B58621K1510A067

Pressure Sensor
Transmitters
Series/Type: B58620L
The following products presented in this data sheet are being withdrawn.
Ordering Code Substitute Product Date of Withdrawal Deadline Last
Orders
Last Shipments
B58620L1110A053 2015-05-08 2015-08-31 2015-11-30
B58620L1110A052 2015-05-08 2015-08-31 2015-11-30
For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The
addresses of our worldwide sales network are presented at www.epcos.com/sales.
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Pressure sensors
Pressure transmitters for PCB mounting (voltage output) AC-T series
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 2 of 8
Important notes at the end of this document.
Description
The transmitters are based on piezoresistive silicon pressure sensors
from our own clean room.
The T-series electronic compensates nonlinearity and temperature
errors and supplies a precise calibrated output signal with a high
immunity against electromagnetic influences (EMI).
Features
Piezoresistive MEMS technology
Measured media (absolute pressure):
Air, non-aggressive gases (gas humidity 0 ... 85% r.h., without dew).
Unsuitable for substances, which react with glass, silicon, aluminum,
ceramics, polybutylene terephthalate, silicone glue or silicone gel.
Measured media (gauge pressure):
Air, non-aggressive gases (gas humidity 0 ... 100% r.h.)
and non-aggressive fluids.
Unsuitable for substances which react with glass, silicon, stainless
steel, silicone glue (p
r
10 bar) or epoxy glue (p
r
> 10 bar).
Voltage output proportional to pressure: 0.5 ... 4.5 V
RoHS-compatible, halogen-free
Dual-in-line package for PCB mounting
Dimensional drawings
Type LN for absolute pressure
(4.8 mm tube fitting)
Type KD for gauge pressure
(4.8 mm tube fitting)
Type KC for gauge pressure
(M5 thread connection)
All dimensions in mm
Pressure sensors
Pressure transmitters for PCB mounting (voltage output) AC-T series
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 3 of 8
Important notes at the end of this document.
Technical data
Absolute maximum ratings
Parameter Symbol Conditions Min. Typ. Max. Unit
Temperature ranges
Storage temperature range T
st
1)
–40 +105 °C
Operating temperature range T
a
2)
–25 +85 °C
Compensated temperature range T
c
3)
0 +70 °C
Soldering temperature T
solder
<5 s
(no reflow soldering)
+240 °C
Pressure ranges
Overpressure
p
ov
4), 5)
1.5 p
r
Supply voltage /-current
Supply voltage V
CC
6)
4.75 5.5 V
Supply current I
CC
I
A
= 0 7 mA
Signal output current I
A
7)
2 mA
Output signal at sensor failure V
ERR
0.01 V
DC break down voltage V
is
Types KD, KC only
8)
500 V
Parameter Symbol Conditions Min. Typ. Max. Unit
Output signal @ T
a
= 25°C, V
CC
= 5 V, I
A
< 0.1 mA
Offset V
A0
Simple output ACA, ACR
9)
0.485 0.5 0.515 V
Symmetrical output ACS
9)
2.485 2.5 2.515 V
Signal span (Full Scale) V
FS
10)
3.985 4.0 4.015 V
Nonlinearity L Simple output
10), 11)
±0.1 ±0.25
% FS
Symmetrical output
10), 11)
±0.25 ±0.5
% FS
Response time t
10-90
12)
1 ms
Supply voltage rejection SVR
10), 13)
±0.01
% FS/V
Parameter Symbol Conditions Min. Typ. Max. Unit
Data in temperature range @ T
a
= –25 ... 85 °C, V
CC
= 5 V, I
A
< 0.1 mA
Temperature hysteresis
14)
±0.1 ±0.5
% FS
Data in temperature range @ T
a
= 0 ... 70 °C, V
CC
= 5 V, I
A
< 0.1 mA
Temperature coefficient of offset TCV
A0
p
r
< 0.25 bar
15)
±0.015 ±0.05
% FS/K
p
r
0.25 bar
15)
±0.015 ±0.03
% FS/K
Temperature coefficient of span TCV
FS
16)
±0.015 ±0.03
% FS/K

B58621K1510A067

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Board Mount Pressure Sensors PRESSURE SENSOR ACR 6.000 KC V4 TN LD
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union