Solder Reow Prole
Recommended reow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The ACPL-M51L is approved by the following organizations:
UL Approval under UL 1577, component recognition program up to V
ISO
= 3750 V
RMS
File E55361.
CSA Approval under CSA Component Acceptance Notice #5, File CA 88324.
IEC/EN/DIN EN 60747-5-5 (Option 060E only)
Insulation and Safety Related Specications
Parameter Symbol ACPL-M51L Units Conditions
Minimum External
Air Gap (Clearance)
L(101) 5 mm Measured from input terminals to output terminals, shortest distance
through air.
Minimum External
Tracking (Creepage)
L(102) 5 mm Measured from input terminals to output terminals, shortest distance
path along body.
Minimum Internal
Plastic Gap
(Internal Clearance)
0.08 mm Through insulation distance conductor to conductor, usually the
straight line distance thickness between the emitter and detector.
Tracking Resistance
(Comparative Tracking
Index)
CTI 175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060E)
Description
Symbol Characteristic Unit
ACPL-M51L
Installation classication per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 V
rms
for rated mains voltage ≤ 300 V
rms
for rated mains voltage ≤ 600 V
rms
I – IV
I – III
I – II
Climatic Classication 55/105/21
Pollution Degree (DIN VDE 0110/39) 2
Maximum Working Insulation Voltage V
IORM
567 Vpeak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec, Partial discharge < 5 pC
V
PR
1050 Vpeak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test, t
m
= 10 sec, Partial discharge < 5 pC
V
PR
896 Vpeak
Highest Allowable Overvoltage (Transient Overvoltage t
ini
= 60 sec) V
IOTM
6000 Vpeak
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current**
Output Power**
T
S
I
S, INPUT
P
S, OUTPUT
150
150
600
°C
mA
mW
Insulation Resistance at TS, V
IO
= 500 V R
S
>10
9
Ω
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section,
(IEC/EN/DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test proles.
** Refer to the following gure for dependence of P
S
and I
S
on ambient temperature.