DC and AC parameters M27W401
16/23
T
A
= 25 °C; V
CC
= 6.25V ± 0.25V; V
PP
= 12.75V ± 0.25V
Figure 9. Programming and Verify Modes AC Waveforms
Table 10. Programming Mode AC Characteristics
(1)
Symbol Alt Parameter Test Condition Min. Max. Unit
t
AVPL
t
AS
Address Valid to Program Low 2 µs
t
QVPL
t
DS
Input Valid to Program Low 2 µs
t
VPHPL
t
VPS
V
PP
High to Program Low 2 µs
t
VCHPL
t
VCS
V
CC
High to Program Low 2 µs
t
ELPL
t
CES
Chip Enable Low to Program Low 2 µs
t
PLPH
t
PW
Program Pulse Width 95 105 µs
t
PHQX
t
DH
Program High to Input Transition 2 µs
t
QXGL
t
OES
Input Transition to Output Enable Low 2 µs
t
GLQV
t
OE
Output Enable Low to Output Valid 100 ns
t
GHQZ
(2)
t
DFP
Output Enable High to Output Hi-Z 0 130 ns
t
GHAX
t
AH
Output Enable High to Address Transition 0 ns
1. V
CC
must be applied simultaneously with or before V
PP
and removed simultaneously or after V
PP
.
2. Sampled only, not 100% tested.
tAVPL
VALID
AI00725
A0-A18
Q0-Q7
V
PP
V
CC
G
DATA IN DATA OUT
E
tQVEL
tVPHEL
tVCHEL
tEHQX
tELEH
tGLQV
tQXGL
tGHQZ
tGHAX
PROGRAM
VERIFY
Obsolete Product(s) - Obsolete Product(s)