Parameter Device Symbol Min Typ Max Unit
Remote On/Off Signal Interface
(V
IN
=V
IN, min
to V
IN, max
; open collector or equivalent,
Signal referenced to V
IN-
terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low Specification
Remote On/Off Current – Logic Low All I
on/off
0.15 1.0 mA
On/Off Voltage:
Logic Low All V
on/off
0.0
1.2 V
Logic High – (Typ = Open Collector) All V
on/off
__ 15 V
Logic High maximum allowable leakage current All I
on/off
50 A
Turn-On Delay and Rise Times
(I
O
=I
O, max
)
T
delay
= Time until V
O
= 10% of V
O,set
from either
application of Vin with Remote On/Off set to On or
operation of Remote On/Off from Off to On with Vin
already applied for at least one second.
3.3V
T
delay
2.5
ms
T
rise
12
ms
2.5V – 1.2V
T
delay
2.5
ms
T
rise
= time for V
O
to rise from 10% of V
O,set
to 90% of
V
O,set
.
T
rise
1.5
ms
Output Voltage Adjustment
(See Feature Descriptions):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (trim)
V
sense
__
90
__
__
10
110
%V
o,nom
%V
o,nom
Output Overvoltage Protection
3.3V V
O, limit
4.0
4.9 V
2.5V
3.0
3.4 V
1.8V
2.1
2.4 V
1.5V
1.8
2.2 V
1.2V
1.5
1.8 V
Overtemperature Protection
All T
ref
110
°C
(See Feature Descriptions)
Input Undervoltage Lockout V
IN, UVLO
Turn-on Threshold All
34.5 36 V
Turn-off Threshold All
30 32
V
GE
Data Sheet
QPW050/060 Series Power Modules; DC-DC converters
36-75Vdc Input; 1.2Vdc to 3.3Vdc Output
October 5, 2015 ©2012 General Electric Company. All rights reserved. Page 5
Characteristic Curves
The following figures provide typical characteristics for the QPW050A0F (3.3V, 50A) at 25ºC. The figures are identical for
either positive or negative Remote On/Off logic.
INPUT CURRENT, I
i
(A)
OUTPUT VOLTAGE, On/Off VOLTAGE
V
O
(V) (5V/div) V
ON/OFF
(V) (2V/div)
INPUT VOLTAGE, V
O
(V) TIME, t (5 ms/div)
Figure 1. Typical Input Characteristic at Room
Temperature.
Figure 4. Typical Start-Up Using Remote On/Off, negative
logic version shown.
EFFCIENCY, (%)
OUTPUT CURRENT, OUTPUT VOLTAGE
I
O
(A) (10A/div) V
O
(V) (100mV/div)
OUTPUT CURRENT, I
O
(A) TIME, t (100 s/div)
Figure 2. Typical Converter Efficiency Vs. Output current at
Room Temperature.
Figure 5. Typical Transient Response to Step
change in Load from 50% to 25% of
Full Load at Room Temperature and 48
Vdc Input.
OUTPUT VOLTAGE,
V
O
(V) (50mV/div)
OUTPUT CURRENT, OUTPUT VOLTAGE
I
O
(A) (10A/div) V
O
(V) (100mV/div)
TIME, t (1s/div)
TIME, t (100 s/div)
Figure 3. Typical Output Ripple and Noise at Room
Temperature and I
o
= I
o, max
.
Figure 6. Typical Transient Response to Step change in
Load from 50% to 75% of Full Load at Room Temperature
and 48 Vdc Input.
36 Vin
48 Vin
75 Vin
0
1
2
3
4
5
6
25 35 45 55 65 75
Io = 0 A
Io = 25 A
Io = 50 A
80
82
84
86
88
90
92
94
0 1020304050
Vi = 36 V
Vi = 48 V
Vi = 75 V
GE
Data Sheet
QPW050/060 Series Power Modules; DC-DC converters
36-75Vdc Input; 1.2Vdc to 3.3Vdc Output
October 5, 2015 ©2012 General Electric Company. All rights reserved. Page 6
Characteristic Curves
The following figures provide typical characteristics for the QPW060A0G (2.5V, 60A) at 25ºC. The figures are identical for
either positive or negative Remote On/Off logic.
INPUT CURRENT, I
i
(A)
OUTPUT VOLTAGE, On/Off VOLTAGE
V
O
(V) (5V/div) V
ON/OFF
(V) (1V/div)
INPUT VOLTAGE, V
O
(V) TIME, t (2.5 ms/div)
Figure 7. Typical Input Characteristic at Room
Temperature.
Figure 10. Typical Start-Up Using Remote On/Off, negative
logic version shown.
EFFCIENCY, (%)
OUTPUT CURRENT, OUTPUT VOLTAGE
I
O
(A) (10A/div) V
O
(V) (50mV/div)
OUTPUT CURRENT, I
O
(A) TIME, t (500 s/div)
Figure 8. Typical Converter Efficiency Vs. Output current at
Room Temperature.
Figure 11. Typical Transient Response to Step
change in Load from 50% to 25%of Full Load at
Room Temperature and 48 Vdc Input.
OUTPUT VOLTAGE,
V
O
(V) (50mV/div)
OUTPUT CURRENT, OUTPUT VOLTAGE
I
O
(A) (10A/div) V
O
(V) (50mV/div)
TIME, t (2.5s/div)
TIME, t (500 s/div)
Figure 9. Typical Output Ripple and Noise at Room
Temperature and I
o
= I
o, max
.
Figure 12. Typical Transient Response to Step change in
Load from 50% to 75% of Full Load at Room Temperature
and 48 Vdc Input.
36 Vin
48 Vin
75 Vin
0
1
2
3
4
5
6
25 35 45 55 65 75
Io = 60A
Io = 0 A
Io = 30 A
84
86
88
90
92
94
5 1015202530354045505560
Vi = 36 V
Vi = 48 V
Vi = 75 V

QPW060A0P1Z

Mfr. #:
Manufacturer:
Description:
DC DC CONVERTER 1.2V 72W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: