B58621K1510A067

Pressure sensors
Pressure transmitters for PCB mounting (voltage output) AC-T series
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 4 of 8
Important notes at the end of this document.
Characteristics
Simple output (ACA, ACR)
Symmetrical output (ACS)
Connection diagram
Terminal assignment Suggested drilling plan (top view)
Pin Symbol Signal
1 V
CC
Supply voltage
2 GND Ground
3 V
A
Output signal
4 - do not connect!
5 ... 8 - n.c.
Ø
0
,
8
7,62
14,6
1
4 5
8
V
A0
-p
r
+p
r
0
V
A0
+ ½V
V
A0
- ½V
FS
0 p
r
V
A0
+ V
FS
V
A0
p
V
A
U
V
cc
GND
Pressure sensors
Pressure transmitters for PCB mounting (voltage output) AC-T series
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 5 of 8
Important notes at the end of this document.
Rated pressures and ordering codes
Pressure
measurement
Absolute
(type LN)
Gauge
(type KD)
Gauge, symmetr.
(type KD)
Rated pressure p
r
bar
1.000
2.500
0.100
0.250
0.400
1.000
0.100
0.250
0.400
1.000
Product type
ACA 1.000 LN V4 TN L D
ACA 2.500 LN V4 TN L D
ACR 0.100 KD V4 TN L D
ACR 0.250 KD V4 TN L D
ACR 0.400 KD V4 TN L D
ACR 1.000 KD V4 TN L D
ACS 0.100 KD V4 TN L D
ACS 0.250 KD V4 TN L D
ACS 0.400 KD V4 TN L D
ACS 1.000 KD V4 TN L D
Ordering code
B58620L1110A052
B58620L1110A053
B58621K1110A054
B58621K1110A055
B58621K1110A056
B58621K1110A057
B58623K1110A058
B58623K1110A059
B58623K1110A060
B58623K1110A061
Pressure
measurement
Gauge
(type KC)
Gauge, symmetr.
(type KC)
Rated pressure p
r
bar
0.100
0.250
0.400
1.000
2.500
6.000
10.00
25.00
0.100
0.250
0.400
1.000
Product type
ACR 0.100 KC V4 TN L D
ACR 0.250 KC V4 TN L D
ACR 0.400 KC V4 TN L D
ACR 1.000 KC V4 TN L D
ACR 2.500 KC V4 TN L D
ACR 6.000 KC V4 TN L D
ACR 10.00 KC V4 TN L D
ACR 25.00 KC V4 TN L D
ACS 0.100 KC V4 TN L D
ACS 0.250 KC V4 TN L D
ACS 0.400 KC V4 TN L D
ACS 1.000 KC V4 TN L D
Ordering code
B58621K1510A062
B58621K1510A063
B58621K1510A064
B58621K1510A065
B58621K1510A066
B58621K1510A067
B58621K1510A068
B58621K1510A069
B58623K1510A070
B58623K1510A071
B58623K1510A072
B58623K1510A073
Other rated pressures upon request.
Pressure sensors
Pressure transmitters for PCB mounting (voltage output) AC-T series
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 6 of 8
Important notes at the end of this document.
Symbols and terms
1)
Storage temperature range T
st
A storage of the pressure sensor within the temperature range T
st,min
up to T
st,max
and without applied pressure and supply voltage will not affect the performance of the pressure sensor.
2)
Operating temperature range T
a
An operation of the pressure sensor within the temperature range T
a,min
up to T
a,max
will not affect the performance of the pressure sensor.
3)
Compensated temperature range T
c
While operating the pressure sensor within the temperature range T
c,min
up to T
c,max
,
the deviation of the output signal from the values at 25 °C will not exceed the temperature coefficients.
Out of the compensated temperature range, the deviations may increase.
4)
Rated pressure p
r
Within the rated pressure range 0 up to p
r
(symmetrical output: –p
r
up to +p
r
) the signal output characteristic corresponds
to this specification.
5)
Overpressure p
OV
Pressure cycles within the pressure range 0 up to p
ov
will not affect the performance of the pressure sensor.
6)
Supply voltage V
CC
V
CC,max
is the maximum permissible supply voltage, which can be applied without damages.
V
CC,min
is the minimum required supply voltage, which has to be applied for normal operation.
7)
Signal output current I
A
I
A,max
is the maximum permissible sink current of the signal output.
Exceeding (e.g. short circuit) may cause irreparable damages.
8)
DC break down voltage V
is
The pressure sensor withstands a high voltage between the stainless steel pressure connection and the electrical
connection V
CC
, V
A
and GND (all short circuited) without damage.
9)
Offset V
A0
The offset V
A0
is the signal output V
A
(p = 0) at zero pressure.
10)
Signal span (Full Scale)
Simple output: V
FS
= FS = V
A
(p
r
) – V
A0
Symmetrical output: V
FS
= FS = V
A
(+p
r
) – V
A
(–p
r
)
11)
Nonlinearity L (including pressure hysteresis)
The nonlinearity is the deviation of the real sensor characteristic V
A
= f(p) from the ideal straight line.
It can be approximated by a polynomial of second order, with the maximum at p
x
= p
r
/ 2 .
The equation to calculate the nonlinearity is:
r
x
0ArA
0AxA
p
p
V)p(V
V)p(V
L
=
12)
Response time t
10-90
Delay between a pressure change (10 ... 90% p
r
) and the corresponding signal output change (10 ... 90% FS).
13)
Supply voltage rejection SVR
While varying the supply voltage within the range V
CC,min
up to V
CC,max
at constant pressure and temperature,
the signal output change will not exceed SVR
max
.
14)
Temperature hysteresis
The temperature hysteresis is the change of offset, starting from the value at 25 °C after a temperature change
and return to 25 °C. Determined during temperature cycles in operating temperature range (cycles with 1 K/min).
15)
Temperature coefficient of offset TCV
A0
Offset at temperature T
x
: V
A0
(T
x
) = V
A0
(25 °C) + V
FS
(25 °C) · (T
x
– 25 °C) · TCV
A0
Values are valid within the compensated temperature range T
c,min
up to T
c,max
Out of the compensated temperature range, the deviation may increase.
16)
Temperature coefficient of span TCV
FS
Span at temperature T
x
: V
FS
(T
x
) = V
FS
(25 °C) · [ 1 + (T
x
– 25 °C) · TCV
FS
]
Values are valid within the compensated temperature range T
c,min
up to T
c,max
Out of the compensated temperature range, the deviation may increase.

B58621K1510A067

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Board Mount Pressure Sensors PRESSURE SENSOR ACR 6.000 KC V4 TN LD