ARXP1224

RX (ARX)
ORDERING INFORMATION
TYPES
Standard packing: 50 pcs. in an inner package; 500 pcs. in an outer package
3 GHz SMALL
MICROWAVE RELAY
RX RELAYS (ARX)
Nominal coil
voltage
Part No.
Single side stable 1 coil latching 2 coil latching
3 V DC ARX1003 ARX1103 ARX1203
4.5V DC ARX104H ARX114H ARX124H
6 V DC ARX1006 ARX1106 ARX1206
9 V DC ARX1009 ARX1109 ARX1209
12 V DC ARX1012 ARX1112 ARX1212
24 V DC ARX1024 ARX1124 ARX1224
FEATURES
1. Excellent high frequency
characteristics (~2.5GHz, Impedance
50)
2. Small size
• Size: 20.5(L) × 12.4(W) × 9.4(H) mm
.807(L) × .488(W) × .370(H) inch
3. High sensitivity
• Nominal operating power: 200 mW
4. Infrequent switching type is also
available. Please inquire.
TYPICAL APPLICATIONS
• Cellular phone base station
• Cellular phone-related measurement
devices (SP3T/SP4T switches, etc)
• Wireless LAN
• Wireless Local Loop
If you wish to use in applications with low
level loads or with high frequency
switching, please consult us.
Compliance with RoHS Directive
Frequency to 2.5GHz
V. S.W.R. (Max.) 1.2
Insertion loss (dB, Max.) 0.2
Isolation (dB, Min.) 60
0.4
0.5
0
0.1
0.3
0.2
300kHz 1.5GHz 2.5GHz3GHz
COM-NC
COM-NO
Insertion loss, dB
Frequency
Contact arrangement
1: 1 Form C
RX relays
ARX 1
Operating function
0: Single side stable
1: 1 coil latching
2: 2 coil latching
Coil voltage (DC)
03: 3V, 4H: 4.5V, 06: 6V, 09: 9V, 12: 12V, 24: 24V
(H=0.5)
MicrowaveDevices.book Page 53 Wednesday, November 26, 2008 7:50 PM
All Rights Reserved © C
OPYRIGHT Panasonic Electric Works Co., Ltd.
RX (ARX)
RATING
1. Coil data
1) Single side stable
2) 1 coil latching type
3) 2 coil latching type
2. Specifications
Note: * The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT
in GENERAL APPLICATION GUIDELINES.
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 60°C 140°F)
3 V DC
75%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
66.7mA 45
200mW
110%V of nominal
voltage
4.5V DC 44.4mA 101
6 V DC 33.3mA 180
9 V DC 22.2mA 405
12 V DC 16.7mA 720
24 V DC 8.3mA 2,880
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 60°C 140°F)
3 V DC
75%V or less of
nominal voltage
(Initial)
75%V or less of
nominal voltage
(Initial)
66.7mA 45
200mW
110%V of nominal
voltage
4.5V DC 44.4mA 101
6 V DC 33.3mA 180
9 V DC 22.2mA 405
12 V DC 16.7mA 720
24 V DC 8.3mA 2,880
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 60°C 140°F)
3 V DC
75%V or less of
nominal voltage
(Initial)
75%V or less of
nominal voltage
(Initial)
133.3mA 22.5
400mW
110%V of nominal
voltage
4.5V DC 88.9mA 50.6
6 V DC 66.7mA 90
9 V DC 44.4mA 202.5
12 V DC 33.3mA 360
24 V DC 16.7mA 1,440
Characteristics Item Specifications
Contact
Arrangement 1 Form C
Contact material Stationary: Gold plating, Movable: Gold clad
Initial contact resistance, max. Max. 100m
(By voltage drop 10V AC 10mA)
Rating
Contact rating 10W (2.5GHz, Impedance 50
, V.S.W.R. 1.2) 10mA 24V DC (resistive load)
Contact carrying power Max. 20W (at 2.5GHz, Impedance 50
, V.S.W.R. 1.2, Average)
Max. switching voltage 30V DC
Max. switching current 0.5A DC
Nominal
operating
power
Single side stable 200mW
1 coil latching 200mW
2 coil latching 400mW
High frequency
characteristics
(Initial) (~2.5GHz,
Impedance 50
)
V. S.W.R. (Return loss) Max. 1.2 (Min. 20.8dB)
Insertion loss Max. 0.2dB
Isolation Min. 60dB
Input power Max. 20W (at 40°C, V.S.W.R. 1.2, Average)
Electrical
characteristics
Insulation resistance (Initial)
Min. 100M
(at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown
voltage
(Initial)
Between open contacts 500 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 1,000 Vrms for 1min. (Detection current: 10mA)
Between contact and earth terminal 500 Vrms for 1min. (Detection current: 10mA)
Temperature rise (at 20°C)
Max. 60°C (By resistive method, nominal voltage applied to the coil: Contact carrying
power: 20W, at 2.5GHz, Impedance 50
, V.S.W.R. 1.2)
Operate time [Set time] (at 20°C)
Max. 10ms (Approx. 6ms) [Max. 10ms (Approx. 5ms)] (Nominal operating voltage applied
to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C)
Max. 6ms (Approx. 3ms) [Max. 10ms (Approx. 5ms)] (Nominal operating voltage applied to
the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock
resistance
Functional Min. 200 m/s
2
{20 G} (Half-wave pulse of sine wave: 11ms; detection time: 10
µ
s.)
Destructive Min. 1,000m/s
2
{100 G} (Half-wave pulse of sine wave: 6ms.)
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 3mm (Detection time: 10
µ
s.)
Destructive 10 to 55 Hz at double amplitude of 5mm
Expected life
Mechanical Min. 5
×
10
6
(at 180 cpm)
Electrical
Min. 10
5
(10W 2.5 GHz, Impedance 50
, V.S.W.R. 1.2)
Min. 3
×
10
5
(10mA 24V DC resistive load)
Conditions Conditions for operation, transport and storage*
Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 5 g .18 oz
MicrowaveDevices.book Page 54 Wednesday, November 26, 2008 7:50 PM
All Rights Reserved © C
OPYRIGHT Panasonic Electric Works Co., Ltd.
RX (ARX)
REFERENCE DATA
1. High frequency characteristics
Sample: ARX1012
Measuring method: Measured with HP network analyzer (HP8753C).
The details for the high frequency characteristics and the measurement
procedures and conditions are listed in the RX relay test report.
DIMENSIONS
(mm inch)
V.S.W.R. (Return loss) • Insertion loss • Isolation
40
50
0
10
30
20
300kHz 1.5GHz 2.5GHz 3GHz
COM-NO
5.0
2.0
1.5
1.2
1.1
COM-NC
Return loss, dB
Frequency
V.S.W.R.
0.4
0.5
0
0.1
0.3
0.2
300kHz 1.5GHz 2.5GHz3GHz
COM-NC
COM-NO
Insertion loss, dB
Frequency
80
100
0
20
60
40
300kHz 1.5GHz 2.5GHz 3GHz
COM-NC
COM-NO
Isolation, dB
Frequency
The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac
Schematic (Bottom view)
Tolerance: ±0.1 ±.004
General tolerance: ±0.3 ±.012
(Reset condition)
PC board pattern (Bottom view)
(Reset condition)(Deenergized condition)
(2.74)
(.108)
(2.04)
(.080)
2.54
.100
2-0.6×0.3
2-.024×.012
7-0.40 to 0.45 dia.
7-.016 to .018 dia.
2.63
.104
Solder to the PC board earth.
9.2
.362
0.2
.008
3.0
.118
20.5
.807
12.4
.488
0.9 dia hole
.035 dia hole
7.62
.300
2.54
.100
7.62
.300
0.90
.035
(2 coil latching type only)
R 0.45
71
14 13 12 11 10 9 8
NC
COM
NO
71
891011121314
RESET COM SET
1
7
6
89101112
1314
RESET COM SET
Single side stable 1 coil latching 2 coil latching
Direction indication
Direction indication
Direction indication
CAD Data
MicrowaveDevices.book Page 55 Wednesday, November 26, 2008 7:50 PM
All Rights Reserved © C
OPYRIGHT Panasonic Electric Works Co., Ltd.

ARXP1224

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
General Purpose Relays SMALL MICROWAVE RELAY
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union