5571D 1
IBS OPTOSUB-MA/M/R-LK-
OPC(-2MBD)
07/2001
Data Sheet 5571D
5 5 7 1 A 0 0 0
Function
The IBS OPTOSUB-MA/M/R-LK-OPC(-2MBD)
module converts the INTERBUS remote
interface to polymer fibers.
An INTERBUS controller board can be equipped
with an optical fiber interface using this
converter. Unlike other converters, this interface
can automatically control the optical
transmission power and provides improved bus
system diagnostics (optical path diagnostics).
The converter is a bus device, since it is
equipped with an INTERBUS protocol chip
(OPC).
Features
9-pos. D-SUB connector for plugging onto
the controller board
Optical fiber connection via F-SMA
connectors
500 kbaud or 2 Mbaud data transmission
rate
Optical path diagnostics
Extended diagnostic options
Voltage supply through the INTERBUS
interface
Supports paths with optical transmission
Please observe the Optical Fiber
Installation Guidelines
(DBGBIBSSYSFOCASSEMBLY).
Figure 1 IBS OPTOSUB-MA/M/R-LK-OPC
1 Diagnostic indicators
2 Threaded joint for the D-SUB connector
3 9-pos. D-SUB male connector
4 Connection for F-SMA connectors
1
4
3
5 5 7 1 A 0 0 1
2
Optical Fiber Converter
With a Data Transmission Rate of
500 kbaud or 2 Mbaud
IBS OPTOSUB-MA/M/R-LK-OPC(-2MBD)
2 5571D
Connector Pin Assignment
Incoming Remote Bus (9-pos. D-SUB))
Outgoing Remote Bus (F-SMA Connectors))
Figure 2 Position of the connectors
Pin Signal Designation
1 DO Data, sending direction
2 DI Data, receiving direction
3 GND GND (pin 3 and pin 4 internally
jumpered)
4GND
5 VCCI 5V DC supply, electrically
isolated (is only required for
RBST connector detection)
6 /DO Negated data, sending direction
7 /DI Negated data, receiving
direction
8 VCC 5 V DC supply
9 RBST Connector detection (pin 5 and
pin 9 are internally jumpered)
Connector Direction Wire Color
IN Receive data Black
OUT Send data Orange
5 5 7 1 A 0 0 3
O u t g o i n g r e m o t e b u s
R e m o t e O U T
I n c o m i n g
r e m o t e b u s
R e m o t e I N
I N
O U T
IBS OPTOSUB-MA/M/R-LK-OPC(-2MBD)
5571D 3
Local Diagnostic and Status Indicators
Des. Color Meaning
IB DIAG Green INTERBUS diagnostics
ON: Supply voltage present, bus active, no module error
Flashing
at 0.5 Hz:
Supply voltage present, bus not active
Flashing
at 2 Hz:
Supply voltage present, module error (bus can be active or not active)
OFF: Supply voltage not present
FO1 Yellow Status of the incoming optical fiber path
ON: If the previous device has optical path diagnostics, the system reserve of the
optical transmission has dropped.
OFF: Incoming optical fiber path is OK or the previous device does not have optical
path diagnostics.