V
DD
= 3.3V, GND = 0V, EN = V
DD
, 100mA load or I
FORWARD
and 10µF C
OUT
on OUT, T
A
= -40°C to +125°C, unless otherwise noted.
Typical values are at +25°C.
0
10
20
30
40
50
60
70
0 200 400 600 800 1000
GROUND CURRENT (μ A)
FORWARD/LOAD CURRENT(mA)
GROUND CURRENT
vs. FORWARD/LOAD CURRENT
toc02a
Refer to Figure 1 for Test Setup Conditions
V
DD
= 1.5V
T
A
= 25°C
T
A
= 125°C
T
A
= -40°C
T
A
= 85°C
0
25
50
75
0 200 400 600 800 1000
GROUND CURRENT (μ A)
FORWARD/LOAD CURRENT(mA)
GROUND CURRENT
vs. FORWARD/LOAD CURRENT
toc02b
V
DD
= 3.3V
Refer to Figure 1 for Test Setup Conditions
V
DD
= 3.3V
T
A
= 25°C
T
A
= 125°C
T
A
= -40°C
T
A
= 85°C
0
4
8
12
16
20
24
0 1 2 3 4 5 6
QUIESCENT SUPPLY CURRENT (
μ A)
SUPPLY INPUT VOLTAGE (V)
QUIESCENT SUPPLY CURRENT
vs. SUPPLY INPUT VOLTAGE
toc01
T
A
= 25°C
T
A
= 125°C
T
A
= -40°C
T
A
= 85°C
Refer to Figure 1 for Test Setup Conditions
I
FWD/LOAD
= 0mA
0
25
50
75
100
0 200 400 600 800 1000
GROUND CURRENT (µA)
FORWARD/LOAD CURRENT(mA)
GROUND CURRENT
vs. FORWARD/LOAD CURRENT
toc02c
Refer to Figure 1 for Test Setup Conditions
V
DD
= 5.5V
T
A
= 25°C
T
A
= 125°C
T
A
= -40°C
T
A
= 85°C
0
100
200
300
400
0 250 500 750 1000
FORWARD VOLTAGE (mV)
FORWARD CURRENT (mA)
FORWARD VOLTAGE vs. FORWARD CURRENT
(WLP)
toc03a
V
DD
= 1.5V
T
A
= -40°C
T
A
= 25°C
Refer to Figure 1 for Test Setup Conditions
V
DD
= 1.5V
T
A
= 85°C
T
A
= 125°C
Thermal Limit Reached
0
100
200
300
400
500
600
700
0 250 500 750 1000
FORWARD VOLTAGE (mV)
FORWARD CURRENT (mA)
FORWARD VOLTAGE vs. FORWARD CURRENT
(SOT)
toc03b
V
DD
= 1.5V
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Themal Limit Reached
Refer to Figure 1 for Test Setup Conditions
0
25
50
75
100
125
150
0 250 500 750 1000
FORWARD VOLTAGE (mV)
FORWARD CURRENT (mA)
FORWARD VOLTAGE vs. FORWARD CURRENT
(WLP)
toc03c
V
DD
= 3.3V
Refer to Figure 1 for Test Setup Conditions
V
DD
= 3.3V
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
MAX40200 Ultra-Tiny Micropower, 1A Ideal Diode
with Ultra-Low Voltage Drop
Maxim Integrated
4
www.maximintegrated.com
Typical Operating Characteristics
V
DD
= 3.3V, GND = 0V, EN = V
DD
, 100mA load or I
FORWARD
and 10µF C
OUT
on OUT, T
A
= -40°C to +125°C, unless otherwise noted.
Typical values are at +25°C.
Typical Operating Characteristics (continued)
0
25
50
75
100
0 250 500 750 1000
FORWARD VOLTAGE (mV)
FORWARD CURRENT (mA)
FORWARD VOLTAGE vs. FORWARD CURRENT
(WLP)
toc03e
V
DD
= 5.5V
Refer to Figure 1 for Test Setup Conditions
V
DD
= 5.5V
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
0
50
100
150
200
250
0 250 500 750 1000
FORWARD VOLTAGE (mV)
FORWARD CURRENT (mA)
FORWARD VOLTAGE vs. FORWARD CURRENT
(SOT)
toc03f
V
DD
= 5.5V
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Thermal Limit Reached
Refer to Figure 1 for Test Setup Conditions
V
DD
= 5.5V
0
50
100
150
200
250
300
0 250 500 750 1000
FORWARD VOLTAGE (mV)
FORWARD CURRENT (mA)
FORWARD VOLTAGE vs. FORWARD CURRENT
(SOT)
toc03d
V
DD
= 3.3V
Refer to Figure 1 for Test Setup Conditions
V
DD
= 3.3V
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Themal Limit Reached
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
0 1 2 3 4 5 6
CATHODE CURRENT (µA)
VOUT (V)
CATHODE CURRENT
AT REVERSE OPERATION
toc04
V
DD
= 0V
I
CATHODE
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Refer to Figure 2 for Test Setup Conditions
-0.5
0
0.5
1
1.5
2
2.5
3
0 1 2 3 4 5 6
ANODE CURRENT (μ A)
VOUT (V)
ANODE CURRENT
AT REVERSE OPERATION
toc05
V
DD
= 0V
I
ANODE
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Refer to Figure 2 for Test Setup Conditions
-0.5
0
0.5
1
1.5
2
2.5
0 1 2 3 4 5 6
GROUND CURRENT (µA)
VOUT (V)
GROUND CURRENT
AT REVERSE OPERATION
toc06
V
DD
= 0V
I
GND
T
A
= -40°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
Refer to Figure 2 for Test Setup Conditions
-0.1
-0.05
0
0.05
0.1
0.15
0.2
-40 -25 -10 5 20 35 50 65 80 95 110 125
INPUT CURRENT INTO VIN (µA)
TEMPERATURE (°C)
ANODE CURRENT
AT REVERSE OPERATION
toc07
V
DD
= 3.3V
V
OUT
-V
DD
= 0.1V
Refer to Figure 2 for Test Setup Conditions
MAX40200 Ultra-Tiny Micropower, 1A Ideal Diode
with Ultra-Low Voltage Drop
Maxim Integrated
5
www.maximintegrated.com
V
DD
= 3.3V, GND = 0V, EN = V
DD
, 100mA load or I
FORWARD
and 10µF C
OUT
on OUT, T
A
= -40°C to +125°C, unless otherwise noted.
Typical values are at +25°C.
0
0.5
1
1.5
2
2.5
3
-40 -25 -10 5 20 35 50 65 80 95 110 125
OUTPUT CURRENT FROM VOUT (µA)
TEMPERATURE (°C)
CATHODE CURRENT
AT REVERSE OPERATION
toc08
V
DD
= 0V
V
OUT
= 5.5V
Refer to Figure 2 for Test Setup Conditions
ENABLE TRANSIENT
I
FWD
= 1A
2V/div
1V/div
10µs/div
V(EN)
V
OUT
3.3V
C
LOAD
= 4.7µF
3.3V
toc10a
DISABLE TRANSIENT
I
FWD
= 1A
2V/div
1V/div
100µs/div
V(EN)
V
OUT
3.3V
C
LOAD
= 4.7µF
3.3V
toc11a
POWER-UP DELAY
2V/div
1V/div
20µs/div
VDD
V
OUT
3.3V
R
LOAD
= 3.3k
3.3V
toc9
ENABLE TRANSIENT
I
FWD
= 100mA
2V/div
1V/div
10µs/div
V(EN)
V
OUT
3.3V
C
LOAD
= 4.7µF
3.3V
toc10b
DISABLE TRANSIENT
I
FWD
= 100mA
2V/div
1V/div
400µs/div
V(EN)
V
OUT
3.3V
C
LOAD
= 4.7µF
3.3V
toc11b
MAX40200 Ultra-Tiny Micropower, 1A Ideal Diode
with Ultra-Low Voltage Drop
Maxim Integrated
6
www.maximintegrated.com
Typical Operating Characteristics (continued)

MAX40200ANS+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Supervisory Circuits Current Sense/Ideal Diode
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet