MAX6775XKB+T

MAX6775–MAX6781
Low-Power, 1%-Accurate Battery
Monitors in µDFN and SC70 Packages
4 _______________________________________________________________________________________
Typical Operating Characteristics (continued)
(T
A
= +25°C, unless otherwise noted.)
NORMALIZED THRESHOLD VOLTAGES
vs. TEMPERATURE, MAX67__A
MAX6775 toc04
TEMPERATURE (°C)
THRESHOLD VOLTAGE (mV)
603510-15
-4
-3
-2
-1
0
1
-5
-40 85
NORMALIZED AT T
A
= +25°C
RISING
FALLING
NORMALIZED THRESHOLD VOLTAGES
vs. TEMPERATURE, MAX67__B
MAX6775 toc05
TEMPERATURE (°C)
THRESHOLD VOLTAGE (mV)
603510-15
-3
-2
-1
0
1
-4
-40 85
NORMALIZED AT T
A
= +25°C
RISING
FALLING
NORMALIZED THRESHOLD VOLTAGES
vs. TEMPERATURE, MAX67__C
MAX6775 toc06
TEMPERATURE (°C)
THRESHOLD VOLTAGE (mV)
603510-15
-2
-1
0
1
-3
-40 85
NORMALIZED AT T
A
= +25°C
RISING
FALLING
LBO OUTPUT VOLTAGE
vs. SINK CURRENT
MAX6775 toc07
SINK CURRENT (mA)
OUTPUT VOLTAGE (V)
12963
0.1
0.2
0.3
0.4
0.5
0
015
V
BATT
= 5.0V
V
BATT
= 1.8V
V
BATT
= 3.3V
LBO OUTPUT VOLTAGE
vs. SOURCE CURRENT
MAX6775 toc08
SOURCE CURRENT (mA)
OUTPUT VOLTAGE (V)
4321
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
1.0
05
V
BATT
= 5.0V
V
BATT
= 3.3V
V
BATT
= 1.8V
MAX6775–MAX6781
Low-Power, 1%-Accurate Battery
Monitors in µDFN and SC70 Packages
_______________________________________________________________________________________ 5
Pin Description
MAX6775/
MAX6776
MAX6777/
MAX6778
MAX6779/
MAX6780/
MAX6781
µDFN
SC70 µDFN SC70
µDFN
NAME FUNCTION
1 1 GND2
Reserved. Must be connected to GND. Do not use as the only
GND connection.
2 2 2 2 2 GND Ground
3 3 LBI
Low-Battery Input. Connect to the resistive divider to set the
trip level.
4444 LBO
Low-Battery Output, Active-Low. When V
LBI
/V
LBL
falls below
the falling threshold, LBO asserts. LBO deasserts when
V
LBI
/V
LBH
exceeds the rising threshold voltage.
5 5 N.C. No Connection. Not internally connected.
6 5 6 5 6 BATT Battery Input. Power supply to the device.
1 1 LBH
Rising-Trip-Level Input. Connect to a resistive divider to set the
rising trip level.
3 3 LBL
Falling-Trip-Level Input. Connect to a resistive divider to set the
falling trip level.
1 LBI2
Low-Battery Input 2. Connect to a resistive divider to set the
trip level.
3 LBI1
Low-Battery Input 1. Connect to a resistive divider to set the
trip level.
—— 4 LBO1
Low-Battery Output 1, Active-Low. When V
LBI1
falls below the
falling threshold voltage, LBO1 asserts. LBO1 deasserts when
V
LBI1
exceeds the rising threshold voltage. LBO1 is push-pull
on the MAX6779/MAX6781 and open-drain for the MAX6780.
—— 5 LBO2
Low-Battery Output 2, Active-Low. When V
LBI2
falls below the
falling threshold voltage, LBO2 asserts. LBO2 deasserts when
V
LBI2
exceeds the rising threshold voltage. LBO2 is open-drain
for the MAX6780/MAX6781 and push-pull for the MAX6779.
MAX6775–MAX6781
Detailed Description
These battery monitors have an active-low output that
asserts when the input falls below a set voltage. They
also offer hysteresis for noise immunity, and to remove
the possibility of output chatter due to battery terminal
voltage recovery after load removal. They are available
with one or two monitors per package, with push-pull or
open-drain outputs, and with internally set or externally
adjustable hysteresis (dual-channel devices offer only
internally fixed hysteresis). Figures 1, 2, and 3 show
block diagrams and typical connections. See the
Selector Guide
for details.
Low-Battery Output
All devices are offered with either push-pull or open-
drain outputs (see the
Selector Guide
). The MAX6781
has one push-pull output and one open-drain output,
configured as in Table 1.
On all devices with open-drain outputs an external
pullup resistor is required. The open-drain pullup resis-
tor can connect to an external voltage up to +6V,
regardless of the voltage at BATT.
Low-Power, 1%-Accurate Battery
Monitors in µDFN and SC70 Packages
6 _______________________________________________________________________________________
Table 1. MAX6781 Outputs
DEVICE LBO1 LBO2
MAX6781 Push-Pull Open-Drain
LBI1
LBO1
0
1
BATT
GND
V
REF
V
BATT
LBI2
LBO2
0
1
MAX6779
MAX6780
MAX6781
HYSTERESIS
CONTROL
Figure 2. Dual-Channel Fixed-Hysteresis Block Diagram
LBI
LBO
0
1
BATT
GND
R
L
V
REF
V
BATT
R
H
MAX6775
MAX6776
HYSTERESIS
CONTROL
Figure 1. Single-Channel Fixed-Hysteresis Block Diagram
LBL
LBO
0
1
LBH
BATT
GND
R
HYST
V
REF
V
BATT
R
H
R
L
MAX6777
MAX6778
Figure 3. Single-Channel Adjustable-Hysteresis Block Diagram

MAX6775XKB+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Battery Management Single 1%-Accurate Battery Monitor
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS