M27W401 DC and AC parameters
13/23
4 DC and AC parameters
T
A
= –40 to 85°C; V
CC
= 2.7V to 3.6V; V
PP
= V
CC
T
A
= 25 °C; V
CC
= 6.25V ± 0.25V; V
PP
= 12.75V ± 0.25V
Table 5. Read Mode DC Characteristics
(1)
1. V
CC
must be applied simultaneously with or before V
PP
and removed simultaneously or after V
PP
.
Symbol Parameter Test Condition Min. Max. Unit
I
LI
Input Leakage Current 0V ≤
V
IN
≤ V
CC
±10 µA
I
LO
Output Leakage Current 0V ≤ V
OUT
≤ V
CC
±10 µA
I
CC
Supply Current
E
= V
IL
, G = V
IL
, I
OUT
= 0mA,
f = 5MHz, V
CC
≤
3.6V
15 mA
I
CC1
Supply Current (Standby) TTL E = V
IH
1mA
I
CC2
Supply Current (Standby)
CMOS
E
> V
CC
– 0.2V, V
CC
≤
3.6V 15 µA
I
PP
Program Current V
PP
= V
CC
100 µA
V
IL
Input Low Voltage –0.6 0.2V
CC
V
V
IH
(2)
2. Maximum DC voltage on Output is V
CC
+0.5V.
Input High Voltage 0.7V
CC
V
CC
+ 0.5 V
V
OL
Output Low Voltage I
OL
= 2.1mA 0.4 V
V
OH
Output High Voltage TTL I
OH
= –400µA 2.4 V
Table 6. Programming Mode DC Characteristics
(1)
1. V
CC
must be applied simultaneously with or before V
PP
and removed simultaneously or after V
PP
.
Symbol Parameter Test Condition Min Max Unit
I
LI
Input Leakage Current 0 ≤ V
IN
≤ V
CC
±10 µA
I
CC
Supply Current 50 mA
I
PP
Program Current E = V
IL
50 mA
V
IL
Input Low Voltage –0.3 0.8 V
V
IH
Input High Voltage 2.0 V
CC
+ 0.5 V
V
OL
Output Low Voltage I
OL
= 2.1 mA 0.4 V
V
OH
Output High Voltage TTL I
OH
= –400 µA 2.4 V
V
ID
A9 Voltage 11.5 12.5 V
Obsolete Product(s) - Obsolete Product(s)