MT9042C Data Sheet
28
Zarlink Semiconductor Inc.
Figure 21 - Input Controls Setup and Hold Timing
† See "Notes" following AC Electrical Characteristics tables.
† See "Notes" following AC Electrical Characteristics tables.
† See "Notes" following AC Electrical Characteristics tables
AC Electrical Characteristics - Intrinsic Jitter Unfiltered
Characteristics Sym. Min. Max. Units Conditions/Notes†
1 Intrinsic jitter at F8o (8 kHz) 0.0002 UIpp 1-14,21-24,28
2 Intrinsic jitter at F0o
(8 kHz) 0.0002 UIpp 1-14,21-24,28
3 Intrinsic jitter at F16o
(8 kHz) 0.0002 UIpp 1-14,21-24,28
4 Intrinsic jitter at C1.5o (1.544 MHz) 0.030 UIpp 1-14,21-24,29
5 Intrinsic jitter at C2o (2.048 MHz) 0.040 UIpp 1-14,21-24,30
6 Intrinsic jitter at C3o
(3.088 MHz) 0.060 UIpp 1-14,21-24,31
7 Intrinsic jitter at C4o
(4.096 MHz) 0.080 UIpp 1-14,21-24,32
8 Intrinsic jitter at C8o (8.192 MHz) 0.160 UIpp 1-14,21-24,33
9 Intrinsic jitter at C16o
(16.384 MHz) 0.320 UIpp 1-14,21-24,34
AC Electrical Characteristics - C1.5o (1.544 MHz) Intrinsic Jitter Filtered
Characteristics Sym. Min. Max. Units Conditions/Notes†
1 Intrinsic jitter (4 Hz to 100 kHz filter) 0.015 UIpp 1-14,21-24,29
2 Intrinsic jitter (10 Hz to 40 kHz filter) 0.010 UIpp 1-14,21-24,29
3 Intrinsic jitter (8 kHz to 40 kHz filter) 0.010 UIpp 1-14,21-24,29
4 Intrinsic jitter (10 Hz to 8 kHz filter) 0.005 UIpp 1-14,21-24,29
AC Electrical Characteristics - C2o (2.048 MHz) Intrinsic Jitter Filtered
Characteristics Sym. Min. Max. Units Conditions/Notes†
1 Intrinsic jitter (4 Hz to 100 kHz filter) 0.015 UIpp 1-14,21-24,30
2 Intrinsic jitter (10 Hz to 40 kHz filter) 0.010 UIpp 1-14,21-24,30
3 Intrinsic jitter (8 kHz to 40 kHz filter) 0.010 UIpp 1-14,21-24,30
4 Intrinsic jitter (10 Hz to 8 kHz filter) 0.005 UIpp 1-14,21-24,30
t
H
t
S
F8o
MS1,2
LOS1,2
RSEL, GTi
V
T
V
T
MT9042C Data Sheet
29
Zarlink Semiconductor Inc.
† See "Notes" following AC Electrical Characteristics tables.
† See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - 8 kHz Input to 8 kHz Output Jitter Transfer
Characteristics Sym. Min. Max. Units Conditions/Notes†
1 Jitter attenuation for 1 Hz@0.01 UIpp input 0 6 dB 1-3,6,9-14,21-22,24,28,35
2 Jitter attenuation for 1 Hz@0.54 UIpp input 6 16 dB 1-3,6,9-14,21-22,24,28,35
3 Jitter attenuation for 10 Hz@0.10 UIpp input 12 22 dB 1-3,6,9-14,21-22,24,28,35
4 Jitter attenuation for 60 Hz@0.10 UIpp input 28 38 dB 1-3,6,9-14,21-22,24,28,35
5 Jitter attenuation for 300 Hz@0.10 UIpp input 42 dB 1-3,6,9-14,21-22,24,28,35
6 Jitter attenuation for 3600 Hz@0.005 UIpp input 45 dB 1-3,6,9-14,21-22,24,28,35
AC Electrical Characteristics - 1.544 MHz Input to 1.544 MHz Output Jitter Transfer
Characteristics Sym. Min. Max. Units Conditions/Notes†
1 Jitter attenuation for 1 Hz@20 UIpp input 0 6 dB 1-3,7,9-14,21-22,24,29,35
2 Jitter attenuation for 1 Hz@104 UIpp input 6 16 dB 1-3,7,9-14,21-22,24,29,35
3 Jitter attenuation for 10 Hz@20 UIpp input 12 22 dB 1-3,7,9-14,21-22,24,29,35
4 Jitter attenuation for 60 Hz@20 UIpp input 28 38 dB 1-3,7,9-14,21-22,24,29,35
5 Jitter attenuation for 300 Hz@20 UIpp input 42 dB 1-3,7,9-14,21-22,24,29,35
6 Jitter attenuation for 10 kHz@0.3 UIpp input 45 dB 1-3,7,9-14,21-22,24,29,35
7 Jitter attenuation for 100 kHz@0.3 UIpp input 45 dB 1-3,7,9-14,21-22,24,29,35
MT9042C Data Sheet
30
Zarlink Semiconductor Inc.
† See "Notes" following AC Electrical Characteristics tables.
† See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - 2.048 MHz Input to 2.048 MHz Output Jitter Transfer
Characteristics Sym. Min. Max. Units Conditions/Notes†
1 Jitter at output for 1 Hz@3.00 UIpp input 2.9 UIpp 1-3,8,9-14,21-22,24,30,35
2 with 40 Hz to 100 kHz filter 0.09 UIpp 1-3,8,9-14,21-22,24,30,36
3 Jitter at output for 3 Hz@2.33 UIpp input 1.3 UIpp 1-3,8,9-14,21-22,24,30,35
4 with 40 Hz to 100 kHz filter 0.10 UIpp 1-3,8,9-14,21-22,24,30,36
5 Jitter at output for 5 Hz@2.07 UIpp input 0.80 UIpp 1-3,8,9-14,21-22,24,30,35
6 with 40 Hz to 100 kHz filter 0.10 UIpp 1-3,8,9-14,21-22,24,30,36
7 Jitter at output for 10 Hz@1.76 UIpp input 0.40 UIpp 1-3,8,9-14,21-22,24,30,35
8 with 40 Hz to 100 kHz filter 0.10 UIpp 1-3,8,9-14,21-22,24,30,36
9 Jitter at output for 100 Hz@1.50 UIpp input 0.06 UIpp 1-3,8,9-14,21-22,24,30,35
10 with 40 Hz to 100 kHz filter 0.05 UIpp 1-3,8,9-14,21-22,24,30,36
11 Jitter at output for 2400 Hz@1.50 UIpp input 0.04 UIpp 1-3,8,9-14,21-22,24,30,35
12 with 40 Hz to 100 kHz filter 0.03 UIpp 1-3,8,9-14,21-22,24,30,36
13 Jitter at output for 100 kHz@0.20 UIpp input 0.04 UIpp 1-3,8,9-14,21-22,24,30,35
14 with 40 Hz to 100 kHz filter 0.02 UIpp 1-3,8,9-14,21-22,24,30,36
AC Electrical Characteristics - 8 kHz Input Jitter Tolerance
Characteristics Sym. Min. Max. Units Conditions/Notes†
1 Jitter tolerance for 1 Hz input 0.80 UIpp 1-3,6,9-14,21-22,24-26,28
2 Jitter tolerance for 5 Hz input 0.70 UIpp 1-3,6,9-14,21-22,24-26,28
3 Jitter tolerance for 20 Hz input 0.60 UIpp 1-3,6,9-14,21-22,24-26,28
4 Jitter tolerance for 300 Hz input 0.20 UIpp 1-3,6,9-14,21-22,24-26,28
5 Jitter tolerance for 400 Hz input 0.15 UIpp 1-3,6,9-14,21-22,24-26,28
6 Jitter tolerance for 700 Hz input 0.08 UIpp 1-3,6,9-14,21-22,24-26,28
7 Jitter tolerance for 2400 Hz input 0.02 UIpp 1-3,6,9-14,21-22,24-26,28
8 Jitter tolerance for 3600 Hz input 0.01 UIpp 1-3,6,9-14,21-22,24-26,28