MCP3905/06
DS21948D-page 16 © 2007 Microchip Technology Inc.
The high-frequency output HF
OUT
has lower
integration times and, thus, higher frequencies. The
output frequency value can be calculated with the
following equation:
EQUATION 4-2: HF
OUT
FREQUENCY
OUTPUT EQUATION
The constant HF
C
depends on the F
OUT0
and F
OUT1
digital settings with the Table 4-4.
The detailed timings of the output pulses are described
in the Timing Characteristics table (see Section 1.0
“Electrical Characteristics” and Figure 1-1).
MINIMAL OUTPUT FREQUENCY FOR
NO-LOAD THRESHOLD
The MCP3905/06 also includes, on each output
frequency, a no-load threshold circuit that will eliminate
any creep effects in the meter. The outputs will not
show any pulse if the output frequency falls below the
no-load threshold. The minimum output frequency on
F
OUT0/1
and HF
OUT
is equal to 0.0015% of the
maximum output frequency (respectively F
C
and HF
C
)
for each of the F2, F1 and F0 selections (see Table 4-3
and Table 4-4); except when F2, F1, F0 = 011. In this
last configuration, the no-load threshold feature is
disabled. The selection of F
C
will determine the start-up
current load. In order to respect the IEC standards
requirements, the meter will have to be designed to
allow start-up currents compatible with the standards
by choosing the FC value matching these
requirements. For additional applications information
on no-load threshold, startup current and other meter
design points, refer to AN994, "IEC Compliant Active
Energy Meter Design Using The MCP3905/6”,
(DS00994).
TABLE 4-4: OUTPUT FREQUENCY CONSTANT HF
C
FOR HF
OUT
(V
REF
=2.4V)
HF
OUT
Hz()
8.06 V
0
× V
1
G×× HF
C
×
V
REF
()
2
----------------------------------------------------------------
=
Where:
V
0
= the RMS differential voltage on Channel 0
V
1
= the RMS differential voltage on Channel 1
G=the PGA gain on Channel 0
(current channel)
F
C
= the frequency constant selected
V
REF
= the voltage reference
F2 F1 F0 HF
C
HF
C
(Hz)
HF
C
(Hz)
(MCLK = 3.58 MHz)
HF
OUT
Frequency (Hz) with
full-scale AC Inputs
000 64 x F
C
MCLK/2
15
109.25 27.21
001 32 x F
C
MCLK/2
15
109.25 27.21
010 16 x F
C
MCLK/2
15
109.25 27.21
0112048 x F
C
MCLK/2
7
27968.75 6070.12
100128 x F
C
MCLK/2
16
219.51 47.42
101 64 x F
C
MCLK/2
16
219.51 47.42
110 32 x F
C
MCLK/2
16
219.51 47.42
111 16 x F
C
MCLK/2
16
219.51 47.42
© 2007 Microchip Technology Inc. DS21948D-page 17
MCP3905/06
5.0 APPLICATIONS INFORMATION
5.1 Meter Design using the
MCP3905/06
For all applications information, refer to AN994, "IEC
Compliant Active Energy Meter Design Using The
MCP3905/6” (DS00994). This application note
includes all required energy meter design information,
including the following:
Meter rating and current sense choices
Shunt design
PGA selection
F2, F1, F0 selection
Meter calibration
Anti-aliasing filter design
Compensation for parasitic shunt inductance
EMC design
Power supply design
No-load threshold
Start-up current
Accuracy testing results from MCP3905-based
meter
EMC testing results from MCP3905-based meter
MCP3905/06
DS21948D-page 18 © 2007 Microchip Technology Inc.
6.0 PACKAGING INFORMATION
6.1 Package Marking Information
Legend: XX...X Customer-specific information
Y Year code (last digit of calendar year)
YY Year code (last 2 digits of calendar year)
WW Week code (week of January 1 is week ‘01’)
NNN Alphanumeric traceability code
Pb-free JEDEC designator for Matte Tin (Sn)
* This package is Pb-free. The Pb-free JEDEC designator ( )
can be found on the outer packaging for this package.
Note: In the event the full Microchip part number cannot be marked on one line, it will
be carried over to the next line, thus limiting the number of available
characters for customer-specific information.
3
e
3
e
XXXXXXXXXXX
YYWWNNN
24-Lead SSOP
Examples:
XXXXXXXXXXX
MCP3905
0739256
I/SS^^
3
e

MCP3906-I/SS

Mfr. #:
Manufacturer:
Description:
IC ENERGY METERING 24SSOP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet