V
DD
= 3.3V, GND = 0V, EN = V
DD
, 100mA load or I
FORWARD
and 10µF C
OUT
on OUT, T
A
= -40°C to +125°C, unless otherwise noted.
Typical values are at +25°C.
Typical Operating Characteristics (continued)
0
25
50
75
100
0 250 500 750 1000
FORWARD VOLTAGE (mV)
FORWARD CURRENT (mA)
FORWARD VOLTAGE vs. FORWARD CURRENT
(WLP)
toc03e
V
DD
= 5.5V
Refer to Figure 1 for Test Setup Conditions
V
DD
= 5.5V
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
0
50
100
150
200
250
0 250 500 750 1000
FORWARD VOLTAGE (mV)
FORWARD CURRENT (mA)
FORWARD VOLTAGE vs. FORWARD CURRENT
(SOT)
toc03f
V
DD
= 5.5V
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Thermal Limit Reached
Refer to Figure 1 for Test Setup Conditions
V
DD
= 5.5V
0
50
100
150
200
250
300
0 250 500 750 1000
FORWARD VOLTAGE (mV)
FORWARD CURRENT (mA)
FORWARD VOLTAGE vs. FORWARD CURRENT
(SOT)
toc03d
V
DD
= 3.3V
Refer to Figure 1 for Test Setup Conditions
V
DD
= 3.3V
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Themal Limit Reached
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
0 1 2 3 4 5 6
CATHODE CURRENT (µA)
VOUT (V)
CATHODE CURRENT
AT REVERSE OPERATION
toc04
V
DD
= 0V
I
CATHODE
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Refer to Figure 2 for Test Setup Conditions
-0.5
0
0.5
1
1.5
2
2.5
3
0 1 2 3 4 5 6
ANODE CURRENT (μ A)
VOUT (V)
ANODE CURRENT
AT REVERSE OPERATION
toc05
V
DD
= 0V
I
ANODE
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Refer to Figure 2 for Test Setup Conditions
-0.5
0
0.5
1
1.5
2
2.5
0 1 2 3 4 5 6
GROUND CURRENT (µA)
VOUT (V)
GROUND CURRENT
AT REVERSE OPERATION
toc06
V
DD
= 0V
I
GND
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Refer to Figure 2 for Test Setup Conditions
-0.1
-0.05
0
0.05
0.1
0.15
0.2
-40 -25 -10 5 20 35 50 65 80 95 110 125
INPUT CURRENT INTO VIN (µA)
TEMPERATURE (°C)
ANODE CURRENT
AT REVERSE OPERATION
toc07
V
DD
= 3.3V
V
OUT
-V
DD
= 0.1V
Refer to Figure 2 for Test Setup Conditions
MAX40200 Ultra-Tiny Micropower, 1A Ideal Diode
with Ultra-Low Voltage Drop
Maxim Integrated
│
5
www.maximintegrated.com