DS1822
4 of 21
OPERATION—MEASURING TEMPERATURE
The core functionality of the DS1822 is its direct-to-digital temperature sensor. The resolution of the
temperature sensor is user-configurable to 9, 10, 11, or 12 bits, corresponding to increments of 0.5°C,
0.25°C, 0.125°C, and 0.0625°C, respectively. The default resolution at power-up is 12 bit. The DS1822
powers-up in a low-power idle state; to initiate a temperature measurement and A-to-D conversion, the
master must issue a Convert T [44h] command. Following the conversion, the resulting thermal data is
stored in the 2-byte temperature register in the scratchpad memory and the DS1822 returns to its idle
state. If the DS1822 is powered by an external supply, the master can issue “read-time slots” (see the 1-
WIRE BUS SYSTEM section) after the Convert T command and the DS1822 will respond by
transmitting 0 while the temperature conversion is in progress and 1 when the conversion is done. If the
DS1822 is powered with parasite power, this notification technique cannot be used since the bus must be
pulled high by a strong pullup during the entire temperature conversion. The bus requirements for parasite
power are explained in detail in the POWERING THE DS1822 section of this data sheet.
The DS1822 output temperature data is calibrated in degrees centigrade; for Fahrenheit applications, a
lookup table or conversion routine must be used. The temperature data is stored as a 16-bit sign-extended
two’s complement number in the temperature register (see Figure 2). The sign bits (S) indicate if the
temperature is positive or negative: for positive numbers S = 0 and for negative numbers S = 1. If the
DS1822 is configured for 12-bit resolution, all bits in the temperature register will contain valid data. For
11-bit resolution, bit 0 is undefined. For 10-bit resolution, bits 1 and 0 are undefined, and for 9-bit
resolution bits 2, 1 and 0 are undefined. Table 2 gives examples of digital output data and the
corresponding temperature reading for 12-bit resolution conversions.
TEMPERATURE REGISTER FORMAT Figure 2
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
LS Byte
2
3
2
2
2
1
2
0
2
-1
2
-2
2
-3
2
-4
bit 15 bit 14 bit 13 bit 12 bit 11 bit 10 bit 9 bit 8
MS Byte
S S S S S 2
6
2
5
2
4
TEMPERATURE/DATA RELATIONSHIP Table 2
TEMPERATURE
DIGITAL OUTPUT
(Binary)
DIGITAL OUTPUT
(Hex)
+125°C 0000 0111 1101 0000 07D0h
+85°C* 0000 0101 0101 0000 0550h
+25.0625°C 0000 0001 1001 0001 0191h
+10.125°C 0000 0000 1010 0010 00A2h
+0.5°C 0000 0000 0000 1000 0008h
0°C 0000 0000 0000 0000 0000h
-0.5°C 1111 1111 1111 1000 FFF8h
-10.125°C 1111 1111 0101 1110 FF5Eh
-25.0625°C 1111 1110 0110 1111 FE6Fh
-55°C 1111 1100 1001 0000 FC90h
*The power on reset value of the temperature register is +85°C
DS1822
5 of 21
OPERATION—ALARM SIGNALING
After the DS1822 performs a temperature conversion, the temperature value is compared to the user-
defined two’s complement alarm trigger values stored in the 1-byte T
H
and T
L
registers (see Figure 3).
The sign bit (S)
indicates if the value is positive or negative: for positive numbers S = 0 and for negative
numbers S = 1. The T
H
and T
L
registers are NV (EEPROM) so they will retain data when the device is
powered down. T
H
and T
L
can be accessed through bytes 2 and 3 of the scratchpad as explained in the
MEMORY section of this data sheet.
T
H
AND T
L
REGISTER FORMAT Figure 3
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
S 2
6
2
5
2
4
2
3
2
2
2
1
2
0
Only bits 11 through 4 of the temperature register are used in the T
H
and T
L
comparison since T
H
and T
L
are 8-bit registers. If the measured temperature is lower than or equal to T
L
or higher than or equal to T
H
,
an alarm condition exists and an alarm flag is set inside the DS1822. This flag is updated after every
temperature measurement; therefore, if the alarm condition goes away, the flag will be turned off after the
next temperature conversion.
The master device can check the alarm flag status of all DS1822s on the bus by issuing an Alarm Search
[ECh] command. Any DS1822s with a set alarm flag will respond to the command, so the master can
determine exactly which DS1822s have experienced an alarm condition. If an alarm condition exists and
the T
H
or T
L
settings have changed, another temperature conversion should be done to validate the alarm
condition.
POWERING THE DS1822
The DS1822 can be powered by an external supply on the V
DD
pin, or it can operate in “parasite power”
mode, which allows the DS1822 to function without a local external supply. Parasite power is very useful
for applications that require remote temperature sensing or that are very space constrained. Figure 1
shows the DS1822’s parasite-power control circuitry, which “steals” power from the 1-Wire bus via the
DQ pin when the bus is high. The stolen charge powers the DS1822 while the bus is high, and some of
the charge is stored on the parasite power capacitor (C
PP
) to provide power when the bus is low. When the
DS1822 is used in parasite power mode, the V
DD
pin must be connected to ground.
In parasite power mode, the 1-Wire bus and C
PP
can provide sufficient current to the DS1822 for most
operations as long as the specified timing and voltage requirements are met (refer to the DC
ELECTRICAL CHARACTERISTICS and the AC ELECTRICAL CHARACTERISTICS sections of this
data sheet). However, when the DS1822 is performing temperature conversions or copying data from the
scratchpad memory to EEPROM, the operating current can be as high as 1.5mA. This current can cause
an unacceptable voltage drop across the weak 1-Wire pullup resistor and is more current than can be
supplied by C
PP
. To assure that the DS1822 has sufficient supply current, it is necessary to provide a
strong pullup on the 1-Wire bus whenever temperature conversions are taking place or data is being
copied from the scratchpad to EEPROM. This can be accomplished by using a MOSFET to pull the bus
directly to the rail as shown in Figure 4. The 1-Wire bus must be switched to the strong pullup within
10μs (max) after a Convert T [44h] or Copy Scratchpad [48h] command is issued, and the bus must be
held high by the pullup for the duration of the conversion (t
conv
) or data transfer (t
wr
= 10ms). No other
activity can take place on the 1-Wire bus while the pullup is enabled.
The DS1822 can also be powered by the conventional method of connecting an external power supply to
the V
DD
pin, as shown in Figure 5. The advantage of this method is that the MOSFET pullup is not
required, and the 1-Wire bus is free to carry other traffic during the temperature conversion time.
DS1822
6 of 21
The use of parasite power is not recommended for temperatures above 100°C since the DS1822 may not
be able to sustain communications due to the higher leakage currents that can exist at these temperatures.
For applications in which such temperatures are likely, it is strongly recommended that the DS1822 be
powered by an external power supply.
In some situations the bus master may not know whether the DS1822s on the bus are parasite powered or
powered by external supplies. The master needs this information to determine if the strong bus pullup
should be used during temperature conversions. To get this information, the master can issue a Skip ROM
[CCh] command followed by a Read Power Supply [B4h] command followed by a “read-time slot”.
During the read time slot, parasite powered DS1822s will pull the bus low, and externally powered
DS1822s will let the bus remain high. If the bus is pulled low, the master knows that it must supply the
strong pullup on the 1-Wire bus during temperature conversions.
SUPPLYING THE PARASITE-POWERED DS1822 DURING TEMPERATURE
CONVERSIONS Figure 4
POWERING THE DS1822 WITH AN EXTERNAL SUPPLY Figure 5
64-BIT LASERED ROM CODE
Each DS1822 contains a unique 64–bit code (see Figure 6) stored in ROM. The least significant 8 bits of
the ROM code contain the DS1822’s 1-Wire family code: 22h. The next 48 bits contain a unique serial
number. The most significant 8 bits contain a cyclic redundancy check (CRC) byte that is calculated from
the first 56 bits of the ROM code. A detailed explanation of the CRC bits is provided in the CRC
GENERATION section. The 64-bit ROM code and associated ROM function control logic allow the
DS1822 to operate as a 1-Wire device using the protocol detailed in the 1-WIRE BUS SYSTEM section
of this data sheet.
64-BIT LASERED ROM CODE Figure 6
8-BIT CRC 48-BIT SERIAL NUMBER 8-BIT FAMILY CODE (22h)
MSB MSB LSB LSB LSBMSB
V
DD
(External Supply)
DS1822
GND
V
DD
DQ
V
PU
4.7k
To Other
1-Wire Devices
1-Wire Bus
Micro-
processor
V
PU
V
PU
4.7k
1-Wire Bus
Micro-
processor
DS1822
GND
V
DD
DQ
To Other
1-Wire Devices

DS1822Z

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Board Mount Temperature Sensors
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet