† See “Notes” following AC Electrical Characteristics tables.
AC Electrical Characteristics - 1.544 MHz Input to 1.544 MHz Output Jitter Transfer
Characteristics Sym Min Max Units Conditions/Notes
1 Jitter attenuation for 1 Hz@20 UIpp input 0 6 dB 1-3,6,9-14,
21-22,24,29,36
2 Jitter attenuation for 1 Hz@104 UIpp input 6 16 dB 1-3,6,9-14,
21-22,24,29,36
3 Jitter attenuation for 10 Hz@20 UIpp input 12 22 dB 1-3,6,9-14,
21-22,24,29,36
4 Jitter attenuation for 60 Hz@20 UIpp input 28 38 dB 1-3,6,9-14,
21-22,24,29,36
5 Jitter attenuation for 300 Hz@20 UIpp input 42 dB 1-3,6,9-14,
21-22,24,29,36
6 Jitter attenuation for 10 kHz@0.3 UIpp input 45 dB 1-3,6,9-14,
21-22,24,29,36
7 Jitter attenuation for 100 kHz@0.3 UIpp input 45 dB 1-3,6,9-14,
21-22,24,29,36
MT9043 Data Sheet
26
Zarlink Semiconductor Inc.
† See “Notes” following AC Electrical Characteristics tables.
AC Electrical Characteristics - 2.048 MHz Input to 2.048 MHz Output Jitter Transfer
Characteristics Sym. Min. Max. Units Conditions/Notes
1 Jitter at output for 1 Hz@3.00 UIpp input
with 40 Hz to 100 kHz filter
2.9 UIpp 1-3,7,9-14,
21-22,24,30,36
2 0.09 UIpp 1-3,7,9-14,
21-22,24,30,37
3 Jitter at output for 3 Hz@2.33 UIpp input
with 40 Hz to 100 kHz filter
1.3 UIpp 1-3,7,9-14,
21-22,24,30,36
4 0.10 UIpp 1-3,7,9-14,
21-22,24,30,37
5 Jitter at output for 5 Hz@2.07 UIpp input
with 40 Hz to 100 kHz filter
0.80 UIpp 1-3,7,9-14,
21-22,24,30,36
6 0.10 UIpp 1-3,7,9-14,
21-22,24,30,37
7 Jitter at output for 10 Hz@1.76 UIpp input
with 40 Hz to 100 kHz filter
0.40 UIpp 1-3,7,9-14,
21-22,24,30,36
8 0.10 UIpp 1-3,7,9-14,
21-22,24,30,37
9 Jitter at output for 100 Hz@1.50 UIpp input
with 40 Hz to 100 kHz filter
0.06 UIpp 1-3,7,9-14,
21-22,24,30,36
10 0.05 UIpp 1-3,7,9-14,
21-22,24,30,37
11 Jitter at output for 2400 Hz@1.50 UIpp input
with 40 Hz to 100 kHz filter
0.04 UIpp 1-3,7,9-14,
21-22,24,30,36
12 0.03 UIpp 1-3,7,9-14,
21-22,24,30,37
13 Jitter at output for 100 kHz@0.20 UIpp input
with 40 Hz to 100 kHz filter
0.04 UIpp 1-3,7,9-14,
21-22,24,30,36
14 0.02 UIpp 1-3,7,9-14,
21-22,24,30,35
MT9043 Data Sheet
27
Zarlink Semiconductor Inc.
† See “Notes” following AC Electrical Characteristics tables.
† See “Notes” following AC Electrical Characteristics tables.
† See “Notes” following AC Electrical Characteristics tables.
AC Electrical Characteristics - 8 kHz Input Jitter Tolerance
Characteristics Sym. Min. Max. Units Conditions/Notes
1 Jitter tolerance for 1 Hz input 0.80 UIpp 1-3,5,9 -14,21-22,24-26,28
2 Jitter tolerance for 5 Hz input 0.70 UIpp 1-3,5,9 -14,21-22,24-26,28
3 Jitter tolerance for 20 Hz input 0.60 UIpp 1-3,5,9 -14,21-22,24-26,28
4 Jitter tolerance for 300 Hz input 0.20 UIpp 1-3,5,9 -14,21-22,24-26,28
5 Jitter tolerance for 400 Hz input 0.15 UIpp 1-3,5,9 -14,21-22,24-26,28
6 Jitter tolerance for 700 Hz input 0.08 UIpp 1-3,5,9 -14,21-22,24-26,28
7 Jitter tolerance for 2400 Hz input 0.02 UIpp 1-3,5,9 -14,21-22,24-26,28
8 Jitter tolerance for 3600 Hz input 0.01 UIpp 1-3,5,9 -14,21-22,24-26,28
AC Electrical Characteristics - 1.544 MHz Input Jitter Tolerance
Characteristics Sym. Min. Max. Units Conditions/Notes
1 Jitter tolerance for 1 Hz input 150 UIpp 1-3,6,9 -14,21-22,24-26,29
2 Jitter tolerance for 5 Hz input 140 UIpp 1-3,6,9 -14,21-22,24-26,29
3 Jitter tolerance for 20 Hz input 130 UIpp 1-3,6,9 -14,21-22,24-26,29
4 Jitter tolerance for 300 Hz input 35 UIpp 1-3,6,9 -14,21-22,24-26,29
5 Jitter tolerance for 400 Hz input 25 UIpp 1-3,6,9 -14,21-22,24-26,29
6 Jitter tolerance for 700 Hz input 15 UIpp 1-3,6,9 -14,21-22,24-26,29
7 Jitter tolerance for 2400 Hz input 4 UIpp 1-3,6,9 -14,21-22,24-26,29
8 Jitter tolerance for 10 kHz input 1 UIpp 1-3,6,9 -14,21-22,24-26,29
9 Jitter tolerance for 100 kHz input 0.5 UIpp 1-3,6,9 -14,21-22,24-26,29
AC Electrical Characteristics - 2.048 MHz Input Jitter Tolerance
Characteristics Sym. Min. Ma.x Units Conditions/Notes
1 Jitter tolerance for 1 Hz input 150 UIpp 1-3,7,9 -14,21-22,24-26,30
2 Jitter tolerance for 5 Hz input 140 UIpp 1-3,7,9 -14,21-22,24-26,30
3 Jitter tolerance for 20 Hz input 130 UIpp 1-3,7,9 -14,21-22,24-26,30
4 Jitter tolerance for 300 Hz input 50 UIpp 1-3,7,9 -14,21-22,24-26,30
5 Jitter tolerance for 400 Hz input 40 UIpp 1-3,7,9 -14,21-22,24-26,30
6 Jitter tolerance for 700 Hz input 20 UIpp 1-3,7,9 -14,21-22,24-26,30
7 Jitter tolerance for 2400 Hz input 5 UIpp 1-3,7,9 -14,21-22,24-26,30
8 Jitter tolerance for 10 kHz input 1 UIpp 1-3,7,9 -14,21-22,24-26,30
9 Jitter tolerance for 100 kHz input 1 UIpp 1-3,7,9 -14,21-22,24-26,30