ARXP1224

RX (ARX)
NOTES
1. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. lf it includes ripple, the ripple
factor should be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different. The nominal operating voltage
should be applied to the coil for more
than 30 ms to set/reset the latching type
relay.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or
malfunction.
3. External magnetic field
Since RX relays are highly sensitive
polarized relays, their characteristics will
be affected by a strong external magnetic
field. Avoid using the relay under that
condition.
4. Cleaning
For automatic cleaning, the boiling
method is recommended. Avoid
ultrasonic cleaning which subjects the
relays to high frequency vibrations, which
may cause the contacts to stick.
lt is recommended that a fluorinated
hydrocarbon or other alcoholic solvents
be used.
5. Soldering
The manual soldering shall be performed
under following condition.
Max. 260°C 500°F 10s
Max. 350°C 662°F 3s
In addition, when soldering the case to
the PC board, the plating may swell
depending on the soldering conditions.
6. Conditions for operation, transport
and storage conditions
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage of the relay:
(1) Temperature:
–40 to +70°C –40 to +158°F
(2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
(3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage:
2) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
3) Freezing
Condensation or other moisture may
freeze on the relay when the temperature
is lower than 0°C 32°F. This causes
problems such as sticking of movable
parts or operational time lags.
4) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
7. Latching relay
In order to assure proper operating
regardless of changes in the ambient
usage temperature and usage conditions,
nominal operating voltage should be
applied to the coil for more than 30 ms to
set/reset the latching type relay.
Humidity, %RH
Temperature, °C °F
Tolerance range
85
5
0
+32
70
+158
–40
–40
(Avoid freezing
when used at
temperatures lower
than 0°C 32°F
(Avoid
condensation
when used at
temperatures higher
than 0°C 32°F
For general cautions for use, please
refer to the “General Application
Guidelines”.
MicrowaveDevices.book Page 56 Wednesday, November 26, 2008 7:50 PM
All Rights Reserved © C
OPYRIGHT Panasonic Electric Works Co., Ltd.

ARXP1224

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
General Purpose Relays SMALL MICROWAVE RELAY
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union