Spec No. JEFL243E-0007J-01 9/10
MURATA MFG.CO.,LTD
(4) Reworking with Soldering iron
The following conditions shall be strictly followed when using a soldering iron after
being mounted by flow or reflow soldering.
· Pre-heating: 150°C, 1 min · Soldering iron output: 30W max.
· Tip temperature: 350°C max. · Tip diameter:φ3mm max.
· Soldering time : 3(+1,-0) seconds. · Times : 2times max.
Notes : Do not touch the products directly with the soldering iron.
(5) Solder Volume
Solder shall be used not to be exceeded the upper limits as shown below.
Accordingly increasing the solder volume, the mechanical stress to product is also increased.
Excessive solder volume may cause the failure of mechanical or electrical performance.
16.8 Cleaning Conditions
Products shall be cleaned on the following conditions.
(1) Cleaning temperature shall be limited to 60°C max. (40°C max. for Isopropyl alcohol.)
(2) Ultrasonic cleaning shall comply with the following conditions, avoiding the resonance phenomenon
at the mounted products and P.C.B..
Power : 20W/ l max.
Frequency : 28kHz to 40kHz
Time : 5 minutes max.
(3) Cleaner
1. Alternative cleaner Isopropyl alcohol (IPA)
2. Aqueous agent PINE ALPHA ST-100S
(4) There shall be no residual flux and residual cleaner after cleaning.
In the case of using aqueous agent, products shall be dried completely after rinse with de-ionized
water in order to remove the cleaner.
(5) Other cleaning
Please contact us.
16.9 Handling of a substrate
After mounting products on a substrate, do not apply any stress to the product caused by bending or twisting to
the substrate when cropping the substrate, inserting and removing a connector from the substrate or tightening
screw to the substrate.
Excessive mechanical stress may cause cracking in the product.
Bending Twisting
16.10 Operating Environment
Do not use this product under the following environmental conditions, on deterioration
of the performance, such as insulation resistance may result from the use.
(1) in corrosive gases (acidic gases, alkaline gases, chlorine, sulfur gases, organic gases and etc.)
(2) in the atmosphere where liquid such as organic solvent, may splash on the products.
U
er Limit
U
er Limit
Recommendable
Recommendable
1/3 T ≦ t ≦ T (T : Chip thickness)