ADuM1200-EP Data Sheet
Rev. B | Page 8 of 16
PACKAGE CHARACTERISTICS
Table 4.
Parameter Symbol Min Typ Max Unit Test Conditions
Resistance (Input-to-Output)
1
I-O
Capacitance (Input-to-Output)
1
C
I-O
1.0 pF f = 1 MHz
Input Capacitance C
I
4.0 pF
IC Junction-to-Case Thermal Resistance, Side 1 θ
JCI
46 °C/W
Thermocouple located at
center of package underside
IC Junction-to-Case Thermal Resistance, Side 2 θ
JCO
41 °C/W
1
The device is considered a 2-terminal device; Pin 1, Pin, 2, Pin 3, and Pin 4 are shorted together, and Pin 5, Pin 6, Pin 7, and Pin 8 are shorted together.
REGULATORY INFORMATION
The ADuM1200-EP is approved by the organizations listed in Table 5. See Table 10 for details regarding recommended maximum
working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
Recognized Under 1577 Component
Recognition Program
1
Approved under CSA Component Acceptance
Notice #5A
Certified according to DIN V VDE
V 0884-10 (VDE V 0884-10): 2006-12
2
Single/Basic 2500 V rms Isolation Voltage
Basic insulation per CSA 60950-1-03 and
IEC 60950-1, 400 V rms (566 peak) maximum
working voltage
Functional insulation per CSA 60950-1-03 and
IEC 60950-1, 800 V rms (1131 V peak) maximum
working voltage
Reinforced insulation, 560 V peak
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM1200UR-EP is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection
limit = 5 µA).
2
In accordance with DIN V VDE V 0884-10, each ADuM1200UR-EP is proof tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial discharge
detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 2500 V rms 1 minute duration
Clearance in the Plane of the PCB CL
PCB
4.5 mm min
Measured from input terminals to output terminals,
shortest line of sight distance through air in the
plane of the PCB
Minimum External Air Gap (Clearance) L(I01) 4.0 mm min
Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 4.0 mm min
Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 mm min Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index)
DIN IEC 112/VDE 0303 Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1)