a single battery monitor with external
inputs for the rising and falling thresholds, allowing
external hysteresis control.
For convenient interface with system power circuitry or
microprocessors, both open-drain and push-pull out-
puts are available. The single-channel devices are
available with open-drain or push-pull outputs. The
dual-channel devices are available with both outputs
open-drain, both outputs push-pull, or one of each
(see the
Selector Guide
). This family of devices is
offered in small 5-pin SC70 and ultra-small 6-pin µDFN
packages, and is fully specified over the -40°C to
+85°C extended temperature range.
Applications
Battery-Powered Systems (Single-Cell Li+ or
Multicell NiMH, NiCd, Alkaline)
Cell Phones/Cordless Phones
Pagers
Portable Medical Devices
PDAs
Electronic Toys
MP3 Players
Features
o 1.0%-Accurate Threshold Specified Over
Temperature
o Single/Dual, Low-Battery Output Options
o Low 3µA Battery Current
o Open-Drain or Push-Pull Low-Battery Outputs
o Fixed or Adjustable Hysteresis
o Low-Input Leakage Current Allows Use of Large
Resistors
o Guaranteed Valid Low-Battery-Output Logic State
Down to V
BATT
= 1V
o Immune to Short Battery Transients
o Fully Specified from -40°C to +85°C
o Small 5-Pin SC70 or Ultra-Small 6-Pin µDFN
(1mm x 1.5mm) Package
MAX6775–MAX6781
Low-Power, 1%-Accurate Battery
Monitors in µDFN and SC70 Packages
________________________________________________________________
Maxim Integrated Products
1
Ordering Information
LBI
3.6V
LBO
BATT
MAX6775
SHDN OUT
DC-DC
CONVERTER
IN
Typical Operating Circuit
19-3774; Rev 4; 5/09
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,
or visit Maxim’s website at www.maxim-ic.com.
Ordering Information continued at end of data sheet.
+
Denotes a lead(Pb)-free/RoHS-compliant package.
T = Tape and reel.
MAX6775/MAX6776/MAX6779/MAX6780/MAX6781 are available
with factory-trimmed hysteresis. Specify trim by replacing “_”
with “A” for 0.5%, “B” for 5%, or “C” for 10% hysteresis.
Pin Configurations appear at end of data sheet.
PART TEMP RANGE PIN-PACKAGE
MAX6775XK_+T -40°C to +85°C 5 SC70
MAX6775LT_+T -40°C to +85°C 6 µDFN
MAX6776XK_+T -40°C to +85°C 5 SC70
MAX6776LT_+T -40°C to +85°C 6 µDFN
MAX6777XK+T -40°C to +85°C 5 SC70
MAX6777LT+T -40°C to +85°C 6 µDFN
MAX6775–MAX6781
Low-Power, 1%-Accurate Battery
Monitors in µDFN and SC70 Packages
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V
BATT
= 1.6V to 5.5V, T
A
= -40°C to +85°C, unless otherwise specified. Typical values are at T
A
= +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
BATT to GND............................................................-0.3V to +6V
LBI, LBL, LBH, LBI1, LBI2 to GND ...............-0.3V to minimum of
((V
BATT
+ 0.3V) and +6V)
LBO, LBO1, LBO2 to GND (open-drain) .................-0.3V to +6V
LBO, LBO1, LBO2 to GND (push-pull).........-0.3V to minimum of
((V
BATT
+ 0.3V) and +6V)
Input Current (all pins) ........................................................20mA
Output Current (all pins) .....................................................20mA
Continuous Power Dissipation (T
A
= +70°C)
5-Pin SC70 (derate 3.1mW/°C above +70°C)..............247mW
6-Pin µDFN (derate 2.1mW°C above +70°C) ..............168mW
Junction Temperature......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
T
A
= 0°C to +70°C 1.0 5.5
Operating Voltage Range
(Note 2)
V
BATT
T
A
= -40°C to +85°C 1.2 5.5
V
V
BATT
= 3.7V, no load 4 7
Supply Current I
Q
V
BATT
= 1.8V, no load 3.2 6
µA
FIXED HYSTERESIS (MAX6775/MAX6776/MAX6779/MAX6780/MAX6781)
0.5% hysteresis version 1.2037 1.2159 1.2280
5% hysteresis version 1.1493 1.1609 1.1725
LBI, LBI_ Falling Threshold
(Note 3)
V
LBIF
10% hysteresis version 1.0888 1.0998 1.1108
V
LBI Rising Threshold V
LBIR
1.2098 1.222 1.2342 V
LBI Input Leakage Current 0.2V V
LBI
V
BATT
- 0.2V -5 +5 nA
ADJUSTABLE HYSTERESIS (MAX6777/MAX6778)
LBL, LBH Threshold V
BATT
= 1.8V to 5.5V 1.2098 1.222 1.2342 V
LBL, LBH Input Leakage Current V
BATT
- 0.2V V
LBL/LBH
0.2V -5 +5 nA
MAX6775–MAX6781
Low-Power, 1%-Accurate Battery
Monitors in µDFN and SC70 Packages
_______________________________________________________________________________________ 3
ELECTRICAL CHARACTERISTICS (continued)
(V
BATT
= 1.6V to 5.5V, T
A
= -40°C to +85°C, unless otherwise specified. Typical values are at T
A
= +25°C.) (Note 1)
Note 1: Devices are tested at T
A
= +25°C and guaranteed by design for T
A
=T
MIN
to T
MAX
, as specified.
Note 2: Operating range ensures low-battery output is in the correct state. Minimum battery voltage for electrical specification is 1.6V.
Note 3: The rising threshold is guaranteed to be higher than the falling threshold.
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
LOW-BATTERY OUTPUTS (LBO, LBO1, LBO2)
Propagation Delay t
PD
V
LBI_
+ 100mV to V
LBI_
- 100mV 9 µs
Startup Time V
BATT
rising above 1.6V 3 ms
V
BATT
1.2V, I
SINK
= 100µA 0.3
V
BATT
2.7V, I
SINK
= 1.2mA 0.3
Output Low (Push-Pull or
Open-Drain)
V
OL
V
BATT
4.5V, I
SINK
= 3.2mA 0.3
V
V
BATT
1.6V, I
SOURCE
= 100µA
0.8 x
V
BATT
V
BATT
2.7V, I
SOURCE
= 500µA
0.8 x
V
BATT
Output High (Push-Pull ) V
OH
V
BATT
4.5V, I
SOURCE
= 800µA
0.8 x
V
BATT
V
Output Leakage Current
(Open-Drain)
Output not asserted, V
LBO_
= 5.5V -100 +100 nA
Typical Operating Characteristics
(T
A
= +25°C, unless otherwise noted.)
SUPPLY CURRENT
vs. TEMPERATURE
MAX6775 toc01
TEMPERATURE (°C)
SUPPLY CURRENT (µA)
603510-15
3.0
3.5
4.0
4.5
5.0
5.5
6.0
2.5
-40 85
V
BATT
= 5V
V
BATT
= 3.6V
V
BATT
= 3V
V
BATT
= 2.4V
V
BATT
= 1.6V
PROPAGATION DELAY
vs. TEMPERATURE
MAX6775 toc02
TEMPERATURE (°C)
PROPAGATION DELAY (µs)
603510-15
8
9
10
11
12
7
-40 85
V
BATT
= 5V
100mV OVERDRIVE
V
BATT
= 1.6V
MAXIMUM TRANSIENT DURATION
vs. THRESHOLD OVERDRIVE
MAX6775 toc03
THRESHOLD OVERDRIVE V
TH
- V
CC
(mV)
MAXIMUM TRANSIENT DURATION (µs)
10010
10
20
30
40
50
60
70
0
1 1000
OUTPUT ASSERTED ABOVE THIS LINE

MAX6775XKB+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Battery Management Single 1%-Accurate Battery Monitor
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union